Measurement basis
Transferred charge depends on current and elapsed time when that physical relationship applies. A charge conversion does not supply the current or duration separately.
Definition conventions
Ah and mAh measure charge. Expressing energy in Wh also requires voltage.
Conversion method
Use the compatible charge-unit factors and retain whether the source is coulombs, ampere-hours or a prefixed form.
Choose the conversion direction
Confirm the source charge label before choosing the receiving charge unit.
The coulomb and the elementary charge
Electric charge is the property of matter that produces electromagnetic forces. The SI unit is the coulomb (C), named after Charles-Augustin de Coulomb, and one coulomb is the charge moved by a current of one ampere in one second. Since the 2019 redefinition of the SI the numerical value of the elementary charge is fixed at exactly 1.602176634 × 10⁻¹⁹ C, so one coulomb corresponds to about 6.241509 × 10¹⁸ elementary charges. That makes the electron charge a defined constant and the ampere and coulomb derived from it. A static spark of a few nanocoulombs involves about 10¹⁰ electrons, and the charge in a lightning flash involves more than 10²⁰.
Ampere-hours and milliamp-hours
Batteries are rated in ampere-hours (Ah) or milliampere-hours (mAh), which are units of charge, not energy. One ampere-hour is 3,600 C, since an ampere for an hour is 3,600 ampere-seconds, and one milliampere-hour is 3.6 C. A phone cell rated 4,000 mAh therefore holds 14,400 C. To find energy, multiply by the voltage: at a nominal 3.85 V, 4.0 Ah gives 15.4 Wh, which is 55.4 kJ. Two batteries with the same mAh but different voltages hold different energy, so a power bank advertised at 20,000 mAh is built from 3.7 V cells, and delivering 5 V output takes conversion losses. Charge capacity alone does not tell how long a device will run.
Small charges in static electricity and capacitors
Charges in everyday electronics are small. Shuffling across a carpet can leave a person with a few tens of nanocoulombs to microcoulombs of charge, which discharges as a spark of a few kilovolts. The charge stored in a capacitor is Q = C × V, so 100 µF at 12 V holds 1.2 mC, and a 10 nF capacitor at 5 V holds 50 nC. Particle detectors measure charges down to picocoulombs, and one picocoulomb equals about 6.24 million elementary charges. At the opposite end, a femtocoulomb is 10⁻¹⁵ C, or roughly 6,241 electrons. Prefixes bridge these scales: 1 C equals 10³ mC, 10⁶ µC, 10⁹ nC and 10¹² pC.
Lightning and large charge transfers
Cloud-to-ground lightning transfers charge measured in coulombs. A single return stroke typically moves a few coulombs, and a complete flash with several strokes and continuing current often moves tens of coulombs, though figures vary widely between storms. Electroplating and electrolysis plants handle charge in kilocoulombs and larger: depositing one mole of a singly charged metal takes one Faraday of charge, 96,485.33212 C, a value now exact because the elementary charge and the Avogadro constant are both fixed. Converting 96,485 C to ampere-hours gives about 26.8 Ah. The kilocoulomb, at 1,000 C, is a natural unit for these processes, and each kilocoulomb equals about 0.2778 Ah, or 277.8 mAh.
Charge stored in a cell versus charge that moves
A battery rating counts the charge that the cell can deliver between full and empty under stated conditions, which is smaller than the total charge of all the electrons inside it. A 2,500 mAh cell rated at a 0.5 A discharge delivers 9,000 C, and 5 A would give less because internal losses rise at higher current. Charging reverses the flow, and the charge returned is usually somewhat more than the charge extracted, so a coulomb counter shows coulombic efficiency of about 99 percent for good lithium-ion cells. If you track capacity in a log, record ampere-hours with the current and temperature in the same row. Converting mAh to coulombs makes it simple to compare against a current drawn over a number of seconds, such as a 30 second radio transmission at 200 mA, which uses 6 C or 1.67 mAh.
Charge and current are related by time
Current is the rate of flow of charge, I = Q/t, so a charge of 120 C moved in 40 s corresponds to an average current of 3 A. The inverse is useful for sizing a battery: a device drawing 250 mA for 8 hours consumes 2 Ah, or 7,200 C. Integrating current over time yields charge, which is what a coulomb counter in a battery fuel gauge does. Because the time unit is built in, converting a charge to ampere-hours changes seconds to hours and nothing else. If a document gives charge in coulombs and current in milliamperes, convert both to base units before combining them, so that the answer lands in the unit you expect.
Older charge units
Before SI, the electrostatic system used the statcoulomb, also called the franklin, defined so that two unit charges at 1 cm exert a force of one dyne on each other. One coulomb equals about 2.998 × 10⁹ statcoulombs, close to 3 × 10⁹ because of the link to the speed of light. The electromagnetic system used the abcoulomb, equal to 10 C. Chemists sometimes quote the faraday, the charge of one mole of electrons. Physics papers in the Gaussian system still use statcoulombs, so conversions appear when comparing older texts with SI. Equations for forces and fields also take a different form in Gaussian units, so converting only the number is not enough in those cases.
Conserved and quantized
Charge is conserved: it cannot be created or destroyed in an isolated system, only moved. It is also quantized, appearing in integer multiples of the elementary charge for free particles, a fact established by the oil drop experiments of Millikan early in the twentieth century. Quarks carry fractions of one third, but they are never observed alone. Because of quantization, the counts of electrons behind small charges are whole numbers, and a sensor reading in femtocoulombs corresponds to a countable number of charges. Conservation is the reason charge totals can be checked by summing currents into a node, one of the basic laws used in circuit analysis.
Notation and where charge is not what it seems
Q is the usual symbol for charge and C is the unit symbol, so a capacitor value 10 C would be a charge, while 10 F is a capacitance. The abbreviation mAh is common in marketing, with the proper form being mA·h. Do not read mAh as milliamps per hour, which would be a rate of change of current. Battery capacity depends on discharge rate and temperature, so a rated figure applies to stated test conditions. The BIPM SI Brochure defines the coulomb as ampere second, and NIST SP 811 lists the ampere-hour as 3,600 C. This page converts charge units only and does not size batteries or chargers.
Precision and checking
- Retain charge measurement precision.
- A repeating ampere-hour factor uses finite numerical precision.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Choose a unit definition
Coulombs (C)
Definition, reference values and linked conversions.
Millicoulombs (mC)
Definition, reference values and linked conversions.
Microcoulombs (µC)
Definition, reference values and linked conversions.
Nanocoulombs (nC)
Definition, reference values and linked conversions.
Ampere hours (Ah)
Definition, reference values and linked conversions.
Milliampere hours (mAh)
Definition, reference values and linked conversions.
Picocoulombs (pC)
Definition, reference values and linked conversions.
Kilocoulombs (kC)
Definition, reference values and linked conversions.
Femtocoulombs (fC)
Definition, reference values and linked conversions.
Use a working converter
- Electric charge converter
- Coulombs to Millicoulombs converter
- Millicoulombs to Coulombs converter
- Coulombs to Microcoulombs converter
- Microcoulombs to Coulombs converter
- Coulombs to Nanocoulombs converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.