Counting field lines through a loop
Magnetic flux measures how much of a magnetic field passes through a surface. A strong field through a large loop held square to the field has high flux, and the same loop turned edge-on has none. Flux is the quantity that changes in a generator, a transformer or a moving-coil pickup, which is why it appears throughout induction problems. This page computes it for a flat surface in a uniform field. Enter the field strength, the area and the angle, and the result is flux in webers. It is a short step in a longer problem about induced voltage.
The formula and the angle convention
The flux is Φ = B A cos θ, where θ is the angle between the field direction and the normal to the surface, the line perpendicular to it. OpenStax College Physics defines flux this way in its section on induced emf and magnetic flux. The angle is measured from the area normal, not from the plane of the surface. When the field is perpendicular to the surface, it is parallel to the normal, θ is 0 and the cosine is 1, so the flux is at its largest. When the field lies in the plane of the surface, θ is 90 degrees, the cosine is 0 and no flux passes through.
Flux at 60 degrees through 2 square meters
The page opens with a field of 0.5 T, an area of 2 m² and an angle of 60 degrees. The cosine of 60 degrees is 0.5, so the flux is 0.5 × 2 × 0.5 = 0.5 Wb. If the loop were turned so that the field passed straight through it, θ = 0 and the flux would be 1 Wb, twice as large. A tilt to 30 degrees gives 0.5 × 2 × 0.866025, about 0.866 Wb. The default values are large for everyday laboratory work, where fields are usually in the millitesla range and loop areas are a small fraction of a square meter.
Realistic loops and fields
A square coil of 10 cm by 10 cm has an area of 0.01 m². In a 0.2 T field aligned with its normal, the flux is 0.002 Wb, or 2 mWb. Tilted to 45 degrees, the flux becomes 0.002 × 0.707107, about 0.001414 Wb. The Earth's field of roughly 50 microtesla through a 0.5 m² loop with the field along the normal gives 2.5 × 10^-5 Wb, which is 25 microwebers. These are illustrative values chosen to show the scale. Real experiments use the measured field at the loop and a measured area. A circular loop of 5 cm radius has an area of π × 0.05², about 0.007854 m², so the same 0.2 T field aligned with its normal gives about 0.00157 Wb. Compute the area first, in square meters, and then use this page. Entering the area in square centimeters would make the flux 10,000 times too large, which is a common slip in lab reports.
Units: weber, tesla and volt-second
The weber is the SI unit of magnetic flux. One weber equals one tesla times one square meter, and it also equals one volt-second, which links the unit directly to induced voltage. The NIST guide to SI units lists the weber among the derived units with special names. In the older CGS system flux is measured in maxwells, and one weber equals 10^8 maxwells. Flux density, in teslas, describes how concentrated the field is, while flux is that density integrated over an area. Keep the two apart when reading datasheets for magnets and cores.
From flux to induced voltage
Faraday's law says the induced voltage in a coil of N turns equals N times the rate of change of flux. If a coil with 100 turns loses a flux of 0.002 Wb in 0.05 s, the average induced voltage magnitude is 100 × 0.002 / 0.05, which is 4 V. This page supplies the flux values before and after, and you take the difference. A rotating coil changes its angle continuously, so flux varies as the cosine of the rotation angle, and the induced voltage follows a sine wave. That is the principle of the alternating-current generator. Consider a loop of 0.01 m² rotating in a 0.2 T field. Its flux swings between +0.002 Wb when the plane is square to the field and -0.002 Wb half a turn later, so the total change over that half turn is 0.004 Wb. At 50 turns per second a half turn takes 0.01 s, and the average induced voltage over that half cycle is 0.4 V for a single turn. A coil with many turns multiplies that figure by the turn count, which is how practical generators reach useful voltages.
Common mistakes with the angle
The most frequent error is using the angle between the field and the surface itself instead of the normal. A field making a 30 degree angle with the plane of a loop makes a 60 degree angle with its normal, so the correct flux uses cos 60, not cos 30. Entering the wrong one swaps the answer between 0.5 and 0.866 times the maximum. Also check that the angle is entered in degrees. The formula converts to radians internally. Typing radians as degrees gives very small angles and a flux close to the maximum. For example, entering 1.047 for 60 degrees treats the angle as barely one degree, and the cosine stays near 1. A quick sanity check helps: as the angle grows from 0 toward 90 degrees the flux should shrink steadily from its maximum B times A toward zero. If a result is larger than B times A, an input is wrong, since the cosine cannot exceed 1. Reversing the field direction gives an angle past 90 degrees and a negative flux, which is allowed and simply marks flux passing through the surface in the opposite sense.
Uniform field and flat area assumed
The page assumes the field is uniform across a flat area. A non-uniform field needs an integral over the surface, and a curved surface needs the normal to be evaluated at every point. Several turns multiply the flux linkage by the number of turns, which you apply yourself. Materials that concentrate field, such as an iron core, change the field value and should be reflected in the B you enter. The result is a finite scalar educational estimate with no design or safety assessment attached. Eddy currents, leakage flux and the saturation of magnetic materials are also outside the model, so the page suits idealized loops in a stated field rather than finished transformer or motor designs.