Where milliwatts live

Milliwatts are the working unit of small electronics. A laser pointer, a Bluetooth earbud, a status LED and a Wi-Fi radio are all rated in them. Terawatts belong to national and global energy statistics. A reader who wants both on one scale, for a classroom table or a data dictionary, can use this page. It multiplies terawatts by 10^15 and returns milliwatts, so the default 10 TW becomes 10,000,000,000,000,000 mW, which is 1 × 10^16. The prefix distance is five steps of a factor of 1,000: giga, mega, kilo, the watt and then milli. Each step adds three zeros, and the exponents agree. The result is a convenient companion to the dBm table in the radio sections of a data sheet, where milliwatts are the reference. For a quick mental check, remember that 1 W is 1,000 mW and a kilowatt is a million.

The factor in steps

Count down the ladder: 1 TW is 1,000 GW, which is 10^6 MW, 10^9 kW, 10^12 W and 10^15 mW. The result for 0.5 TW is 5 × 10^14 mW, and for 0.0001 TW it is 10^11 mW. The SI Brochure defines tera and milli exactly, so the conversion is not an approximation. If your answer has eighteen zeros instead of fifteen, you used the microwatt factor, and if it has twelve, you used the plain watt factor. Reading the number back against the ladder takes seconds and catches most errors, particularly when a spreadsheet displays long values without separators. Entering the same value as 1e13 W in a script and multiplying by 1000 gives the same milliwatt figure for a cross-check.

Laser pointers, LEDs and Wi-Fi

Consumer laser pointers are limited by safety classes: class 2 lasers are limited to 1 mW and class 3R to 5 mW of visible output. A small indicator LED may take 20 mA at 2 V, which is 40 mW of electrical input. A Wi-Fi router in the 2.4 GHz band is limited in the European Union to 100 mW of effective radiated power, which is 20 dBm, and Bluetooth class 2 devices transmit up to 2.5 mW. These milliwatt values are familiar, and the converted terawatt figure of 10^15 mW shows the span from a pocket device to an energy system. The cited ratings should be checked against the device label. Regional rules differ, and the limit that applies to a router depends on the band and the country. A hobbyist who buys a laser pointer online should look for the class marking and the stated output, since an unmarked unit may exceed the limits for its class.

dBm as milliwatts in disguise

Radio gear quotes power in dBm, referenced to 1 mW. So 0 dBm is 1 mW, 20 dBm is 100 mW, and 30 dBm is 1 W. A terawatt is 150 dBm, and the default 10 TW is 160 dBm, because ten times the power adds 10 dB. The page works in linear milliwatts, and the decibel scale compresses the range into small numbers. To convert a milliwatt value to dBm, take ten times the base-10 logarithm of the power in milliwatts. For example, 100 mW gives 10 × log10(100) = 20 dBm. Transmit limits in regulations are often written in dBm, so this relation comes up often. Going the other way, 0 dBm is 1 mW, -10 dBm is 0.1 mW, and each 3 dB step roughly doubles or halves the power.

Headphones and audio

Headphone amplifiers state output in milliwatts per channel, for example 30 mW into 32 ohms. At that power the voltage across the headphone is the square root of 0.030 W × 32 Ω, about 0.98 V RMS. Efficient earphones reach comfortable listening levels with a few milliwatts, and large studio headphones need more. These figures are small beside a terawatt, but the same unit relationships apply. Converting both to milliwatts lets you compare orders of magnitude in an educational setting, while the headphone example shows how a milliwatt rating connects to voltage and impedance through P = V² divided by R. At 32 Ω, 1 mW corresponds to about 0.18 V RMS, which shows how little voltage a quiet passage needs.

Power on a spec sheet

Component data sheets list absolute maximum power in milliwatts for small resistors and diodes. A 0.25 W resistor is rated 250 mW, and a signal diode may be rated at 500 mW. Designers compare the dissipation in the circuit, V × I or I² × R, with that rating and leave a margin for temperature. A current of 5 mA through 1 kΩ dissipates 25 mW, which is a tenth of the rating of a quarter-watt part. The page does not run those checks. It restates a power in milliwatts, so you can set the data sheet and the calculation in one unit. For a part that must survive the worst case, use the rated maximum and not the typical figure on the front page.

Going from milliwatts to terawatts

Select milliwatts as the source and terawatts as the target to divide by 10^15. A value of 5 × 10^15 mW is 5 TW. A single 100 mW radio is 10^-13 TW, an unwieldy figure that illustrates why small powers are quoted in small units. If you must compare the two in text, state the ratio instead: 10 TW divided by 100 mW is 10^14, a hundred trillion radios. The ratio is a purely arithmetic statement and makes no claim about devices in use. The round trip returns the original number, since both conversions are exact. A small power like 3 mW stays readable in milliwatts, and moving it to watts gives 0.003 W.

Choosing digits

The default result has sixteen digits, and no measurement of a national power total is known to that precision. Round the converted value to the significant figures of the source before you quote it. For a figure such as 10 TW, one or two significant digits is the honest choice. If the number is a rating, such as 2.5 mW, keep the digits the label gives. Showing the original value beside the converted one lets readers verify the step. A rating such as 5 mW has one significant digit, and 5.000 mW would claim more than the label says. Rounding is for the reader, and the stored value can keep every digit.

Regulations and labels set the limits

The page only moves a decimal point. It does not check a laser class, a radio regulation or a component rating. Those limits come from the device label, the regulator and the data sheet.