Where tons and PS appear in the same file
Refrigeration capacity and engine power usually live in different catalogs, but they meet in procurement spreadsheets for plants that mix equipment from several regions. A cold store may use compressors from a European maker rated in kW or PS, evaporators from a US supplier rated in tons, and condensing units from Japan rated in kilocalories per hour. This page translates tons of refrigeration (TR) into PS so a single column can carry them all. The default of 10 TR converts to 47.81589148950514 PS. The menus also include watts, kilowatts, megawatts, BTU per hour, mechanical horsepower, the identical hp metric entry, and the small SI prefixes. PS is the German abbreviation of Pferdestärke, and it is the same unit as metric horsepower, so this page and its hp metric counterpart give the same number. The only difference is the name that you want to see in the result.
How the factor is built
A ton of refrigeration is defined as 12,000 BTU(IT) per hour. With the international table BTU of 1,055.05585262 J, that equals 3,516.8528421 W. A PS is 75 kgf·m/s, and with standard gravity of 9.80665 m/s² it equals exactly 735.49875 W. The ratio is 3,516.8528421 / 735.49875 = 4.78158914895. So one ton is a little less than 4.8 PS, and ten tons are 47.8 PS. Because both definitions are exact, the factor is exact to the digits shown. The page applies it by passing through the watt, which is how every pair in the menus is connected. Nothing in the calculation depends on temperature, refrigerant or the efficiency of the equipment, which also means that nothing in the result says how much power an engine or motor would need to deliver a ton of cooling.
The Japanese refrigeration ton
Not every ton is the same ton. In Japan, the refrigeration ton (JRT or RT) is defined as 3,320 kilocalories per hour, which comes to about 3.86 kW. That is roughly 9.8 percent larger than the US ton of 3.517 kW used here. A Japanese catalog listing a 10 RT unit therefore describes about 38.6 kW of cooling, or 52.5 PS-equivalent, while a US 10 ton unit is 35.2 kW or 47.8 PS. If you enter a Japanese tonnage into this page, the result will be about 10 percent low. To convert correctly, first turn the Japanese rating into kilowatts, using 3.86 kW per RT, and then enter the kilowatts. The same care applies to documents that state only "tons" with no standard. Look for BTU/h, kcal/h or kW alongside the tonnage to decide which ton is meant.
A worked example with a mid-size system
Consider a 25 TR packaged chiller for a small office building. Its cooling capacity in PS terms is 25 × 4.78158914895 = 119.5397 PS. In kilowatts that is 25 × 3.5168528 = 87.92 kW. A procurement table that sorts everything by PS would place it between a 100 PS pump drive and a 150 PS diesel generator, although the two kinds of rating are different in meaning. Next, a reverse case. A supplier quotes a refrigeration load as 84 PS-equivalent, and you need tons. Dividing 84 by 4.78158914895 gives 17.57 TR. For a smaller number, 7.5 TR becomes 35.86 PS. These values are illustrative and describe no particular product. They show how the unit change scales linearly, so doubling the tons doubles the PS figure exactly.
Transport refrigeration units
Refrigerated trucks and trailers use transport refrigeration units rated in BTU/h or kW of cooling at stated box and ambient temperatures, often powered by a small diesel engine whose rating is in horsepower or kW. A unit rated at 20,000 BTU/h is 1.667 TR, which corresponds to 7.97 PS of heat flow. The diesel engine that drives it is rated in a few horsepower to a few tens of horsepower, and the compressor input is a fraction of the cooling capacity. This is a good example of the caution that accompanies this page: the 7.97 PS is the thermal capacity expressed in a power unit, and a small engine rated at 7.97 PS would not necessarily deliver that cooling, since the cycle multiplies work into cooling by its coefficient of performance. Look at the rated capacity at the temperature you need, since capacity at a frozen setpoint is much lower than at a chilled one.
Ton-hours and district cooling
Cooling energy is often billed in ton-hours. One ton-hour is 12,000 BTU, or 12.66 MJ, which equals 3.517 kWh of heat removed. District cooling networks and some commercial buildings track consumption in ton-hours, and a plant running 100 TR for 8 hours has delivered 800 ton-hours, or 2,813 kWh of cooling. The matching quantity in the PS world is the PS-hour, which equals 0.7355 kWh. One ton-hour is therefore 4.78 PS-hours. The ton-hour is the amount, the ton is the rate, and this converter handles the rate only. When invoices mix the two, such as a capacity charge per ton and a use charge per ton-hour, make sure you convert the matching quantity. The conversion between ton and PS does not change if you multiply both sides by hours, which is a handy way to check a calculation.
Nominal tons and actual capacity
A unit labeled 10 TR is a nominal rating. Actual capacity at the site depends on the temperatures of the air or water entering the evaporator and condenser, on altitude and on the age and cleanliness of the equipment. A split air conditioner nominally rated at 1 ton may deliver more than 12,000 BTU/h in mild weather and less in a heat wave. Capacity tables published by manufacturers list the capacity in kW across a grid of conditions, and the nominal tonnage is a label for a size class. If you convert the nominal figure to PS, you get the nominal heat flow in PS. If you need the actual figure at a hot design day, use the table first and convert second. A project that sizes a plant on nominal tons and then discovers a 15 percent shortfall at design conditions has made the error before the unit conversion.
Choosing between kW and PS in a table
Because kilowatts are the SI unit and the legal unit for power in most of the world, a table that carries both refrigeration and drive power is cleaner in kW. Tons convert to kilowatts at 3.5168528 kW per TR, and PS converts at 0.73549875 kW per PS. The PS column is then a courtesy for readers who expect it. If you prefer to keep PS, mark the column with the unit and the definition, such as PS = 735.49875 W, so a reader in the United States does not read it as mechanical horsepower. The difference between PS and hp is 1.4 percent, small enough to ignore in an approximate comparison, but large enough to matter if the number is used for contracts. The converter makes the factor explicit and avoids hand arithmetic with the long constant.
Checking a result by hand
Two quick checks catch most mistakes. First, the result in PS must be about 4.78 times the number of tons. Ten tons should give a number near 48, and 100 tons near 478. A result of 4.78 or 4,780 points to a misplaced decimal. Second, go through kilowatts. Multiply tons by 3.517 to get kW and divide by 0.7355, which should return about the same PS. For 10 TR, 35.17 / 0.7355 = 47.82. If you do the check with 3.5 and 0.74, you get 47.3, within about 1 percent, which is enough to catch an error of the order of a decimal place or a swapped unit. For a final number, use the page itself, because the long factor is tedious and easy to mistype. The same check works in reverse for PS to tons: divide by 4.78.
What the number means and what it does not
The result is a heat flow written in a unit of mechanical power. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not estimate how much shaft power or electrical power a refrigeration machine will use. The relation between cooling and input power depends on the cycle, the refrigerant, the temperatures and the load, and is described by COP, EER or kW per ton in the manufacturer's data. Use the page to line up units across documents, and keep the labels with the figures, for example "47.8 PS-equivalent of cooling", so a reader does not mistake a cooling capacity for an engine rating. For selection and safety decisions, rely on the manufacturer data sheets and the applicable codes.
PS per ton of cooling versus PS per ton of input
A compressor input figure can also be written per ton of cooling, and it makes the gap between capacity and drive power concrete. A chiller using 0.7 kW per ton has a COP of 3.517 / 0.7 = 5.02. Its compressor draws 0.7 / 0.73549875 = 0.952 PS for every ton, against the 4.78 PS of heat flow that the ton represents. For the 25 TR example, the cooling is 119.5 PS-equivalent while the input is 17.5 kW, which is 23.8 PS. The ratio of the two is the COP. This is the correct way to relate a compressor motor in PS to a plant in tons: convert the motor rating to kW, divide the cooling in kW by it, and compare with the machine's published COP. If the answer is far from the data sheet, check the operating conditions, since COP falls as the condenser gets warmer.
Quoting one plant two ways
A buyer comparing a Japanese quote with a US quote for a nominal 30 ton plant has to watch the definition. A 30 US TR plant removes 30 × 3.5168528 = 105.5 kW, which is 143.4 PS-equivalent. A 30 RT Japanese plant, at about 3.86 kW per RT, removes 115.8 kW, or about 157.4 PS-equivalent. The gap of 9.8 percent is larger than the efficiency differences between competing machines. The quote should state the capacity in kW or kcal/h at defined temperatures. If it states only a tonnage and a country of origin, ask which ton is meant. This page assumes the US ton, which is the one defined by 12,000 BTU/h and used in ASHRAE and AHRI documents. A rating in kW avoids the question, and the PS column can then be derived from the kW at 0.73549875 kW per PS.