The charge scale of sensors and discharges

Charges of a few picocoulombs are what piezoelectric sensors generate, what a photomultiplier tube delivers per detected photon, and what a partial discharge in high-voltage insulation releases. Coulombs are what batteries, capacitors and lightning deal with. When a measurement in picocoulombs has to be combined with a quantity in coulombs, such as a total charge in a calculation of current over time, the exponent has to be handled with care. This page converts a charge from picocoulombs to coulombs and keeps even a tiny nonzero value readable. The coulomb is the SI unit of electric charge, equal to one ampere-second. The conversion changes the unit and leaves the charge unchanged. It does not assess whether a charge is safe, whether a discharge is acceptable, or how a device behaves.

The factor and the default result

The page formula is C = pC × 10^-12. With the default input of 10 pC the result is 1 × 10^-11 C, which in decimal form is 0.00000000001, with ten zeros after the point before the 1. A value of 250 pC converts to 2.5 × 10^-10 C, and a value of 1,000 pC, which is 1 nC, converts to 10^-9 C. In the reverse direction, 1 C is 10^12 pC, a trillion picocoulombs. The factor is exact, since the picocoulomb is defined through the SI prefix pico, and NIST Special Publication 811 lists the prefixes. The long run of zeros is a hazard when copying, so use the exponent form when you record the result. The converter may print it as 1e-11, which is the same number.

The elementary charge and counting electrons

Since the 2019 revision of the SI, the elementary charge is fixed at exactly 1.602176634 × 10^-19 coulomb. A charge of 10 pC therefore corresponds to 10^-11 divided by 1.602176634 × 10^-19, which is about 62.4 million elementary charges. One picocoulomb is about 6.24 million, and one coulomb is about 6.24 × 10^18. Counting charges in this way is natural for detectors that register individual particles. A photomultiplier with a gain of 10^6 turns a single photoelectron into about 10^6 electrons, a charge of 1.6 × 10^-13 C, which is 0.16 pC. With a gain of 10^7 the pulse is 1.6 pC. The numbers are typical orders of magnitude. The actual gain depends on the tube and the voltage, and the converter does not model any detector.

Piezoelectric sensors and charge amplifiers

Piezoelectric accelerometers and force sensors generate a charge proportional to the applied acceleration or force, and their sensitivity is given in picocoulombs per unit. A sensor with a sensitivity of 10 pC/g subjected to 5 g produces 50 pC, which is 5 × 10^-11 C. A charge amplifier converts that charge into a voltage, and the gain is set in millivolts per picocoulomb. With a 100 pF feedback capacitor, a charge of 50 pC gives 0.5 V, since the voltage is the charge divided by the capacitance. The converter handles the charge unit only. The sensitivity, the feedback capacitance and the cable all enter the design of a real system, and the sensor data sheet is the authority on the numbers. These values are illustrative and typical of the class of device.

Partial discharge measurement

Partial discharges are small electrical discharges in the insulation of cables, transformers and switchgear, and they are a sign of insulation degradation when they persist. The standard measure is the apparent charge, reported in picocoulombs, and the test method is described in IEC 60270. Acceptance levels for equipment are set by the relevant product standards and range from a few picocoulombs to hundreds of picocoulombs depending on the equipment type and voltage class, so the value for a given component must be taken from its standard or specification. A reading of 5 pC is 5 × 10^-12 C. A reading of 500 pC is 5 × 10^-10 C. The converter changes only the unit of such readings and cannot judge whether a result passes a test or not.

A second example: charge on a small capacitor

The charge on a capacitor is the capacitance times the voltage. A 100 pF capacitor charged to 10 V holds 100 × 10^-12 F × 10 V, which is 10^-9 C, or 1,000 pC. A capacitor of 4.7 pF at 3.3 V holds 15.51 pC, or 1.551 × 10^-11 C. If the 1,000 pC discharges in 1 microsecond, the average current is 10^-9 C divided by 10^-6 s, which is 1 mA. These numbers show how small charges can produce measurable currents when they move quickly. They are textbook values and do not describe any specific circuit. The conversion on this page takes the charge in picocoulombs and gives coulombs, which is the unit needed when the next step of the calculation uses amperes and seconds.

Ampere-hours and coulombs

Battery capacity is given in ampere-hours or milliampere-hours, and the connection to the coulomb is exact: one ampere-hour is 3,600 coulombs, because an ampere is a coulomb per second and an hour has 3,600 seconds. One milliampere-hour is 3.6 C, which is 3.6 × 10^12 pC. The converter includes ampere-hours and milliampere-hours in its list, so you can see how huge the charge in a battery is compared with the picocoulomb scale. A 1,000 mAh cell holds 3,600 C, or 3.6 × 10^15 pC. The charge of 10 pC is about 2.8 × 10^-12 of one milliampere-hour. The comparison is only a way to show the scale. The converter does not estimate battery life or capacity, and the rated capacity of a real battery depends on the discharge conditions.

Static electricity and the human body model

Electrostatic discharge testing uses a model of the human body as a capacitor of 100 pF discharged through a 1.5 kilohm resistor. A body charged to 2 kV holds 100 × 10^-12 F × 2,000 V, which is 2 × 10^-7 C, or 200,000 pC (200 nC). That is far above the picocoulomb values of sensors, which is why the picocoulomb is not a natural unit there, but a lower voltage or a smaller capacitance gives smaller charges. A 10 pF stray capacitance at 100 V holds 1,000 pC. The converter simply moves the prefix. The values here are examples of the arithmetic and not test levels. ESD protection requirements come from the standards that apply to the component or the product, such as the human body model and charged device model specifications.

Femtocoulombs and the scale below

Below the picocoulomb is the femtocoulomb, one thousandth of a picocoulomb, and the converter lists it. A charge of 10 pC is 10,000 fC. Femtocoulomb quantities appear in the charge injection of analog switches, in the input charge of low-noise amplifiers and in detectors that register a few thousand electrons. A charge of 1 fC is about 6,242 elementary charges. The sequence from coulomb to millicoulomb, microcoulomb, nanocoulomb, picocoulomb and femtocoulomb spans fifteen orders of magnitude, the same range as the sequence from ampere to femtoampere. The conversions on this page use only the picocoulomb to coulomb step, a factor of 10^12. The remaining steps are handled by changing the source or target unit in the list.

Common mistakes

Confusing pC with µC is the most damaging mistake, since it changes the answer by a factor of 10^6. The symbol C also stands for the coulomb only in the SI, and should not be confused with degrees Celsius, which is written °C. A second error is to treat picocoulombs as a measure of current. Charge divided by time is current, and picocoulombs per second are picoamperes. A third error is to confuse ampere-hours with amperes. A fourth is to drop the minus sign in an exponent, which would turn a tiny charge into a huge one. A fifth is to ignore the sign of the charge: coulombs can be negative, as for electrons, and the converter carries the sign through unchanged. Keep the unit with every number to avoid these slips.

Reading a charge from a current record

Charge is the time integral of current, so a record of current against time gives the charge by adding up the area under the curve. A pulse that peaks at 2 mA and lasts 1 µs with a triangular shape carries about half of the product of peak and duration, which is 1 nC, or 1,000 pC. A rectangular pulse of 5 µA for 2 µs carries 10 pC, the default value. In coulombs, those are 10^-9 C and 10^-11 C. Oscilloscopes with current probes and integrating electronics can report charge directly, and the display may show pC or nC depending on the range. When two instruments disagree by a factor of 1,000, check the prefix first. These pulse shapes are idealized examples used to show the arithmetic of integration.

Ionization chambers and radiation detectors

Radiation detectors such as ionization chambers collect the charge produced when radiation ionizes a gas. The charge collected in a measurement is often in the picocoulomb to nanocoulomb range, and the readout electrometer reports it in those units. Air requires about 33.97 eV of energy to create one ion pair, so a deposited energy of 1 J in air would, in principle, create about 1.8 × 10^17 ion pairs. In practice a measurement involves tiny energies. A deposit of 1 µJ yields about 1.8 × 10^11 ion pairs, a charge near 29 nC if all are collected, and a deposit of 1 pJ gives about 0.029 pC. The values are derived from the W value of air and are rounded. Calibration of a real chamber requires standards from a national laboratory, and the converter provides only the prefix change.

Scope and sources

The page converts a known electric charge between SI-prefixed units, ampere-hours and milliampere-hours. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it makes no statement about the safety of any discharge. The coulomb, the elementary charge and the prefixes come from the BIPM SI Brochure and NIST Special Publication 811. For testing and design, use the standards and data sheets that apply, and use the converter to move the prefix correctly.