A trillionth of a coulomb in sensor and insulation work

The picocoulomb, 10^-12 C, belongs to two quiet corners of electrical engineering. One is piezoelectric sensing, where accelerometers, force sensors and pressure transducers produce charge proportional to the load and report sensitivity in pC per unit of acceleration, force or pressure. The other is insulation testing, where partial discharge in cables, transformers and switchgear is measured as apparent charge in pC. Both fields rely on the picocoulomb because the signals are too small to list comfortably in coulombs. A student, test engineer or technician who has a charge in coulombs can use this page to restate it in picocoulombs, and the reverse direction handles values read from instruments.

The conversion factor

Pico is the SI prefix for 10^-12, defined by the BIPM and listed in NIST SP 811, so one coulomb equals 10^12 pC and the page uses pC = C × 10^12. The factor is exact because it only moves the decimal point twelve places. The inverse is C = pC / 10^12. A convenient way to remember it: one picocoulomb is one microampere flowing for one microsecond, since 10^-6 A times 10^-6 s equals 10^-12 C. The symbol is pC with a lowercase p. A capital P would be the peta prefix, a factor of 10^15, and a capital PC belongs to nothing in the SI, so mind the case when you copy a figure into a document. Pico also differs from the pica, a typographic unit, which has nothing to do with electricity but occasionally appears in the same documents when a table is typeset.

Reading the default 10 C result

The default of 10 C gives 10,000,000,000,000 pC, which is 10^13 pC. As with other tiny prefixes, the default exists to demonstrate the factor and not to represent a typical picocoulomb signal. Other entries show a more sensible range. An entry of 0.3 C gives 300,000,000,000 pC, and 2 µC entered in the From menu as microcoulombs gives 2,000,000 pC. Going in the opposite direction, 100 pC converts to 10^-10 C, or 0.0000000001 C. Picocoulombs also compare easily with neighbors: 2,000 pC equals 2 nC, and 10 pC equals 10,000 fC.

Piezoelectric sensors and the picocoulomb per newton

Quartz and other piezoelectric materials generate charge when stressed. Quartz has a charge coefficient of roughly 2.3 pC per newton along its most sensitive axis, a figure widely published in sensor literature, and a specific sensor model may differ. An accelerometer data sheet might specify a charge sensitivity such as 10 pC/g. Multiplying by the acceleration gives the charge in pC, and converting to coulombs gives 10^-11 C per g. The calculator converts the charge unit only. The sensor sensitivity, cable effects and amplifier gain have to be applied separately, and charge amplifier manufacturers publish the gain in mV/pC to make that step easy.

Partial discharge and apparent charge

International standard IEC 60270 covers partial discharge measurement and states results as apparent charge, usually in pC, with typical test limits for equipment set by the product standard. A reading of 5 pC on a high-voltage cable test is far below a coulomb by twelve orders of magnitude, which explains the unit. The coulomb value would be 5 × 10^-12 C. This page helps put such numbers in the units of another report, but it does not tell you whether a reading passes or fails. The acceptance level belongs to the standard and the equipment specification that your test follows. Calibration of a partial discharge detector is usually done by injecting a known charge pulse from a calibrator, and the pulse size is stated in pC, so the same unit appears both for the reference and the measurement. Converting between a calibrator setting in coulombs and a display in pC is exactly the job of this page.

Electron count and scale

One picocoulomb contains about 6.2415 × 10^6 elementary charges, from 10^-12 C divided by 1.602176634 × 10^-19 C. That is roughly six million electrons, which is why detector physicists treat pC-level pulses as signals above noise instead of as individual charges. In a photomultiplier tube, an output pulse of a few picocoulombs corresponds to a few tens of millions of electrons collected at the anode. These are illustrative magnitudes, and the actual gain of a particular tube depends on its voltage and design. The unit scale gives a sense of why an amplifier close to the sensor is usually needed. A charge amplifier converts the charge into a voltage with a feedback capacitor, so an input of 10 pC into a 1 nF feedback capacitor produces 10 mV, a relation sensor manuals use to state gain in mV/pC.

Neighbors of pC, and look-alike symbols

The neighbors are femto below and nano above. One nanocoulomb equals 1,000 pC and one picocoulomb equals 1,000 fC. A common slip is reading a chart axis labeled in pC as nC and being off by a thousand. Similar-looking symbols add confusion: pC is charge, pF is capacitance, and pA is current. A cable of 100 pF per meter does not store 100 pC per meter unless it has a stated voltage, and then Q = C × V gives the charge. Reading the unit symbol twice before plugging a figure into a formula is a cheap guard. A second guard is to count the zero groups: three zeros between prefixes, so coulomb to pico is four groups of three.

Trimming floating-point tails

Charge amplifiers and electrometers may be accurate to a few percent at best, so quote results to two or three significant figures. Floating-point output can show long tails such as 9,999.999999999998 fC for a conversion of 10 pC. Round them away before the number goes into a report. If you need to document the conversion, write the original value and unit next to the converted value. That makes later audits straightforward. In a spreadsheet, keep one column in coulombs and derive the picocoulomb column with a formula, so every figure traces back to the same source value.

Measurement noise at picocoulomb scale

This is a unit conversion. It does not evaluate sensor accuracy, cable noise, insulation condition or whether any reading meets a requirement. Measurement of charges this small is affected by cable movement, humidity, temperature and amplifier drift, and interpretation requires the relevant instrument manual or standard. Treat the converted number as an equivalent statement of the charge you provided and nothing more.