Resistance values that need a trillion

Teraohms belong to measurements of very good insulators: high-quality capacitor dielectrics, printed circuit board surfaces, glass and ceramic standoffs, cable insulation and the input of an electrometer. Capacitor makers quote insulation resistance or a time constant in megaohm-microfarads, and film types can reach into the teraohms. An instrument that logs raw ohms might store 2,000,000,000,000 as a long integer, and a report prefers 2 TΩ. This page divides by 10^12 and shows the result, switching to scientific notation for small answers. It serves test engineers and students who compare a measurement against a data sheet or a procedure written in teraohms.

Only the exponent changes between ohms and teraohms

Tera is 10^12 in the SI Brochure (BIPM) and in NIST SP 811, so the factor is exact. The formula is TΩ = Ω × 10^-12. Move the decimal point twelve places to the left: 5,000,000,000,000 Ω is 5 TΩ, and 300,000,000,000 Ω is 0.3 TΩ. Smaller readings come out as powers of ten, so 10 Ω is 1 × 10^-11 TΩ and 4,700,000,000 Ω is 0.0047 TΩ. The digits stay the same and only the exponent changes. A good habit is to work in gigaohms as a midpoint, since 1 TΩ is 1,000 GΩ, and 300,000,000,000 Ω is 300 GΩ. Both routes should agree, and if they do not, one of the zero counts is wrong. Writing the number with thin spaces or commas between groups of three digits, as in 5,000,000,000,000, makes that count easier to audit.

Why the default shows 1e-11

The page begins with 10 Ω and returns 1e-11 TΩ, which means 1 × 10^-11 or 0.00000000001 TΩ. A zero-count that long is easy to misread, so scientific notation is used. A 1,000 Ω resistor gives 1e-9 TΩ and a 1 MΩ resistor, entered as 1,000,000, gives 1e-6 TΩ. These are not values anyone would report in teraohms, and they serve to show how many powers of ten separate everyday parts from insulator-grade figures. When you enter a realistic value, such as 250,000,000,000 Ω, the answer is 0.25 TΩ. A spreadsheet accepts 1E-11 as typed, so you can copy results straight into a calculation without retyping.

Capacitor insulation and leakage

The leakage of a capacitor is often modeled as a resistor in parallel with it. A film capacitor with insulation resistance of 100 GΩ leaks little, and the figure is 0.1 TΩ. With a test voltage of 100 V, the leakage current is 100 ÷ 10^11 = 1 nA. A part at 1 TΩ would leak 100 pA at the same voltage, which is a challenge for an ordinary meter to see. Those currents explain why sample-and-hold circuits and long-interval timers use low-leakage film or C0G ceramic parts. The numbers here are illustrative, and the data sheet gives the guaranteed minimum for a given part, temperature and voltage. The page only converts the resistance unit.

Measuring at these levels is difficult

A handheld multimeter tops out at tens of megaohms. Readings in the gigaohm and teraohm range use an electrometer or a picoammeter with a source voltage, in a shielded fixture with guarding to keep surface leakage from adding in parallel. Humidity matters: a fingerprint or a damp board can reduce the apparent resistance of an insulator by orders of magnitude. Cables, connectors and the test fixture have their own leakage, which sets a floor on what you can read. Any value that comes out near the floor describes the fixture. Convert to teraohms only after you trust the reading, and note the test voltage, humidity and wait time next to the number.

Surface resistance in electrostatics

Packaging and flooring standards for electrostatic discharge control classify materials by surface resistance. Conductive materials sit below about 10^4 Ω, dissipative ones fall in the range from around 10^4 to 10^11 Ω, and insulative materials rise above that. Those categories vary between standards, so use the one that applies to your work. A reading of 3 × 10^10 Ω is 0.03 TΩ and sits within the dissipative range of a common classification, while 2 × 10^12 Ω is 2 TΩ and is insulative. Surface resistance is stated in ohms, since the standard defines a square geometry, so a teraohm value on this page shows scale and does not replace the test method.

Reading leakage current from a teraohm figure

Ohm's law links the resistance to the current that creeps through an insulator. At 10 V, a material measured at 1 TΩ passes 10 ÷ 10^12 = 10 pA. At 100 V and 0.1 TΩ, the current is 1 nA. Those currents are below what many bench meters can resolve, which is why teraohm testing uses an electrometer with a guarded fixture. When a data sheet lists a minimum insulation resistance, divide the test voltage by it to see the largest leakage allowed, then compare that with the noise of your instrument. If the allowed current is smaller than the instrument can read, the test cannot prove compliance. This page converts the resistance unit, and the current calculation is a separate step. Values here are illustrative.

From teraohms to ohms and gigaohms

Reversing the conversion produces long numbers. A 0.5 TΩ part is 500,000,000,000 Ω, and 2.5 TΩ is 2,500,000,000,000 Ω. In gigaohms the same values are 500 GΩ and 2,500 GΩ, and in megaohms they are 500,000 MΩ and 2,500,000 MΩ, which shows why the larger prefix is used. A test report that lists a surface resistivity or an insulation figure in teraohms also tends to list the test voltage and the electrode geometry beside it, because the number is meaningless without them. Counting digits in groups of three reduces mistakes: 500,000,000,000 has four groups after the leading 500. When you write a report, choose the prefix that gives a number between 1 and 1,000, so 500 GΩ is better than 0.5 TΩ and 2.5 TΩ is better than 2,500 GΩ. Software that stores integers should use 64 bits, because a 32-bit integer overflows near 4.3 billion and cannot hold even one gigaohm times five.

Noise floor and settling time at teraohm levels

Typing a teraohm-scale reading into the page changes its unit and nothing else. It does not tell you whether an insulator is good enough, which test voltage to use, how long to wait before reading, or what humidity correction applies. It also cannot check that a reading is above the noise and leakage floor of the instrument. Those points are covered by the manufacturer's manual and by standards for insulation, ESD control and capacitor testing. Treat the answer as a reliable restatement of the number you typed, and take interpretation from the document that governs your test.