Faint light and distant radio signals

A fiber technician measuring the light that comes back from a long cable, a student with a photodiode in a physics lab and a radio engineer who reads the received level of a distant transmitter all deal with powers in the range of nanowatts and picowatts. Instruments and reports switch between the two units depending on the level, so a table of readings may carry both. This page multiplies the nanowatt value by 1,000 and shows picowatts. A 2.5 nW signal is 2,500 pW. It helps when you want to compare a measured level with a sensitivity figure printed in the other unit, or when you merge data from two meters with different ranges. Calibration certificates for optical meters often list their reference levels in one unit while the working range is shown in another, so the same conversion appears in routine paperwork.

0.1 nW and 0.047 nW in picowatts

Nano is 10^-9 and pico is 10^-12, so a nanowatt contains 1,000 picowatts. The page uses pW = nW × 1,000. Pico and nano are SI prefixes with defined values, so 1,000 carries no uncertainty. By hand, shift the decimal point three places to the right. A reading of 0.1 nW becomes 100 pW and 0.047 nW becomes 47 pW. For the reverse, divide by 1,000, so 750 pW is 0.75 nW. Because the shift is small, most people do it mentally, and the page serves as a check on numbers copied from displays or reports. If a result is smaller than the input, the units are in the wrong order.

Ten nanowatts as ten thousand picowatts

The default input of 10 nW returns 10,000 pW. A 100 nW input gives 100,000 pW, and a 0.001 nW input gives 1 pW. The first number equals -50 dBm, the second -40 dBm, and the third -90 dBm. The way the dBm scale moves in steps of ten decibels per factor of ten in power makes it easy to check the output: add 10 dB for each factor of ten. The page shows only the unit conversion, but the dBm numbers can serve as a cross-check when a spreadsheet or an instrument displays levels in more than one form. If the dBm and the picowatt values disagree by a factor of ten, one of them has a slipped decimal.

Photodiode currents and optical power

A photodiode turns light into a current, and the ratio, called responsivity, is around 0.5 to 1 ampere per watt for common silicon and InGaAs devices in their working bands. At 0.8 A/W, 2.5 nW of light produces 2 nA, and 2,500 pW is the same light level. Measuring a current that small needs a low-leakage amplifier and a clean layout. If you are checking a design, convert the optical power into the unit the data sheet uses for the noise floor, usually picowatts, and compare them. The responsivity depends on wavelength, so use the curve from the data sheet for your light source. The page converts only the unit of power.

Wi-Fi and cellular levels in picowatts

Wireless receivers handle very small signals. A received level of -70 dBm is 100 pW, which is 0.1 nW, and -80 dBm is 10 pW. Phones and routers report these values in dBm, and most users never convert them. An engineer who wants to compare a received level with a thermal noise floor may prefer picowatts or femtowatts, since the noise power in a 20 MHz channel at room temperature is roughly 0.08 pW. That is -101 dBm. Converting between units helps check that a signal sits above noise by the required margin. A received level of 100 pW against a noise floor of 0.08 pW is a ratio of about 1,250, roughly 31 dB. The converter is a tool for the unit step and gives no information on coverage or throughput.

Picowatts back to nanowatts

For the reverse conversion, select picowatts as the From unit and nanowatts as the To unit. A reading of 4,200 pW is 4.2 nW, and a reading of 90 pW is 0.09 nW. The page divides by 1,000, which moves the decimal point three places to the left. Reports that show a series of readings should use one unit for the whole column, whichever makes the typical value fall between 1 and 1,000. If your values span from 50 pW to 5,000 pW, picowatts keep every number as a whole value above one, while nanowatts would produce a column of decimals. Whichever unit you choose, keep it fixed for the whole table so that readers can scan the numbers by eye.

Instrument noise and averaging

Meters that read picowatts have noise of their own, and readings jitter. Averaging 100 readings reduces random noise by a factor of ten, which turns a jitter of 20 pW into 2 pW, but it does not remove drift or offsets. Zero the instrument with the sensor covered or the input terminated before measuring, and repeat the zero check afterward. A reading of 120 pW with a jitter of 20 pW is not the same as one with a jitter of 2 pW, and a report should state the averaging time. The page can help you convert the average and the spread into the same unit, which is a start for a fair comparison.

The neighbors on the scale

Next to the nanowatt and picowatt are the microwatt at 1,000 nW and the femtowatt at one thousandth of a picowatt. A level of 0.003 µW is 3 nW, which is 3,000 pW. If you work with a data sheet that uses several of them, go one step at a time, since each step is a factor of 1,000. This reduces the chance of a slip by a factor of a million when you fix a spreadsheet. The converter offers a handful of power units, so you can reach watts or milliwatts if a source quotes in those. Write the unit in each column header and leave the original values in a separate column.

Detecting a 5 pW signal depends on bandwidth

Converting dBm to watts, estimating path loss and deciding whether a signal is detectable are tasks for other tools. Detection depends on bandwidth, noise, modulation and the instrument, so a reading of 5 pW may be clear in a narrow filter and lost in a wide one. For any decision that depends on a level, use the equipment manual, the standard for your application and a calibrated instrument. Note the resolution bandwidth next to each power figure, because the same source reads differently when the bandwidth changes. Quote both together, for example 5 pW in a 10 Hz bandwidth.