Meter ranges are labeled in millivolts
Bench multimeters and data loggers name their lowest range in millivolts, for example 100 mV full scale, while their resolution in the specification table is written in nanovolts. A reader who wants to know how many digits a meter really shows on that range has to move between the two units. This page divides the nanovolt value by one million and returns millivolts. A resolution of 100 nV becomes 0.0001 mV, so a 100 mV range with that resolution displays a million counts. Technicians who calibrate or compare instruments, and students who read data sheets in a measurement course, use the conversion to keep the figures consistent. Resolution and range pairings differ between models, so take the values from the specification table of the meter you actually use.
Dividing by one million
Nano is 10^-9 and milli is 10^-3, so one nanovolt is 10^-6 mV. The page applies mV = nV × 0.000001. Milli and nano are fixed by the SI, which makes the ratio of one million a defined number. By hand, the decimal point moves six places to the left. A value of 60,000 nV is 0.06 mV, and 2,500 nV is 0.0025 mV. Because six places are easy to miscount, a useful check is to go through microvolts: 1,000 nV make one microvolt and 1,000 µV make one millivolt, so 1,000 times 1,000 gives the million. When the result looks larger than the input, the From and To selections are probably reversed.
Why nanovolts rarely appear on a millivolt range
With the default input of 10 nV the page returns 0.00001 mV. Another example is a 100 nV step, which gives 0.0001 mV, and a 1,000,000 nV signal, which gives exactly 1 mV. The results show why nanovolts rarely appear on a millivolt range: the digits you care about sit in the fifth to seventh decimal place. If you have to quote such a value, switch to microvolts, where 100 nV is 0.1 µV and the number is easier to read. The converter shows the same quantity in whichever unit you pick, so you can test several and choose the one that keeps the number between 1 and 1,000.
Current shunts and tiny voltage drops
A current shunt turns current into a small voltage. A common 100 A shunt is built to drop 50 mV at full current, which is a resistance of 0.5 milliohm. At 1 mA through that shunt, the drop is 500 nV, or 0.0005 mV. Few meters can resolve that, so very small currents are measured with a different method. In the other direction, an electronics bench may use a precision shunt to read currents of many amperes, and the meter shows tens of millivolts. Converting between nV and mV lets you check whether the meter range is a good match for the current you expect before you connect anything.
ECG and sensor signals at the millivolt level
An electrocardiogram records signals of about one millivolt at the skin, which is 1,000,000 nV. A strain gauge bridge excited at a few volts delivers a few millivolts at full load, and a load cell data sheet quotes its sensitivity in millivolts per volt of excitation. Designers choose the amplifier so that the smallest change they care about, perhaps a few hundred nanovolts, is still larger than its noise. Placing the smallest step and the full signal in one unit, either millivolts or nanovolts, shows the dynamic range. A 2.5 mV signal with a resolution of 250 nV spans 10,000 steps. The converter reports only the unit change and leaves the filtering and the amplifier design to the designer.
From millivolts down to nanovolts
To find out how many nanovolts a given millivolt reading contains, choose millivolts as the From unit and nanovolts as the To unit. The page multiplies by one million, so 0.05 mV is 50,000 nV and 2.5 mV is 2,500,000 nV. This is useful when a spreadsheet stores readings as integers in the smallest unit, and you want to cross-check a few rows by hand. A quick test is to take the mV value, shift the decimal point six places to the right and compare the result with the stored number. If the two disagree by a factor of 1,000, the stored values are in microvolts rather than nanovolts. The same habit helps when you merge logs from two instruments, since one may export millivolts and the other nanovolts under similar column names.
Thermocouples read in millivolts
A type K thermocouple at 100 degrees Celsius, with its reference junction at 0 degrees, produces about 4.096 mV according to the NIST thermocouple tables, which is 4,096,000 nV. The sensitivity near that point is about 41 µV per degree, or 0.041 mV. A meter that resolves 100 nV, written as 0.0001 mV, can therefore distinguish steps of roughly 0.0024 degrees on paper. Real accuracy is limited by the reference junction, the wire and the connectors, and is far coarser than the resolution suggests. The table value is the point to start from, and the meter specification tells you the rest. Convert the voltage to millivolts here, then look up the temperature in the table or the instrument firmware.
Offsets, drift and the last digits
On a 100 mV range, a meter with 100 nV resolution shows a number like 12.3456 mV, yet its accuracy is specified as a percentage of reading plus a number of counts, so the last digits move with temperature and time. Offsets of hundreds of nanovolts are common in the circuit around the meter, and many meters have an auto-zero function that subtracts them. When you convert a reading that includes such an offset, the unit change will not remove it. Record the zero reading with the leads shorted, subtract it, and only then convert. Report the result with a number of digits that matches the stated accuracy.
A shunt reading still needs a division by resistance
A voltage restated in another unit has not been corrected for meter accuracy, offset or shunt scaling. For a shunt, divide the voltage by the shunt resistance to get amperes, which is a different calculation. For a biosignal, the filtering and the electrode setup matter more than the unit, and the equipment manual sets the rules. Use the page to keep the powers of ten in line, and then follow the data sheet for anything that depends on the instrument. Keep the conversion visible in your notes, for example 100 nV = 0.0001 mV, so a colleague can repeat it.