Noise figures meet signal levels

Data sheets for low-noise amplifiers and analog-to-digital converters tend to quote noise and step size in nanovolts, while the signals those parts are meant to measure are described in microvolts. An EEG electrode picks up activity in the range of tens of microvolts, and a thermocouple changes by tens of microvolts per degree. To judge whether a part is quiet enough, you put both numbers in one unit. This page divides the nanovolt value by 1,000 and returns microvolts, so a noise figure of 150 nV becomes 0.15 µV and can be read directly against a 50 µV signal. Students and technicians use it for homework, bench notes and part selection.

A factor of 1,000 and where it comes from

Nano is 10^-9 and micro is 10^-6, so one nanovolt is 10^-3 µV. The page uses µV = nV × 0.001, based on the prefix definitions in the BIPM SI Brochure and NIST SP 811, and the factor is exact. By hand, move the decimal point three places to the left: 4,500 nV is 4.5 µV, and 60 nV is 0.06 µV. The reverse step multiplies by 1,000, so 2.2 µV is 2,200 nV. Because only three places are involved, mental checks are practical. If the answer is larger than the input, the units are reversed. The micro symbol is the Greek letter mu, and plain text sometimes writes it as u, which means the same thing.

Ten nanovolts in microvolts

The default input is 10 nV, and the page shows 0.01 µV. A slightly larger figure, 150 nV, converts to 0.15 µV, and 4,500 nV converts to 4.5 µV. In each case the digits stay the same and only the position of the decimal point changes. A voltage as small as 0.01 µV is below the reach of ordinary multimeters, whose resolution on the lowest range is usually about a microvolt, so values like this appear on dedicated nanovoltmeters or in noise specifications rather than on a casual measurement. Seeing the result in microvolts makes the comparison with a meter range immediate.

Step size of a 24-bit converter

A 24-bit analog-to-digital converter with a 2.5 V reference divides its range into 2^24, or 16,777,216, steps. One step is 2.5 V divided by that number, about 149 nV, which is 0.149 µV. If your sensor produces a signal of 20 µV, that span covers about 134 steps, so the resolution looks adequate on paper. In a real design, converter noise is larger than one step, and the effective resolution is lower than the number of bits suggests. Check the data sheet for the effective number of bits or the RMS noise at your sample rate. The converter page handles the unit shift, and the design judgment stays with you and the manufacturer figures.

Biosignals from the skin

Surface electrodes pick up voltages that are tiny compared with household electronics. EEG signals are commonly described in the range of a few to a few hundred microvolts, and an input-referred noise of 1 µV is considered a sensible target for an amplifier that serves them. In nanovolts, a 50 µV EEG wave is 50,000 nV. Amplifier data sheets often list noise as a density in nV per square root of hertz. That is a different quantity from a plain voltage, since it depends on bandwidth, and the page converts only voltage values. Multiply the density by the square root of the bandwidth first, then enter the resulting nanovolt figure here.

Moving from microvolts back to nanovolts

Sometimes the starting point is the signal and you want to see it in the unit of the noise figure. A reading of 0.3 µV is 300 nV, and 12 µV is 12,000 nV. Set microvolts as the From unit and nanovolts as the To unit, and the page multiplies by 1,000. This is handy when you compare a sensor output against a list of op-amp noise values given in nanovolts, since a signal that sits below the amplifier noise cannot be recovered by averaging a few samples. Write down the bandwidth and the averaging time with the reading, because the usable resolution depends on both of them.

Load cells and the size of one count

A load cell rated at 2 mV per volt and excited with 5 V delivers 10 mV at full load, which is 10,000 µV. If the amplifier and converter together contribute 0.15 µV of RMS noise, which is 150 nV, the full span holds about 66,000 times the noise, so a weighing scale can resolve a small fraction of its capacity in principle. Peak-to-peak noise is several times the RMS figure, so the number of reliably stable digits is smaller, and drift with temperature matters as well. Seeing the span in microvolts and the noise in nanovolts on one scale makes this estimate quick. The load cell certificate and the amplifier data sheet give the values to use, and the figures here are illustrative.

Thermal voltages at connectors

Measurements at the microvolt level are sensitive to temperature gradients in the circuit. Where two different metals meet, such as a copper lead and a solder joint or a terminal, a small thermoelectric voltage can appear, often in the range of a few microvolts per degree of difference. That is thousands of nanovolts, enough to swamp a signal of a few hundred nanovolts. Technicians reduce the effect with short leads, matched materials, thermal shielding and by reversing the polarity of the source to cancel the offset. After measuring, you can convert the offset to the unit of your signal with this page and decide whether it matters.

Unit conversion, not measurement advice

A microvolt result inherits every limitation of the nanovolt reading. The page does not decide whether a reading is real signal or noise, apply a calibration, compensate for temperature or choose an amplifier. Whether a figure is RMS, peak or peak-to-peak also depends on the source, and the converter treats every number the same way. If the figure came from a data sheet, read the conditions printed beside it, such as bandwidth and source resistance, before comparing it with another part. If it came from your own meter, check the calibration date. Reporting the result with the same number of significant figures as the input avoids a false impression of precision. A noise figure of 150 nV with two significant figures should be quoted as 0.15 µV, not 0.150000 µV.