Datasheets that switch units mid-page
Precision amplifier datasheets are a good place to see why this conversion exists. The input offset voltage may be given in microvolts, the noise density in nV per root hertz, and a peak-to-peak noise figure in nanovolts or microvolts depending on the manufacturer. A designer who wants to add these contributions has to put them in one unit before doing any arithmetic. This page converts µV to nV by multiplying by 1,000 and back again by dividing by 1,000. Nanovoltmeters used for low-level measurements, such as thermoelectric voltages at low resistance, also show results in nV on their most sensitive ranges. The converter handles the units only. It does not judge noise performance or tell you which part to choose.
Factor and definitions
Micro is 10^-6 and nano is 10^-9 in the SI Brochure published by the BIPM. One microvolt is therefore 1,000 nanovolts, and the formula on this page is nV = µV × 1,000. The default entry of 10 µV gives 10,000 nV. The factor is an exact power of ten, so no rounding comes from the conversion itself. Because the page works in binary floating point, the default may display as 9999.999999999998, which is 10,000 nV with a small representation tail. Rounding your answer to the number of significant digits in the measurement avoids a false impression of precision.
Noise density times bandwidth
Noise in amplifiers is usually given as a density in nV per root hertz, and the voltage noise in a given bandwidth equals the density times the square root of the bandwidth. An amplifier rated at 5 nV per root hertz, read over a 10 kHz bandwidth, has 5 × 100 = 500 nV of rms noise. Dividing by 1,000 turns that into 0.5 µV. A data sheet that lists the same part at 0.5 µV rms and another that lists 500 nV describe one amount, and the converter confirms it. The illustrative 5 nV figure is chosen for easy arithmetic and does not describe a specific product. The page handles only the unit change, and the square-root rule is part of general noise analysis.
The last bit of a 24-bit converter
A 24-bit analog-to-digital converter with a 2.5 V reference has 16,777,216 steps, and one step is about 0.149012 µV. In nanovolts that is about 149.012 nV. Spec sheets for such converters often give the noise-free resolution in a smaller number of effective bits, so the step you can actually use may be many times this figure. Putting the step and the quoted noise in the same unit makes the gap clear. If the converter reports 1.5 µV peak-to-peak noise, that is 1,500 nV, about ten steps wide. That rule of thumb helps a designer decide whether more oversampling or a better reference is worth the effort.
Thermal voltages in low-level measurements
Joining two different metals creates a small thermoelectric voltage that depends on the temperature of the junction. When measuring a few microvolts across a low-resistance sample, a connector or a clip lead can add a reading of the same size as the signal. A user who sees a drift of 0.35 µV on a nanovoltmeter is looking at 350 nV, and which unit the meter prints depends on its range. Techniques such as reversing the current or using the instrument zero function are covered in manuals for these meters. This page supports that work by keeping the readings in one unit, so differences between a reading with the current on and with the current off can be written in nanovolts and compared.
Reading a small number correctly
Moving from microvolts to nanovolts makes a number larger, so a value like 0.0025 µV becomes 2.5 nV. Small decimal fractions of a microvolt are easier to compare in nanovolts because they become whole numbers. For example, 0.75 µV is 750 nV, and 12.5 µV is 12,500 nV. When writing a report, many engineers choose the unit that gives a mantissa between 1 and 999, so 750 nV is used rather than 0.75 µV, while 12,500 nV would normally be written 12.5 µV. A quick look at both forms on this page shows which is easier to read. Consistent units within a table matter more than the choice itself.
Instrument ranges and resolution
A meter with a 10 mV full-scale range and a seven-digit display resolves 1 nV at its last digit, and one with a 100 mV range resolves 10 nV. When you read a value such as 3,415 µV on a larger range, entering it here gives 3,415,000 nV, which looks like more precision than the instrument has. The number of significant digits depends on the display and the stated accuracy, not on the unit chosen. Compare the converted value against the meter specification, which lists accuracy as a percentage of reading plus a number of counts or a fixed offset in microvolts. Doing that in a single unit prevents a mismatch between the reading and its uncertainty.
Thermocouple and strain readings in nanovolts
Some thermocouple sensitivities are given in microvolts per degree Celsius, so a change of 1 °C produces a signal of a few tens of microvolts, and a data logger that resolves 100 nV can in principle see temperature steps a few hundredths of a degree wide. To work out the match, convert the logger resolution to microvolts: 100 nV is 0.1 µV. Dividing by the sensor sensitivity then gives the temperature step. Bridge sensors on structures behave the same way. A strain-gauge reading of 2.4 µV on a rosette is 2,400 nV. Whichever unit your instrument prints, convert both the signal and the noise to the same one before comparing them, and keep the unit symbol with every number in the notes.
What stays outside this page
The page only changes the unit of a voltage. It does not estimate measurement uncertainty, account for amplifier gain, bandwidth or source resistance, or check that any instrument is suitable for a task. Results are rounded for display and may show a floating-point tail on small values. The definitions of micro and nano come from the SI Brochure of the BIPM and from NIST SP 811, which are listed as the sources of this page. For safety-related work, ratings and limits come from the manufacturer and the applicable standards, and not from a unit conversion.