Two sizes of capacitor in one comparison

A nanofarad is the size of the decoupling capacitor next to a logic chip. A femtofarad is the size of the capacitance of a single wire, a transistor gate or a touch electrode in an integrated circuit. When a designer asks how the board-level part compares with the parasitic effect on the chip, the answer needs both on one scale, and the gap is large: a million to one. This page makes the move from nF to fF. The farad is the SI unit of capacitance, defined as one coulomb per volt, and the prefixes follow the standard powers of ten. The converter changes only the unit, so a capacitance of 10 nF stays the same physical capacitance when it is written as 10,000,000 fF. It does not calculate capacitance from geometry or check a component's tolerance, voltage rating or temperature behavior.

The factor and the default result

Nano is 10^-9 and femto is 10^-15, so the ratio between them is 10^6, which is 1,000,000. The formula on the page is fF = nF × 1,000,000. With the default of 10 nF the result is 10,000,000 fF, a number with eight digits. A small value such as 0.0047 nF becomes 4,700 fF, and 2.2 nF becomes 2,200,000 fF. The reverse conversion divides by one million, so 4,700 fF is 0.0047 nF. The factor is exact, because the SI prefixes are defined as powers of ten, and NIST Special Publication 811 lists them. The long strings of zeros are where mistakes creep in, so it helps to count the places in two groups of three: nano to pico is three places, and pico to femto is another three.

Picofarads in the middle

The intermediate prefix is the picofarad, and it is the unit in which small capacitors are most often sold. One nanofarad is 1,000 pF, and one picofarad is 1,000 fF. Breaking the conversion into those two steps is a good way to check the result. A 10 nF capacitor is 10,000 pF, which is 10,000,000 fF. Capacitor markings use picofarads with a three-digit code, in which the first two digits are the significant figures and the third is a power of ten. A code of 104 means 10 followed by four zeros, that is 100,000 pF, which is 100 nF, or 100,000,000 fF. A code of 472 means 4,700 pF, which is 4.7 nF. The converter lets you move through all the capacitance units, including farads, millifarads and microfarads, in a single step.

Femtofarads on a chip

Femtofarad values show up in the design of integrated circuits and sensors. The storage capacitor in a dynamic RAM cell is on the order of ten to a few tens of femtofarads, and the gate capacitance of a small transistor is in the same neighborhood or lower. A wire of a few hundred micrometers in a chip has a parasitic capacitance of tens of femtofarads. Capacitive touch and proximity sensors detect changes of a few femtofarads or even less, so the readout electronics are designed around that scale. These figures are broad orders of magnitude, since the exact values depend on the process and the design. The relevance for this converter is that a data sheet or a research paper may quote fF, while a board-level discussion uses nF, and the six orders of magnitude between them are easy to mishandle.

A second example with a parasitic capacitance

Consider an input pin with a parasitic capacitance of 4,700 fF, and a designer wondering whether it matters next to a 2.2 nF filter capacitor. Converting 2.2 nF gives 2,200,000 fF. The parasitic part is 4,700 divided by 2,200,000, or about 0.21 percent of the filter capacitor. In picofarads, the parasitic capacitance is 4.7 pF and the filter is 2,200 pF. The ratio is the same in any unit, which is why it is a good habit to compare ratios. The numbers are hypothetical. If the filter capacitor were 10 pF instead, the same 4.7 pF would be nearly half of it and would shift the filter noticeably. So the conversion tells you whether a small effect can be neglected next to a larger one, and by how much.

Charge, voltage and energy at these scales

The capacitance relates charge and voltage through Q = C × V. A 10 nF capacitor charged to 5 V holds 10 × 10^-9 F × 5 V, or 50 nanocoulombs. A 10 fF capacitor at 1 V holds 10 femtocoulombs, which is 10^-14 C, and that is about 62,000 elementary charges, since one elementary charge is 1.602176634 × 10^-19 C. The stored energy is half of C times V squared. For the 10 nF capacitor at 5 V that is 0.5 × 10 × 10^-9 × 25, or 125 nanojoules. The femtofarad scale therefore corresponds to a small number of electrons, which is why memory cells and sensors at that scale are sensitive to noise and leakage. The converter does none of this arithmetic, but the relations show why the unit scale matters.

Reading the output without losing zeros

A result like 10,000,000 is easy to miscopy. If you are entering it into a simulation netlist, consider writing it with the unit suffix the tool expects instead of a bare number. Many circuit simulators use f for femto, p for pico, n for nano and u for micro, so 10 nF may be written 10n and 10,000,000 fF may be written 10000000f. Be careful that in simulators the suffix m means milli and meg means mega, which is a case where capitalization does not follow the SI convention. When a result is long, switch to scientific notation: 1 × 10^7 fF. The converter may also print results as exponents when they are very large or very small, which follows the usual convention of the programming language that computes them.

Tolerances and what the unit change leaves out

Real capacitors have tolerances, a rated voltage, and a temperature behavior. Ceramic capacitors with certain dielectrics lose a large part of their nominal capacitance when a DC bias is applied, and the actual value in a circuit can be much lower than the number printed on the part. Converting 10 nF to 10,000,000 fF does not change any of that. The nominal value is a label, and the converter assumes you have a value that you trust. For on-chip capacitances, the numbers come from extraction tools and are given with their corner conditions. Treat the conversion as a unit change on a number whose accuracy depends on its source. If a result will feed a decision about performance, check the tolerance first.

Common mistakes

The most common mistake is a factor of 1,000 error between nF and pF, which turns into a factor of 1,000,000 for femtofarads. Remember the sequence: nano, pico, femto, each a factor of 1,000. Another mistake is to read the prefix as a different symbol. The symbol F for farad is capitalized and f for femto is lowercase, so fF is femtofarads while Ff means nothing in the SI. A third mistake is to confuse the farad with the coulomb, the unit of charge. Finally, do not read a capacitance in fF as a rating of voltage or current handling. The unit expresses the ability to store charge per volt, and nothing about limits.

Cables, traces and stray capacitance

Stray capacitance is easiest to feel in cables. A common coaxial cable of the RG-58 type has a capacitance of about 100 pF per meter, so a 2 m run adds around 200 pF, which is 0.2 nF or 200,000 fF. If that cable is connected to a sensor with an output stage that was designed for a few picofarads of load, the extra capacitance can slow the signal or cause instability. A short trace on a circuit board adds far less, on the order of a picofarad or less per centimeter, depending on the geometry. These values are typical orders of magnitude and not measurements of a specific cable or board, and the data sheet of the cable gives the actual figure. The converter helps put the cable, the trace and the on-chip effects into the same unit, so you can see which one dominates.

Sensing small changes in capacitance

Capacitive sensors turn a physical change into a change in capacitance. A touch screen, a proximity switch, a humidity sensor and a MEMS accelerometer each use a tiny change. Suppose a sensor has a baseline of 5 pF, which is 5,000 fF, and a touch adds 20 fF. The change is 0.4 percent of the baseline. Readout chips for such sensors resolve changes of a few femtofarads or less by measuring the charge needed to bring the capacitance to a reference voltage. The example numbers are illustrative. When a sensor data sheet gives sensitivity in fF per unit of the measured quantity, and the board-level filter is in nF, converting to one scale keeps the design discussion clear. A baseline of 0.005 nF and a change of 0.00002 nF are the same numbers as above, but harder to read.

Scope and sources

The page converts a known capacitance between SI-prefixed units and does not calculate capacitance from plate area, spacing or dielectric. It does not calculate installation limits, equipment ratings, protection, material response or compliance. The farad and the prefix definitions come from the BIPM SI Brochure and NIST Special Publication 811. For design work, rely on the manufacturer's data sheet for the tolerance, voltage coefficient and temperature range, and use this converter for the arithmetic of the scale change.