Two prefixes for small powers

Milliwatts and microwatts both describe small powers, and which one a data sheet uses depends on the field. Radio transmitters and lasers are often given in milliwatts. Ultra-low-power sensors, energy harvesters and sleeping microcontrollers are given in microwatts. A design that combines them needs one unit. This converter takes a value in milliwatts and returns microwatts. The default of 10 mW gives 10,000 µW. The page changes the unit of a power you already know. It does not estimate how much power a device uses, how long a battery lasts or whether a radiated power is allowed in a given country or for a given application. Datasheets in radio, optics and sensing use the two prefixes interchangeably, so the pair turns up constantly.

The factor of 1,000

The prefixes milli and micro mean 10⁻³ and 10⁻⁶. The ratio is 10⁻³ divided by 10⁻⁶, which is 1,000. The page formula reads µW = mW × 1000. The factor is exact, because the prefixes are exact powers of ten in the SI Brochure from the BIPM. The watt is the SI unit of power, one joule per second. The microwatt is the smaller unit, so the number gets larger by a factor of 1,000 when you convert into it. A simple rule is to move the decimal point three places to the right. The reverse conversion, from microwatts to milliwatts, divides by 1,000, which moves the decimal point three places to the left. It is one of the most common prefix steps in electronics. For quick mental work, remember that 1 mW is 1,000 µW, 0.1 mW is 100 µW and 0.001 mW is 1 µW.

The default of 10 mW

The default entry is 10 mW. Multiplying by 1,000 gives 10,000 µW. A check through watts: 10 mW is 0.01 W, and 0.01 W is 10,000 µW because a microwatt is 0.000001 W. If you land on 10 or on 10,000,000, you used the wrong direction or the wrong step. On the decibel scale referred to a milliwatt, 10 mW is 10 dBm, since dBm is ten times the base-10 logarithm of the power in milliwatts. In microwatts, the same power is 40 dBµW if you refer to one microwatt, because 10,000 is 10⁴ and ten times four is forty. The default is a power typical of small radio modules and low-power lasers, though specific devices differ.

The dBm scale as a bridge

In radio and optical communication, power is often expressed in dBm, decibels relative to one milliwatt. Zero dBm is 1 mW, which is 1,000 µW. A power of −30 dBm is 1 µW, and −20 dBm is 10 µW. Each 10 dB step is a factor of ten. A power of +10 dBm is 10 mW, and +20 dBm is 100 mW, or 100,000 µW. Converting between milliwatts and microwatts is therefore equivalent to adding or subtracting 30 dB when you express the number relative to a different reference. A received signal of −40 dBm, which is 0.1 µW or 100 nW, is quite typical for a nearby wireless link. The formula for converting dBm to milliwatts is 10 raised to the power of dBm divided by 10, so −20 dBm is 10⁻² mW, which is 0.01 mW or 10 µW.

Bluetooth power classes

Bluetooth defines transmitter power classes. Class 1 devices may transmit up to 100 mW, which is 20 dBm and 100,000 µW. Class 2 devices transmit up to 2.5 mW, which is 4 dBm and 2,500 µW. Class 3 devices transmit up to 1 mW, which is 0 dBm and 1,000 µW. The classes describe maximum output power, and many modern low-energy devices operate well below the maximum. Regulations on radio emissions differ by country and by band, and they may limit power below these maxima. Converting a class limit to microwatts allows comparison with the average power draw of low-energy sensors, which is usually much less. The figures describe maximum transmit power only, and they are not the same as the electrical power drawn from a battery, which is higher because of efficiency. Class names and limits are set by the Bluetooth specification and by national radio rules, so check the current documents for any compliance question.

Lasers and optical power

Optical power in milliwatts appears in laser pointers, fiber-optic transmitters and spectroscopy. Under the usual classification schemes, visible lasers below 1 mW fall into low classes, and those between 1 and 5 mW belong to a higher class that calls for more care, while stronger lasers need more precautions still. A 5 mW pointer emits 5,000 µW, and a 1 mW laser emits 1,000 µW. Fiber-optic receivers specify sensitivity as the minimum optical power needed, often in the range of microwatts or even less. A power meter reading 250 µW is 0.25 mW. The conversion helps to compare transmitter outputs, given in milliwatts, with receiver sensitivities, given in microwatts or dBm. Laser safety classification depends on the wavelength and exposure conditions, and this page does not provide it. Optical power meters often have ranges that start at nanowatts and end at hundreds of milliwatts, so readings are quoted in several prefixes in one session.

Electronics budgets

A small indicator LED driven at 20 mA with a forward voltage near 2 V consumes about 40 mW, which is 40,000 µW. A microcontroller in deep sleep drawing 1 µA from a 3 V supply consumes 3 µW, about thirteen thousand times less. Expressing both in microwatts, 40,000 and 3, makes the ratio clear without an exponent. Battery life estimates depend on such budgets, averaged over time. A device that draws 10 mW for 1 percent of the time and negligible power otherwise averages 100 µW, since 10 mW times 0.01 is 0.1 mW. The converter helps with the unit step in this kind of budget. It does not estimate duty cycles or model the circuits. The numbers are illustrative of typical orders of magnitude. Battery life then follows from capacity divided by average current, which is why microwatt-level averages can run a sensor for a long time on a coin cell.

Worked examples

Convert 2.5 mW: multiply by 1,000 to get 2,500 µW, the Bluetooth Class 2 maximum. Convert 0.25 mW: the result is 250 µW. Convert 100 mW: the result is 100,000 µW, the Class 1 maximum. For the reverse direction, 1.8 µW is 0.0018 mW, found by swapping the units and entering 1.8. A round trip should return the original value. Another check is in dBm: 2.5 mW is about 3.98 dBm, since ten times the base-10 logarithm of 2.5 is 3.979. And 2,500 µW referred to 1 mW is the same ratio of 2.5. These examples are chosen to be easy to verify. When a value has many digits after the decimal point, convert first and then round to the precision of the source. Doubling the input doubles the output, so 5 mW is 5,000 µW, and 50 mW is 50,000 µW.

Average power and duty cycle

Many small devices do not draw constant power. A wireless sensor may transmit for a few milliseconds every minute and sleep the rest of the time. The average power is the weighted sum of the active and sleep power. If the device draws 30 mW for 20 ms every 60 seconds and 5 µW otherwise, the average is roughly 30 mW times 20/60,000 plus 5 µW, which is 10 µW plus 5 µW, or 15 µW. Putting the active power in milliwatts and the sleep power in microwatts into a single unit makes this sum easy to check. This is the kind of calculation where the conversion is routinely needed. The page performs only the unit step, and the duty cycle arithmetic is up to the user. Sleep power often dominates the average when transmissions are rare, which is why designers track microwatts even in systems whose radios use milliwatts.

Case and symbol hazards

The symbols differ by a single letter: mW is a milliwatt, MW is a megawatt, and µW is a microwatt. The difference between mW and MW is a factor of one billion. Plain-text files often replace µ with u, so uW is common. Some tools treat prefixes case-insensitively, and merge mW and MW into one. In data sheets, power can also be written in dBm or dBW, which are logarithmic and cannot be converted with a simple multiplication. A reading in dBm needs the formula 10 raised to the power of dBm over 10 to get milliwatts. Check that the value you enter is a linear power in milliwatts. Putting a dBm figure in the milliwatt box produces a result that is wrong by orders of magnitude. The same warning applies to dBµW and dBW, which use other references.

Limits of the page

The converter changes the unit of a power value. It does not calculate installation limits, equipment ratings, regulatory emission limits, laser safety classes or compliance. It does not say how much electrical power a device draws or how long a battery lasts. For definitions of the watt and the SI prefixes, see the BIPM SI Brochure and NIST Special Publication 811. Keep the original unit beside each converted value so that others can retrace the steps. The factor is exact, so a difference from another tool usually comes from a different unit selection.