Meters that change range

Optical power meters, fiber-optic test sets and radio power sensors often show a reading in microwatts on a sensitive range and in milliwatts on a higher one. A technician logging results may see 850 µW on one connector and 1.2 mW on the next, and a report needs a single unit. This page divides microwatts by 1,000 to give milliwatts and multiplies by 1,000 for the other direction. The ratio is fixed by the SI prefixes, so the result does not depend on the meter. The converter changes units only. It does not check a laser safety classification, a link budget or a radio regulation, which have to come from the equipment manual and the applicable rules.

The factor

In the SI Brochure from the BIPM, milli is 10^-3 and micro is 10^-6. A milliwatt therefore holds 1,000 microwatts, and the page formula is mW = µW × 0.001. The default of 10 µW gives 0.01 mW, and the page may show 0.009999999999999998 because of binary floating-point rounding. Reading it as 0.01 is correct. The factor is a pure power of ten, so the digits stay the same and only the decimal point moves. 250 µW is 0.25 mW, 850 µW is 0.85 mW, and 5,000 µW is 5 mW. Counting three places left is the shortcut.

Decibels relative to a milliwatt

Radio and fiber-optic levels are often quoted in dBm, which is decibels relative to 1 mW. A level of 0 dBm is 1 mW, or 1,000 µW. Minus 20 dBm is 0.01 mW, which is 10 µW and the default value on this page. A receiver sensitivity of minus 28 dBm is 10^(-2.8) mW, about 0.001585 mW or 1.585 µW. To convert from dBm to mW, raise 10 to the power of the dBm value divided by ten. The page takes microwatts, so work out the milliwatt figure by hand and enter the microwatt equivalent to verify a result or to compare it with a meter reading in µW.

Laser pointers and class limits

Laser products are classified by their accessible output power. For continuous visible lasers, Class 2 is limited to 1 mW, which is 1,000 µW, and Class 3R extends up to 5 mW, or 5,000 µW, under IEC 60825-1. A pointer whose label says 5 mW can be entered as 5,000 µW to compare with a power meter that reads in microwatts. If a measurement shows 850 µW, that is 0.85 mW, under the Class 2 limit, though a label and a classification come from the manufacturer and not from this page. Use the converter to put readings and labels on one scale, and rely on the standard and on the manufacturer for any safety decision.

Fiber links and received power

In a fiber link test, the transmitter might launch around 0.5 mW, and a receiver might see 25 µW after passing through connectors, splices and length. The ratio between 0.5 mW and 0.025 mW is 20, which is 13 dB of loss. A technician converting the receive power from microwatts to milliwatts can then compare with the transmit level directly. Entering 25 µW gives 0.025 mW. The loss budget, connector quality and wavelength all matter for judging a link, and the page only changes the unit of a power value. Specifications for the transceiver in use state the allowed range.

Bluetooth and sensor radios

Low-power radios list transmit power in dBm or milliwatts. A short-range module transmitting at 0 dBm uses a radio output of 1 mW, and a unit set to minus 20 dBm outputs 10 µW. Input power to the chip is far greater than the radiated output, since the amplifier is not very efficient, so datasheet figures for current draw in the transmit state tell a different story from the radiated power. Converting the radiated figure from µW to mW makes it easy to compare modules from different vendors that choose different units. The converter does not estimate range, battery life or regulatory compliance, which depend on the antenna and environment. Regional rules set limits on radiated power for unlicensed bands, usually in milliwatts or dBm, and the figure to compare is the one the rule defines, such as conducted or radiated power, so read the rule text before using a converted number.

Rounding and significant digits

A reading from an optical meter, such as 847.3 µW, has four significant digits, and the converted value is 0.8473 mW, with the same four digits. Do not add extra digits when moving between units. When a meter has an accuracy of a few percent, quote two or three digits in a report. If you are averaging several readings, convert the average and not each reading, which gives the same number with fewer chances to slip. Small differences such as 0.8473 against 0.85 are within normal meter uncertainty, so a comparison of two sources should include the stated uncertainty of the instrument. Optical meters also depend on the wavelength setting, and a meter set to the wrong wavelength reads a few percent off, an error that no unit conversion will remove. Record the wavelength setting along with the power in your test log.

Light sources and photodiode currents

Photodiodes convert optical power to current with a responsivity in amps per watt, which is listed on the datasheet for each wavelength. A reading of 850 µW entered here comes out as 0.85 mW, and that value can be multiplied by a responsivity listed in mA per mW, which is numerically the same as A/W, to give the photocurrent in milliamps. Keeping the optical power in mW makes the current come out in mA directly, which avoids counting zeros. Use the responsivity from your own part, since it varies with wavelength and between devices.

Boundaries of this page

The page converts between microwatts and milliwatts. It does not account for wavelength-dependent meter calibration, connector losses or beam geometry, and it makes no classification of any laser or radio device. Safety and regulatory questions are answered by the standards and by the manufacturer data. The prefix definitions come from the BIPM SI Brochure and NIST SP 811, listed as sources for this page. Displayed values are rounded, and a very small result can show a floating-point tail.