From a plug-in meter to a power bill
A plug-in energy meter often shows standby power in milliwatts or in small fractions of a watt, while an electricity bill is written in kilowatt-hours. To connect the two you need kilowatts, because a kilowatt-hour is one kilowatt sustained for one hour. This page converts the milliwatt reading from the meter into kilowatts, so that you can multiply by hours and by your tariff. The conversion is a division by one million, which is easy to get wrong when many zeros are involved. Having the page return the figure removes one source of error when you estimate what a charger, a router or a smart speaker adds to the bill over a month.
Two steps of 1,000 make a million
A watt is 1,000 milliwatts, and a kilowatt is 1,000 watts, so a kilowatt is 1,000 times 1,000, or 1,000,000 milliwatts. The formula is kW = mW × 0.000001. These prefixes are defined in the SI Brochure from the BIPM and in NIST SP 811, and the factor has no rounding. In practice you move the decimal point six places to the left. A reading of 2,500,000 mW becomes 2.5 kW, and a reading of 750 mW becomes 0.00075 kW. Because the answer for small devices has many leading zeros, scientific notation is easier to read: 7.5 × 10^-4 kW. If the page shows a number larger than your input, the From and To units are reversed.
A sleeping sensor and a phone charger in kW
The page starts with 10 mW and returns 0.00001 kW, which is 1 × 10^-5 kW. A reading that low corresponds to something like a sleeping sensor or an indicator light. A more familiar case is a charger that shows 500 mW with no phone attached. Entered as 500, the page gives 0.0005 kW. A router at idle may read 6,000 mW, which is 0.006 kW. Those small kilowatt values have little meaning on their own, which is why people multiply them by time. The kilowatt figure is the bridge between a meter display and a bill, and the default example is just a short way to see how the digits shift.
Standby power over a year
To estimate energy, multiply kilowatts by hours. A device that draws 500 mW is 0.0005 kW. Over the 8,760 hours of a non-leap year that is 4.38 kWh. A device at 1,200 mW, or 0.0012 kW, uses 10.512 kWh in the same time. At an electricity price of 15 cents per kWh, which is an illustrative price and not a quote, the first costs about 66 cents and the second about $1.58 a year. These numbers explain why a single small device barely matters while a home with dozens of them can add up to a noticeable amount. Check your own tariff, since prices differ by utility, season and time of use.
Going from kilowatts to milliwatts
The reverse conversion helps when you read an appliance label and want to compare it with a meter that shows milliwatts. A 1.8 kW hair dryer is 1,800,000 mW. A 3.6 kW electric range element is 3,600,000 mW, and a 0.75 kW microwave oven in standby is a very different figure from the same oven running. The page multiplies by one million, so the decimal point moves six places to the right. When you enter a kilowatt value with a decimal, double-check the position of the point, since an error of one place changes the result by a factor of ten. The page prints digits clearly so that you can read them across.
Reading appliance labels
Appliance labels list rated power in watts or kilowatts, and many also list the current and voltage. A kettle of 1.5 kW draws 1,500,000 mW while it heats, but the label shows only the maximum. Real consumption depends on how long it runs. Milliwatt readings from a meter show the instant value, which varies as devices cycle. Take a reading over several minutes to see the typical figure, and then convert. Standby values on an older appliance can be higher than on a newer one, so a meter reading is more reliable than a label from a manual. Write down the date and the load conditions next to the reading.
Small solar and battery systems
People who build small solar-powered projects, such as a garden light or a remote sensor, size their panel in watts and their battery in watt-hours. A load of 150 mW is 0.00015 kW, and over 24 hours it uses 3.6 Wh, which is 0.0036 kWh. A 5 W panel produces thousands of times more than that on a sunny day, so the load is easy to supply, although cloudy days and battery losses reduce the margin. Converting milliwatts to kilowatts lets you place the small load on the same scale as a household figure when you compare, for example, the energy a sensor uses in a year with a refrigerator. The converter handles the arithmetic and leaves the system design to you.
Common slips with kilo and milli
The symbols kW and mW look similar in small print, and a missing letter changes the value by a factor of one million. A label that says 1 kW is not the same as 1 mW. Another error is mixing power and energy: kilowatts measure a rate, and kilowatt-hours measure an amount. Writing a device as using 0.0005 kW per month is wrong; it draws 0.0005 kW while on, and the energy depends on the time. Use the symbol kW for power, kWh for energy and keep the capital K out of it, since K stands for kelvin. Following those conventions keeps notes and spreadsheets readable for the next person who uses them.
From power to a bill: runtime and tariff come next
The page changes the unit of a power value. It does not measure how long a device runs, check a meter for accuracy, apply a tariff or decide whether a load is safe on a circuit. Power factor and apparent power do not enter, so a reading in watts from a meter is treated as real power. For a bill estimate, multiply the result by hours and by your price per kWh, and use your own utility rates. For an electrical installation, rely on the ratings and the code that apply where you live, and have a qualified person check the work.