Heaters on one side, routers and lasers on the other
Household appliances and workshop machines are rated in kilowatts. Wi-Fi routers, laser pointers, headphone amplifiers and LED indicators are rated in milliwatts. When a reader wants to know how a 100 mW router compares with a 2.5 kW heater, the two numbers need the same unit before the comparison means anything. This page puts kilowatts into milliwatts in one step. The default of 10 kW gives 10,000,000 mW. Because the two units are six orders of magnitude apart, the results run to many digits, and the reverse direction is just as useful for turning a small milliwatt rating into a fraction of a kilowatt.
One million milliwatts in a kilowatt
A kilowatt is 1,000 watts and a milliwatt is 0.001 watt. The page therefore multiplies by 1,000 and then by another 1,000, giving mW = kW × 1,000,000. The prefixes kilo and milli are defined in the BIPM SI Brochure and tabulated in NIST SP 811, and the watt is a joule per second. The factor contains no rounding. A microwave oven rated at 0.8 kW is 800,000 mW, and a space heater at 2.5 kW is 2,500,000 mW. The unit symbol for milliwatt is a lowercase m followed by a capital W. Writing MW with a capital M changes the meaning to megawatt, a thousand million times larger.
Wi-Fi power and what 100 mW means
Transmit power limits for wireless equipment are often stated in milliwatts. In the European Union, 100 mW of equivalent isotropically radiated power is a common limit for the 2.4 GHz band. That equals 0.0001 kW, a tiny fraction of the 2.5 kW heater in the same room. Entering 100 mW as the source and kilowatts as the target gives the figure. The comparison shows why a router does not warm a room, though the electrical power the router consumes from the wall is much higher than its radio output, since most of the draw goes into its processors and power supply. Radiated power and consumed power are different quantities. Router vendors list the radio output in milliwatts or dBm and the adapter rating in watts, so read the first for range and the second for running costs.
Laser classes in milliwatts
Laser safety classes are defined with output limits in milliwatts. A Class 2 laser pointer is limited to 1 mW of visible output, and Class 3R devices go up to 5 mW, under the usual definitions in the international laser safety standard. A 5 mW pointer is 0.000005 kW on this page. A shop that sells a laser level lists the output in milliwatts and the battery in watt-hours, and a buyer who wants to compare the two needs consistent units. This page does not assess eye safety. Follow the product label and the safety standard for the class of any device, and keep a laser away from the eyes of people and animals. Laser levels used in home renovation, for example, are typically sold in the low milliwatt range, and the label gives the class and wavelength.
Decibels relative to a milliwatt
Radio engineers state power as dBm, decibels relative to 1 mW. A signal of 1 mW is 0 dBm, 100 mW is 20 dBm and 1 W is 30 dBm. Moving up to a kilowatt, 1 kW equals 1,000,000 mW, which is 60 dBm, and 10 kW is 70 dBm. A broadcast transmitter at 10 kW therefore corresponds to 10,000,000 mW, the default result of this page, or 70 dBm. The conversion from milliwatts to dBm is ten times the base-10 logarithm of the milliwatt value. The page gives the linear value, and a calculator with a log function completes the step to dBm.
Audio amplifiers and headphones
Headphone amplifier specifications list output in milliwatts per channel into a given impedance, for example 250 mW into 32 ohms. A home theater amplifier lists watts per channel, and a concert sound system may list kilowatts. A 250 mW headphone amp is 0.00025 kW, and a 1.2 kW stage amplifier is 1,200,000 mW. A gap that large explains why a headphone amp can sit on a desk and a stage amp needs a rack and cooling. The conversion supports the comparison. How loud either one sounds depends on speaker sensitivity, which the page does not consider. A pair of headphones with high sensitivity can sound loud on a few milliwatts, while a floor speaker with low sensitivity needs many watts for the same level, so power ratings alone rarely settle a purchase.
LED and indicator ratings
An indicator LED runs at tens of milliwatts, and a lighting LED at a watt or more. A bulb listed at 9 W is 0.009 kW, or 9,000 mW. A strip with a total load of 24,000 mW is 0.024 kW. When you plan a power supply for a mixed load, convert every entry to one unit and add. A kilowatt unit is awkward for these small values, and a milliwatt unit is awkward for large ones, so the tool lets you move between them. For the supply you also need voltage and current, because power alone does not tell you what the supply must provide. As an illustration, a load of 24,000 mW is 24 W, and on a 12 V supply it draws 2 A. A supply rated for 3 A would cover it with some margin, which the power figure alone could not show.
Checks, display and reversing
To confirm the result, move the decimal point six places to the right when going from kilowatts to milliwatts. For 2.5 kW that gives 2,500,000 mW. To reverse, move six places to the left or choose milliwatts as the source. As an example, 5 mW is 0.000005 kW. The page shows at most 12 significant digits, so very long numbers keep their precision. A common error is to move only three places, which converts to watts instead. In a worked case, a 1.2 kW stage amplifier shown in the same table as a 250 mW headphone amp becomes 1,200,000 mW against 250 mW, a ratio of 4,800, which is easy to confirm by division. Look at the unit label on the result whenever the number looks too small or too large, and compare against anchors such as 1 kW being a million milliwatts.
Radiated, optical and electrical milliwatts differ
This page changes the unit of a power value. It says nothing about the efficiency of a device, the difference between input and output power, or safety limits for radiation exposure. A figure in milliwatts may describe radiated power, optical output, electrical consumption or an average over time, and the label of the source decides which. Regulatory limits for radio and lasers are set by national authorities and standards, and they may be expressed in different terms such as equivalent isotropically radiated power. Use the page for arithmetic and consult the applicable rule for compliance questions.