Picovolts in measurement and simulation

Picovolts appear in specialist places: the resolution tables of precision voltmeters, the output of circuit simulators that report tiny node voltages, the noise of a resistor in a narrow bandwidth, and the sensitivity of superconducting detectors. A student writing a lab report, an engineer reading a simulator log and a metrologist checking an instrument specification may all have a value in millivolts to compare with a figure in picovolts. This page multiplies the millivolt value by one billion and returns picovolts. The figures show how far an everyday signal is from the smallest voltages that instruments can resolve, a gap of nine orders of magnitude.

Nine decades between the units

Milli is 10^-3 and pico is 10^-12, so a millivolt holds 10^9 picovolts. The BIPM SI Brochure lists the volt as one joule per coulomb and defines these prefixes, so the conversion has no uncertainty. A useful check is to go through nanovolts: multiply by one million to get nanovolts, then by 1,000 for picovolts. For 0.0005 mV that gives 0.5 nV and 500 pV. The page does the single multiplication and agrees with this route. Digit counting also helps. A one- or two-digit input in millivolts should produce a result with ten or eleven digits, and a shorter answer means that a unit field was chosen incorrectly.

Ten millivolts in picovolts

The default 10 mV gives 10,000,000,000 pV, which is 1 × 10^10 pV. A much smaller input of 0.0000005 mV gives 500 pV, and 0.000001 mV is 1,000 pV, or 1 nV. In the reverse direction 250 pV equals 0.00000025 mV. These rows show where the picovolt unit becomes comfortable: below about a nanovolt. For anything larger, nanovolts or microvolts give fewer digits. When copying a ten-digit integer, write it in exponent form and keep the millivolt input in a neighboring cell, because a long digit string is the easiest place for a typing slip to hide. A reading of 0.0002 mV, which is 200,000 pV or 200 nV, shows the point: the same voltage appears as three different strings of digits depending on the prefix, and only one of them is comfortable to read.

Resistor noise in a narrow bandwidth

Thermal noise of a resistor has an RMS voltage of the square root of 4kTRB, where k is the Boltzmann constant, T the absolute temperature, R the resistance and B the bandwidth. For a 1 kΩ resistor at 300 K, the density is about 4.07 nV per root hertz. In a bandwidth of 0.01 Hz the voltage is about 0.407 nV, which is 407 pV, or 0.000000407 mV. The numbers are an illustration at an assumed temperature, and real circuits add other noise sources. They show that a picovolt-level figure arises naturally from physics when the bandwidth is small, which is the case in very slow measurements such as long integrations of a sensor drift. Doubling the resistance raises the voltage by the square root of two, and quadrupling the bandwidth doubles it, so a quick scaling check is possible without rerunning the calculation. At 100 Hz bandwidth the same resistor would give about 40.7 nV, which is 40,700 pV.

Instrument resolution tables

High-end digital voltmeters and nanovoltmeters list resolution for each range, and the smallest ranges may resolve a nanovolt or a fraction of one. A specification that gives a resolution of 0.1 nV equals 100 pV, which is 0.0000001 mV. Comparing that with a reading of 10 mV shows a dynamic range of 10^8, eight decades, which is why the number of digits displayed matters. Resolution is not accuracy: a meter may display 100 pV steps while its accuracy is several nanovolts, because of offsets, thermal voltages and noise. Read the accuracy section of the specification, not just the digit count, before relying on the smallest digits. A meter with 0.1 nV resolution and an accuracy of 5 nV on its lowest range would show values to 100 pV steps, but only the nanovolt-level digits carry reliable information, and a reading of 12,345 pV should be quoted as roughly 12 nV.

Converting picovolts back to millivolts

To convert the other way, set picovolts as the source and millivolts as the target. A value of 250 pV equals 0.00000025 mV and 407 pV equals 0.000000407 mV. The page divides by 10^9. The results have many leading zeros, so exponent notation, such as 4.07 × 10^-7 mV, is safer for software or a report. If a spreadsheet displays such a result as zero, widen the number format or use scientific format. An intermediate step through nanovolts, where 407 pV is 0.407 nV, is often easier to interpret by eye and gives you a figure you can compare with typical amplifier noise specifications.

Why picovolt claims need care

A claim of picovolt sensitivity needs context. Thermal voltages at connections, electromagnetic pickup, cable movement and the instrument's own noise can each exceed a picovolt by orders of magnitude. Measurements at this level use shielding, low-thermal connectors, cryogenic components or lock-in techniques that narrow the bandwidth. A quoted resolution of one picovolt without the bandwidth and measurement time is not enough to know what it means. When a document gives a picovolt figure, look for its conditions. The conversion on this page changes the unit, and the interpretation depends on the method that produced the number. Ask also whether the figure is a single reading, an average of many, or a statistical estimate of a noise floor, since each of these supports different conclusions about the smallest voltage that can be trusted.

Keeping one significant digit in 500,000 pV

The result keeps the significant digits of the input, since the factor is exact. A figure of 0.0005 mV has one significant digit and gives 500,000 pV with one significant digit, which is better written as 5 × 10^5 pV. The page does not estimate noise, convert a density into a voltage, calibrate an instrument or judge whether a measurement is feasible. Use it for consistent numbers, and rely on instrument documentation and metrology guidance for the rest. When you report a picovolt figure, include the bandwidth, the temperature and the averaging time next to it, so another person can judge what the number means and repeat the measurement under the same conditions.