Fifteen orders of magnitude in one table

A set of resistance specifications for a measurement instrument can hold a shunt of a few milliohms and an input resistance of hundreds of teraohms. The spread is fifteen orders of magnitude, which is wider than almost any other quantity a technician meets in a single document. This page converts a milliohm value into teraohms so that both ends can be written in one unit and compared by exponent. A student building a table of resistances from copper wire to glass can use it to place each material, and a test engineer can use it to check that a column of values has no entry that is off by a factor of a thousand. It converts the unit only and does not judge either value.

Where the factor of 10^15 comes from

Milli is 10^-3 and tera is 10^12, so one milliohm equals 10^-15 teraohm, and one teraohm contains 10^15 milliohms. The prefixes are defined in the BIPM SI Brochure and tabulated in NIST SP 811, so the factor is exact. A two-step check divides by 1,000 to reach ohms and by 10^12 to reach teraohms. The default of 10 mΩ gives 1 × 10^-14 TΩ. An input of 1,000 mΩ, which is 1 Ω, gives 1 × 10^-12 TΩ, and 5 mΩ gives 5 × 10^-15 TΩ. Results of this size are always shown in exponent form, because a decimal with fourteen zeros cannot be read reliably.

Teraohms in insulation and electrometer work

Resistances in the teraohm range appear in the insulation of high-quality capacitors and cables, in the surface resistance of plastics and in the input stage of electrometers, which are built to measure currents of picoamperes and below. At 1,000 V across 1 TΩ the current is I = V / R = 1,000 / 10^12 = 1 nA. A 5 mΩ joint in series with such a path changes the total by a part in 10^14, which no instrument can detect. The page makes that comparison concrete. The more practical concern at this end is leakage across surfaces and connectors, so measurements use guarded fixtures, dry air and clean, short, shielded cables to keep the reading near the true value.

Reading the default of 10 mΩ

The default result, 1 × 10^-14 TΩ, equals 0.00000000000001 TΩ. For a feel of the size, compare it with a gigaohm, which is a thousandth of a teraohm. In gigaohms the same 10 mΩ would read 1 × 10^-11. A larger milliohm value, such as 50,000 mΩ, which is 50 Ω, gives 5 × 10^-11 TΩ. Writing each result as a coefficient times a power of ten makes the order of magnitude visible, and a quick look at the exponent will catch a typing error. If the exponent is -14 for a 10 mΩ input, the page is behaving as expected. A practical habit is to write the exponent difference between two readings as well. A 5 mΩ joint and a 2 TΩ insulation figure differ by 5 × 10^-15 divided by 2, which is about 2.5 × 10^-15 of the larger value, a ratio no instrument can resolve. Seeing that number makes it obvious that the joint plays no role in the insulation reading, and that the two tests answer different questions.

Converting teraohms to milliohms

Select teraohms as the source and milliohms as the target to multiply by 10^15. A value of 1 TΩ gives 1,000,000,000,000,000 mΩ, and 3 TΩ gives 3,000,000,000,000,000 mΩ. Numbers this long are better copied in exponent form, such as 3 × 10^15. This direction matters in a data system that stores all resistances in one unit, where a teraohm insulation figure must be recorded alongside a milliohm joint. Check that the field type can hold the number, since a 32-bit integer cannot store values above about 2.1 billion, and floating-point storage rounds digits beyond about fifteen significant figures.

Measuring very high resistance

A multimeter cannot read teraohms. Dedicated teraohmmeters and electrometers apply a stable voltage, often 100 V to 1,000 V, and measure a current of picoamperes or less. Leakage along the surface of the test fixture, absorption in the insulating material and the time allowed for the reading to settle all affect the result, and standards for insulation resistance specify the electrification time, commonly one minute. Humidity changes surface leakage by orders of magnitude, so records should note temperature and relative humidity. Because the reading depends so much on conditions, a value in teraohms is useful for comparison between samples measured the same way and weaker as an absolute number. When two labs compare samples, they should agree on the voltage, the time before reading and the fixture, otherwise a factor of two between them says little about the material.

Capacitors and insulation resistance ratings

Film capacitors list insulation resistance in megaohms or gigaohms, often as a product with capacitance, written in ohm-farads or megaohm-microfarads. A value such as 30,000 MΩ·µF means a 1 µF part has 30,000 MΩ, which is 30 GΩ or 0.03 TΩ, and a 10 µF part of the same type has a tenth of that. This is a case where converting to teraohms helps when comparing with other materials in a table. The page changes the unit only, so work out the product rule first and then convert the resistance of the specific capacitor. Datasheets state the test voltage and time, which must be matched when comparing parts from different makers.

Symbol and notation traps

The symbols mΩ, MΩ, GΩ and TΩ are easy to mix up in handwriting and in plain-text exports. A mistake between mΩ and TΩ would be a factor of 10^15, so check every converted value against the plausible range of the part. A shunt that appears to read teraohms, or an insulator that appears to read milliohms, indicates a lost prefix or a swapped column. Spell out the unit in headers, keep each column in one unit, and avoid sorting a mixed column, because a sort by number will place 0.01 ahead of 5,000,000 regardless of the unit attached to each value.

Test voltage and the teraohm reading

The page converts the unit of a resistance and nothing else. It does not estimate leakage current, correct for temperature or humidity, assess whether a material passes an insulation standard or convert between resistance and resistivity, which also involves geometry. Surface and volume resistivity are separate quantities with their own units, and they need the sample dimensions. Use the page to align numbers across a table and rely on the applicable test standard for the judgment of a result.