Where teraohms turn up
Teraohm readings belong to leakage and insulation work. An electrometer or picoammeter characterizes a sensor fixture, a guarded test cable or a film capacitor, and its result is quoted as a resistance of hundreds of gigaohms to several teraohms. Insulation testers with 5 kV ranges also report values into the teraohm region on clean, dry equipment. Meanwhile the conductor side of the same product is specified in microohms, for example the contact resistance of a connector pin. A datasheet that lists both needs a common unit to be compared. This page converts the microohm figure to teraohms, so a 750 µΩ pin appears as 7.5e-16 TΩ next to an insulation figure of 2 TΩ.
Eighteen places of difference
The factor is the largest in the micro family on this site. One teraohm is 1,000,000,000,000 Ω and one microohm is 0.000001 Ω, so TΩ = µΩ × 1e-18. A value of 100 µΩ converts to 1e-16 TΩ, and 2 TΩ converts back to 2e18 µΩ. The BIPM SI Brochure lists micro as 10⁻⁶ and tera as 10¹², so the ratio is exactly 10¹⁸. Nobody types eighteen zeros reliably, which is the reason for the page and for scientific notation. The default result may print as 9.999999999999999e-18, which is display noise for 1e-17. Report it with the digits you measured.
The 10 µΩ default on the teraohm scale
Entering 10 µΩ returns 1e-17 TΩ. A resistance of ten microohms is typical of a heavy copper joint, and at the other end a teraohm is roughly what a good insulating spacer offers across a short gap. The two are 10¹⁷ times apart. A ratio of that size is not a curiosity. It is what lets a coaxial cable carry a femtoamp signal on its center conductor without the signal leaking into the shield, because the dielectric between them resists a thousand times more than a gigaohm. Seeing the default as 1e-17 puts the conductor side of that cable in its true place at the bottom of the scale.
Leakage current from a teraohm reading
Ohm's law links a teraohm figure to the current an electrometer sees. Ten volts across 1 TΩ drives 10 pA, and 5 kV across the same resistance drives 5 nA. A fixture that reads 0.2 TΩ at 10 V therefore leaks 50 pA, enough to swamp a 1 pA signal. Because of such numbers, low-current labs list fixture resistance in teraohms and signal lines in microohms or milliohms, and want both in one table. Converting 300 µΩ of wiring to 3e-16 TΩ shows the line is irrelevant to the leakage budget, which is dominated by surfaces, connectors and humidity rather than by metal.
Humidity and surface contamination
Insulation readings in the teraohm range are sensitive to the surface. Fingerprints, flux residue and moisture can lower a fixture from teraohms to gigaohms, a thousand-fold drop. That is why electrometer users clean and bake fixtures, handle them with gloves and keep test boxes dry. A reading of 4 TΩ in the morning and 80 GΩ after a humid afternoon describes the same part in two states. Converting the contact resistance in microohms to teraohms does not change that story, it only shows that the conductor never limits the measurement. The limits live in the dielectric, the guard design and the room, and they show up in the larger number.
Conversions in the reverse direction
Swap the menus to turn teraohms into microohms. A 1 TΩ reading is 1e18 µΩ, a 2.5 TΩ reading is 2.5e18 µΩ, and a 50 GΩ reading is 5e16 µΩ. These are rarely written in microohms in practice, but the conversion is handy for validating a spreadsheet that stores every resistance in one base unit, such as a quality database that holds microohms for contacts and teraohms for insulators. If the base unit is the ohm, convert first to ohms with the related page and then to the unit you want. Always keep the source reading beside the converted value so that a reviewer can see what the instrument displayed. In a production test, the same logic applies to a batch of fixtures: log the teraohm reading, the test voltage, the dwell time and the room humidity, because a teraohm figure without those conditions cannot be repeated.
Notation for numbers with eighteen zeros
Use E notation in files and exponent notation in text. In a spreadsheet, 7.5E-16 is accepted directly, while 0.00000000000000075 invites a miscount. In a printed report, write 7.5 × 10⁻¹⁶ TΩ, with the unit attached. Avoid mixing prefixes in one column. A column with entries like 7.5e-16 TΩ and 2 TΩ is correct but hard to read at a glance, so consider adding a second column that shows the ratio of the two resistances. Also keep the number of significant digits equal to what the instrument resolved, which for a micro-ohmmeter might be three digits and for a teraohm meter often only two.
Instrument ranges at the two ends
No single meter spans microohms to teraohms. A four-wire micro-ohmmeter works from fractions of a microohm to a few ohms, a multimeter handles ohms to tens of megaohms, and an electrometer or insulation tester carries the upper end. Moving between them is a change of instrument, not of range switch. Accuracy specifications also differ, and teraohm readings are often accurate to several percent at best, because tiny currents are affected by cable movement and ambient charge. When you place both readings in one table, state each instrument and its range, and treat the converted numbers as a way to compare magnitudes rather than as readings from one device. Calibration certificates for high-resistance standards usually list the test voltage with the value, since many insulating materials change resistance with applied voltage, and a teraohm figure at 10 V need not hold at 1,000 V.
Leakage paths and guard corrections
The converter changes a resistance unit and does nothing else. It does not model leakage paths, apply guard or temperature corrections, or judge whether an insulator meets a specification. It does not convert resistivity, surface resistivity or conductance, which use different units. The factor is exact because it is a power of ten, and differences from a published figure come from rounding of the entered value. For other prefixes, use the sibling pages in the microohm family, and always keep the measured reading in your report.