Project sizes in two units

Power projects are announced in whatever unit makes the number short. A rooftop solar array is quoted in kilowatts, a wind farm or a solar field in megawatts, and a national or regional system in gigawatts. News reports, grid operators and regulators switch between them. A data center operator might describe a campus plan as 300 MW, while a utility planning document sums up the load growth in a region as 1.2 GW. To compare or add the two, both must use the same unit. The page converts a megawatt figure to gigawatts so that the sum or the comparison is done on numbers that mean the same thing.

Moving the decimal three places to gigawatts

The SI prefix giga is 10 to the ninth and mega is 10 to the sixth (BIPM SI Brochure, NIST SP 811), so one gigawatt equals 1,000 megawatts. The page formula is GW = MW × 0.001. Move the decimal point three places to the left. A wind farm of 450 MW is 0.45 GW, 1,300 MW is 1.3 GW and 2,200 MW is 2.2 GW. A value below 1 GW is easier to grasp in megawatts, which is why plant listings often keep MW until the figure passes 1,000. The conversion is exact, so rounding in the answer reflects only the digits you enter. The page opens with 10 MW and returns 0.01 GW, the size of a small solar park or a modest industrial plant. If you enter a value and the result is larger than the input, the menus are swapped, and a result of 10,000 for an input of 10 means the To menu was set to kilowatts.

Data center campuses

Data center developers describe projects by the electrical capacity they request from the grid, often in megawatts per building and in gigawatts for a campus. A campus of four buildings with 250 MW each totals 1,000 MW, or 1 GW. A smaller edge facility at 8 MW is 0.008 GW. These figures describe contracted or planned electrical capacity and are not the same as the average power the buildings draw. Utilization, cooling overhead and growth plans change the load over time. The converter helps put the numbers on one scale, and the interconnection agreement or the utility study remains the source for what will be built or supplied.

Wind and solar nameplate capacity

Wind and solar projects are listed by nameplate capacity. A solar farm described as 120 MW is 0.12 GW. A wind project of 780 MW is 0.78 GW. Solar capacity is often stated as alternating-current output or as direct-current panel capacity, and the two can differ by a noticeable margin, so check which one applies before adding projects together. Nameplate capacity also differs from the energy produced over a year, which depends on weather and the capacity factor. A 100 MW plant does not produce 100 MW all day. Converting units does not change those considerations, and neither does it estimate production.

Power and energy are different units

Megawatts and gigawatts measure power, a rate. Megawatt-hours and gigawatt-hours measure energy, an amount. A 1 GW plant running at full output for one hour supplies 1 GWh, which is 1,000 MWh. The same plant at half output for two hours also supplies 1 GWh. News stories sometimes mix the two, writing GW for annual generation or GWh for capacity. When a report mentions a plant, check whether the number has an h in the unit. The converter works on power only. If you need energy, multiply by time first and then use the megawatt-hour or gigawatt-hour units.

From capacity to yearly energy

A capacity in gigawatts becomes an energy figure once you multiply by hours. One year has 8,760 hours, so 1 GW running at full output all year would supply 8,760 GWh. Real plants rarely do that. The ratio of actual annual output to that ideal figure is the capacity factor. Using an illustrative capacity factor of 35 percent, a 1 GW wind portfolio would deliver about 3,066 GWh in a year, since 8,760 × 0.35 = 3,066. Replace the 35 percent with the factor reported for your plant or region. The converter helps with the first step, getting the capacity in the right unit, and the multiplication by hours and by the capacity factor is separate arithmetic.

Adding projects and rounding

To add several projects, convert each to gigawatts and sum, or sum in megawatts and convert once. The second route introduces fewer rounding steps. Suppose a region lists projects of 450 MW, 320 MW and 275 MW. The sum is 1,045 MW, or 1.045 GW. Converting each separately gives 0.45, 0.32 and 0.275 GW, which add to the same figure. When you present results, round to the precision of the least certain input, since planning figures are often rounded to the nearest 5 or 10 MW. Showing 1.045 GW suggests more precision than the data supports, and 1.0 GW is usually enough for a headline.

Reverse conversions

Set From to Gigawatts and To to Megawatts to go the other way. 0.5 GW is 500 MW and 2.4 GW is 2,400 MW. The page also handles watts, kilowatts, Btu per hour, horsepower, metric horsepower, tons of refrigeration, nanowatts, microwatts and milliwatts, so a cooling plant listed in tons of refrigeration can be compared with a power figure in the same session. Each conversion is a plain unit change, and none of them says anything about efficiency. A chiller listed in refrigeration tons removes heat, while an electric rating in megawatts describes input power, and the two figures are not interchangeable without a performance factor.

Nameplate, net and contracted capacity

The page changes a power figure from one unit to another. It does not judge whether a project is feasible, whether a grid can carry it or how much energy it will deliver. It does not account for losses, availability or the difference between gross and net output. Use the capacity figure published by the plant operator, the grid operator or the regulator, and say in your own notes whether it is nameplate, net or contracted capacity. The conversion factor is exact, so any difference between your result and a published figure comes from rounding or from a different definition of capacity.