Putting SI flux into cgs form

Older physics and astronomy texts use the centimeter-gram-second system, where power per area appears as ergs per square centimeter per second. Modern engineering reports use watts per square meter. This page converts between them, starting from kilowatts per square meter. The default 10 kW/m² gives 10,000,000 erg/(cm²·s), or 10^7. The formula is erg/(cm²·s) = kW/m² × 10^6. Two steps explain it. A kilowatt is 1,000 W, and each watt is 10^7 erg/s. A square meter is 10,000 cm², so spreading that power over more square centimeters divides by 10^4. The product is 1,000 × 10^7 ÷ 10^4 = 10^6. The conversion changes units only, and it does not distinguish what kind of flux the number describes.

The erg, the watt and the area factor

The erg is the cgs unit of energy, defined as one gram centimeter squared per second squared. It equals exactly 10^-7 J, so one joule is 10^7 erg and one watt is 10^7 erg/s. NIST SP 811 lists the erg in its table of non-SI units with this exact relationship. The area conversion comes from the meter being 100 centimeters, so a square meter is 100 × 100 = 10,000 square centimeters. Together, 1 W/m² = 10^7 erg/s per 10^4 cm², which equals 10^3 erg/(cm²·s). All three factors are exact, so there is no rounding in the page result. The unit symbol for the target is erg/(cm²·s), written sometimes as erg cm^-2 s^-1 in astronomy papers, and the same quantity appears under both notations.

The default example worked out

For 10 kW/m², multiply by 10^6 to get 10^7 erg/(cm²·s), which is 10,000,000. A check in two stages: 10 kW/m² is 10,000 W/m². Multiplying by 10^3 gives 10^7. A third route uses W/cm²: 10 kW/m² is 1 W/cm², because 10,000 W spread over 10,000 cm² is 1 W per cm². And 1 W/cm² is 10^7 erg/(cm²·s), since one watt is 10^7 erg/s. All three routes agree. A smaller input of 1 kW/m² gives 10^6 erg/(cm²·s), and 0.1 W/m², which is 0.0001 kW/m², gives 100 erg/(cm²·s). Those cases show how the result scales linearly with the input. The drop-down lists include W/cm² and mW/cm², so you can verify the same conversions in the other direction.

Sunlight in cgs units

The best-known flux in cgs units is the solar constant. The total solar irradiance at the top of Earth's atmosphere averages about 1,361 W/m², or 1.361 kW/m², according to modern satellite measurements. In cgs units that is 1.361 × 10^6 erg/(cm²·s), which is how many astrophysics texts quote it. On the ground, standard test conditions for photovoltaic modules use 1,000 W/m², the 1 kW/m² reference at air mass 1.5, which is 10^6 erg/(cm²·s) or 100 mW/cm². Multiplying the solar constant by the area of a sphere whose radius is the mean Earth-Sun distance gives the solar luminosity of about 3.83 × 10^26 W, or 3.83 × 10^33 erg/s. Those figures are widely published, and slightly different values appear depending on the measurement epoch and calibration.

Heat flux and irradiance share the unit

The page notes that the same dimensions can describe heat flux or irradiance. Heat flux is the rate of heat transfer per area, for example through a wall or into a surface. Irradiance is the radiant power incident on a surface per area. Both are measured in W/m² in SI. Their physical meaning differs, and a number alone does not say which it is. A heat flux of 1 kW/m² through an insulated wall is a very large value, while 1 kW/m² of irradiance is bright sunlight. The converter treats them identically. It also does not tell you how much of the incident flux is absorbed, reflected or transmitted. Always state what the flux represents when you write the result, because 10^7 erg/(cm²·s) could be a heat load or a radiation level.

Fire testing and engineering context

Fire engineers use radiant heat flux levels in kW/m² as exposure conditions. Cone calorimeter tests under ISO 5660 commonly use 25, 35 or 50 kW/m² to expose material samples. Radiant heat flux thresholds such as a few kW/m² are used in hazard analysis for people and structures near fires, with higher levels leading to ignition of common materials. These numbers come from test methods and risk assessments, and specific limits depend on the standard, the material and the exposure time. In cgs terms, 25 kW/m² is 2.5 × 10^7 erg/(cm²·s). This page does not assess fire risk, material response or compliance. It restates a value in another unit system, which can be useful when reading older papers that quote ergs.

Geophysical and low-flux examples

At the low end, the average heat flow out of Earth's interior is about 0.09 W/m², or 90 mW/m², which is 90 erg/(cm²·s). Geophysics papers often use the unit mW/m² for this reason. The same flux in kW/m² is 0.00009, which converts to 90 erg/(cm²·s), so the page shows the full range of the factor. Laboratory radiometers measure irradiance in mW/cm² and W/cm², and a 1 mW/cm² source delivers 10^4 erg/(cm²·s). Comparing the geothermal flux with sunlight shows that the sun delivers more than ten thousand times as much energy per area, which is one reason surface temperatures follow the sun and not the Earth's interior. These are rounded values, and local heat flow varies strongly with geology.

Mistakes in area and power factors

The frequent error is to use 10^4 only, forgetting that a kilowatt is 1,000 watts, or to use 10^7 only, forgetting the area change. A conversion of 1 kW/m² to 10^7 erg/(cm²·s) is off by a factor of ten because it ignores the area. Another trap is confusing W/m² with W/cm², which differ by 10^4. A value of 1 W/cm² is 10 kW/m², not 1 kW/m². Another is to forget that a flux is per area per time: ergs alone are an energy, and erg/s alone is a power. The unit in the output has both denominators. A last pitfall is rounding the erg-to-joule factor, since 10^-7 is exact. Keep all the factors as powers of ten and the conversion remains exact.

Reverse conversion and verification

Select ergs per square centimeter-second as the From unit and kilowatts per square meter as the To unit to run backward. The page divides by 10^6, so 5,000,000 erg/(cm²·s) returns 5 kW/m². A solid check is the sunlight standard: 100 mW/cm² should equal 1 kW/m² and 10^6 erg/(cm²·s). If the chain is consistent, converting 100 mW/cm² to kW/m² and then to erg/(cm²·s) gives 1 and 10^6. The drop-down units give you several routes to compare. In a technical paper that mixes cgs and SI, convert once, state the converted value with the original in parentheses, and keep the same significant figures as the source value.

What the page leaves out

The page will not derive a heat flux from a temperature difference and conductivity, model radiation from a surface, or turn irradiance into illuminance. The spectrum, angle of incidence and measurement area behind a flux are likewise invisible to it. The NIST and BIPM materials cited on the page are the references for the definitions, and the physical interpretation of the number is yours to supply.

Worked example: a sun lamp and a furnace wall

Suppose a lamp delivers 0.8 kW/m² to a surface, an illustrative value below full sunlight. In cgs units that is 0.8 × 10^6 = 800,000 erg/(cm²·s). A wall in a furnace might receive a much higher flux, say 120 kW/m² as an illustrative engineering case, which is 1.2 × 10^8 erg/(cm²·s). Dividing the two gives 150, so the wall receives 150 times the flux of the lamp. The ratio does not depend on the unit system, so it is a good check: the converted values must give the same ratio, 1.2 × 10^8 divided by 8 × 10^5, which is 150. If the ratio changes, one number was converted with a different factor. Writing the unit next to every value in a table makes such errors easy to spot and prevents mixing of cgs and SI columns.

Photon flux and the radiometric chain

In radiometry the flux of energy can be turned into a photon flux if the wavelength is known. At 550 nm each photon carries about 3.61 × 10^-19 J, or 3.61 × 10^-12 erg. A flux of 10^6 erg/(cm²·s), equal to 1 kW/m², then corresponds to 10^6 divided by 3.61 × 10^-12, which is 2.8 × 10^17 photons per square centimeter per second, if all of the power were at that wavelength. Real sunlight spans a wide spectrum, so the actual count is different. The calculation shows how the cgs unit slots into astrophysical and optical formulas that use ergs for photon energies. The page converts only the power flux. The photon number requires a spectrum or a stated wavelength, and the example is for illustration of the method.

Reading older literature

Papers from before the 1970s, and many astrophysics papers still, quote fluxes in erg cm^-2 s^-1 and luminosities in erg/s. A reader meeting a value like 1.4 × 10^6 erg cm^-2 s^-1 for solar irradiance can convert it by dividing by 10^6 to get 1.4 kW/m². The same applies to magnetic units, with gauss in place of tesla, and to energy densities in erg/cm³. When you translate from these papers, retain the original number and unit in a footnote, because rounding can accumulate when values are converted back and forth. Also check whether the paper gives a flux per unit area on the surface of a source or at a distance, since the inverse-square law links them. The conversion factor itself is exact, and any discrepancy between a paper and a modern value usually comes from updated measurements.