Watts per square meter (W/m²): heat flux unit guide

W/m² is the reference for heat flux.

Measurement basis

This quantity expresses heat-transfer power per area.

Definition conventions

Irradiance can share these unit dimensions and measures incident radiant power per area. Preserve the source quantity label.

Conversion method

Keep W/m² unchanged; use another heat-flux factor for the target.

Reference equivalent of W/m²

1 W/m² = approximately 1 W/m².

Recorded scale factors: 1 for W/m²; 1 for W/m².

Worked example

Known input: 10 W/m². Reference equivalent: 10 W/m². The return conversion gives approximately 10 W/m².

The example preserves power per area.

Common reference values

Input (W/m²)Reference equivalent (W/m²)
11
55
1010
2525
5050
100100

Compare one W/m² with other units

Target unitEquivalent of 1 W/m²Definition guide
Kilowatts per square meter (kW/m²)0.001Read definition
Watts per square centimeter (W/cm²)0.0001Read definition
Milliwatts per square centimeter (mW/cm²)0.1Read definition
Ergs per square centimeter second (erg/(cm²·s))1000Read definition

The SI unit for flux across a surface

Watts per square meter is the coherent SI unit of heat flux density and of irradiance. One W/m² is a power of 1 W passing through, or arriving on, 1 m² of surface. In base units it is kg·s⁻³. The symbol q or the Greek phi with a subscript q usually denotes heat flux density, while E is common for irradiance. Both share the unit, which is why context decides the meaning of a number: a value of 800 W/m² in a building simulation means heat crossing a surface, while the same 800 W/m² on a pyranometer describes sunlight arriving. Because the unit is built from two coherent SI units, no conversion constant appears in its definition.

Solar numbers and the one-sun standard

The total solar irradiance at the top of the atmosphere, averaged over a year at the mean Earth-Sun distance, is about 1,361 W/m². On a clear day with the Sun high in the sky, the surface receives something like 1,000 W/m² of global irradiance, and photovoltaic modules are rated under standard test conditions of 1,000 W/m², as defined in IEC 60904-3. Averaged over day and night across the globe, the incoming flux per square meter of Earth surface is a quarter of the intercepted value because a sphere has four times the area of its cross-section, which gives roughly 340 W/m². These figures are measured quantities whose exact values are refined with new instruments.

Heat flow through a wall in W/m²

In buildings, W/m² describes conduction through an envelope surface. A layer or wall with a thermal transmittance U of 0.3 W/(m²·K) and a temperature difference of 20 K between inside and outside conducts 0.3 × 20 = 6 W/m². Over a 50 m² wall the total is 300 W. If the wall is replaced by a single pane of glass with U about 5.8 W/(m²·K), the flux for the same difference becomes 116 W/m², and over 5 m² that is 580 W. Heat flux sensors glued to a surface measure q directly in W/m², which lets building scientists compare measured and calculated values without knowing the layer properties.

Metabolism, ground heat and other low fluxes

The metabolic rate of a resting seated person is defined as 1 met, equal to 58.2 W/m² of body surface in thermal comfort standards such as ASHRAE 55. For an adult with roughly 1.8 m² of skin that is around 105 W. Heat flowing out of the Earth through the crust averages about 0.09 W/m², some ten thousand times smaller than sunlight, though it matters over geological time and in geothermal exploration. A kitchen oven wall, a hot water radiator surface or a sun-warmed pavement have fluxes in the hundreds of W/m². These magnitudes help you check a number: a result of 1,000,000 W/m² in a building context points to a unit slip.

Prefix and area conversions

Scaling to kilowatts is a power of ten: 1 kW/m² = 1,000 W/m², so a 1,361 W/m² solar value is 1.361 kW/m². The centimeter-based units follow from 1 m² = 10,000 cm²: 1 W/m² = 0.0001 W/cm² = 0.1 mW/cm². The site converters named Watts per square meter to Kilowatts per square meter, to Watts per square centimeter, to Milliwatts per square centimeter and to Ergs per square centimeter second apply those factors, and each has a reverse direction. The erg version is 1 W/m² = 1,000 erg/(cm²·s). A flux of 2,500 W/m² is therefore 0.25 W/cm², 250 mW/cm² and 2,500,000 erg/(cm²·s). All of these are the same flux written differently.

Inch-pound heat flux and the exact definitions

American practice uses Btu/(h·ft²). With the International Table Btu, equal to 1,055.05585262 J, one hour as 3,600 s and one square foot as 0.09290304 m², 1 Btu/(h·ft²) is about 3.1546 W/m². Thus 1 kW/m² is about 317 Btu/(h·ft²). The site does not list a converter for this inch-pound unit, so the factor must come from a published table such as NIST SP 811. The foot is defined through the international yard, 0.3048 m exactly, and the square foot follows from squaring that value. Some older literature uses a thermochemical Btu, which differs slightly, and the choice should be stated.

Radiation and the T⁴ scale

Thermal radiation from a surface follows the Stefan-Boltzmann law, flux = emissivity × sigma × T⁴, with sigma = 5.670374 × 10⁻⁸ W/(m²·K⁴) and T in kelvin. A blackbody at 300 K emits about 459 W/m², and at 600 K about 7,348 W/m², sixteen times as much because doubling temperature raises the fourth power by 16. The net exchange between a surface and its surroundings is the difference of two such terms, so a warm wall at 300 K facing surroundings at 290 K exchanges far less than its emitted flux. These calculations require absolute temperatures, and a Celsius value entered in place of kelvin gives a wrong answer by a large margin.

Keep area normalization in the claim

A power in watts alone is not a flux. The area relationship is what makes W/m² a flux, and the area has to be stated: the exposed face of a panel, the inner surface of a pipe or a patch of skin. Converting units does not check whether the flux is the incident, absorbed or net value, nor whether the number refers to a peak or an average over time. A surface that receives 1,000 W/m² and absorbs 85 percent of it gains 850 W/m² as heat, before losses. Write the area basis and the direction of flow beside any flux you publish, and convert only a value whose meaning is clear.

A flat-plate collector from irradiance to energy

An illustrative solar-thermal calculation shows the unit at work. With irradiance of 900 W/m² on a 2 m² collector whose absorber takes up 90 percent of the incident flux, the absorbed power is 900 × 0.9 × 2 = 1,620 W. If thermal losses remove 25 percent of that, 1,215 W reaches the fluid, which is 1.215 kWh over one hour. Daily solar resource data are often given in kWh/m² per day, and 1 kWh/m² equals 3.6 MJ/m², the same factor that links kWh and MJ everywhere. A site that receives 5 kWh/m² per day therefore receives 18 MJ/m². Those are averages over time, while W/m² is an instantaneous rate, and the two must not be compared without the hours.

Precision and checking

  • Keep source flux precision.
  • Retain any stated conditions.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →