Measurement basis
Its recorded reference factor is 0.001 W/m².
Definition conventions
Irradiance can share these unit dimensions and measures incident radiant power per area. Preserve the source quantity label.
Conversion method
Multiply by 0.001 for the reference heat flux.
Reference equivalent of erg/(cm²·s)
1 erg/(cm²·s) = approximately 0.001 W/m².
Recorded scale factors: 0.001 for erg/(cm²·s); 1 for W/m².
Worked example
Known input: 10 erg/(cm²·s). Reference equivalent: 0.01 W/m². The return conversion gives approximately 10 erg/(cm²·s).
The calculation preserves the energy-per-time power relationship.
Common reference values
| Input (erg/(cm²·s)) | Reference equivalent (W/m²) |
|---|---|
| 1 | 0.001 |
| 5 | 0.005 |
| 10 | 0.01 |
| 25 | 0.025 |
| 50 | 0.05 |
| 100 | 0.1 |
Compare one erg/(cm²·s) with other units
| Target unit | Equivalent of 1 erg/(cm²·s) | Definition guide |
|---|---|---|
| Watts per square meter (W/m²) | 0.001 | Read definition |
| Kilowatts per square meter (kW/m²) | 0.000001 | Read definition |
| Watts per square centimeter (W/cm²) | 1e-7 | Read definition |
| Milliwatts per square centimeter (mW/cm²) | 0.0001 | Read definition |
What the unit means
The unit erg/(cm²·s) expresses energy per unit area per unit time, which is heat flux or, for radiation, flux density. It comes from the centimeter-gram-second system, where the erg is the unit of energy and equals 10^-7 J exactly. The factor to SI is 0.001 W/m², which follows from two conversions: 1 erg/s equals 10^-7 W, and 1 cm² equals 10^-4 m², so 1 erg/(cm²·s) equals 10^-7 divided by 10^-4, or 10^-3 W/m². In the other direction, 1 W/m² equals 1,000 erg/(cm²·s), and 1 W/cm² equals 10^7 erg/(cm²·s). The word erg comes from the Greek ergon, work, and the CGS system was promoted in the 1870s by the British Association for the Advancement of Science. SI replaced it in most fields, but CGS units remain common in astrophysics and in some branches of physics and geology.
Reading the compound label
The unit has four parts: an energy unit, a length unit squared, a time unit and a dot that links the area and time denominators. Both denominator components must be kept. Energy per area alone, erg/cm², is a fluence or surface energy, and it does not describe a rate. Energy per time alone, erg/s, is power. Only when both area and time appear in the denominator does the unit describe flux. Dropping the seconds would turn a rate into an amount, and dropping the area would turn a flux into a power. The superscript 2 on centimeters applies to the unit alone, so cm² is one square centimeter, not a centimeter doubled. In plain-text sources the unit may appear as erg cm^-2 s^-1 or erg/cm2/s, and all of these are the same unit. Recognize the forms before applying the factor.
Converting to watts per square meter
To convert, multiply the CGS value by 0.001 to get W/m². A flux of 5,000 erg/(cm²·s) equals 5 W/m². A flux of 2.5 erg/(cm²·s) equals 0.0025 W/m², and 1.361 × 10^6 erg/(cm²·s) equals 1,361 W/m². To go the other way, multiply W/m² by 1,000. For heat transfer in building engineering, 1 Btu/(h·ft²) equals about 3.1546 W/m², which is 3,154.6 erg/(cm²·s). The conversion to W/cm² divides by 10^7, so 5,000 erg/(cm²·s) is 0.0005 W/cm². These steps are exact multiples of 10 for the CGS to SI link, with the Btu factor depending on which Btu definition applies. A round trip with the building unit: 10 Btu/(h·ft²) is about 31.546 W/m², or 31,546 erg/(cm²·s), and 1 kW/m² is 10^6 erg/(cm²·s). Always check the direction of the conversion by magnitude: the CGS number is larger than the SI number, since the CGS unit is smaller by a factor of 1,000.
Solar irradiance as a reference value
A well-known flux in CGS units is the solar constant, the total solar irradiance at one astronomical unit from the Sun. The International Astronomical Union adopted a nominal value of 1,361 W/m² in 2015, which corresponds to 1.361 × 10^6 erg/(cm²·s). Astronomers writing in CGS give this as about 1.36 × 10^6 erg cm^-2 s^-1. Actual measured values vary slightly with solar activity, and satellite instruments report values near 1,361 W/m². The flux falls with the square of the distance from the Sun, so at twice the distance it is a quarter of the value. For heat flux through a solid, the numbers are much lower: a flux of 100 W/m² through a wall is 100,000 erg/(cm²·s). The solar number is a convenient benchmark for judging whether a CGS value is huge or modest.
Blackbody radiation in CGS form
The Stefan-Boltzmann law gives the power radiated per unit area by an ideal blackbody as σT⁴. The constant is σ ≈ 5.670374419 × 10^-8 W/(m²·K⁴) in SI units, and in CGS units it is 5.670374419 × 10^-5 erg/(cm²·s·K⁴), larger by the same factor of 1,000. At 300 K the flux is σ × 300⁴ = 459.3 W/m², which is 459,300 erg/(cm²·s). At 5,772 K, the nominal effective temperature of the Sun, the flux is about 6.29 × 10^7 W/m², or 6.29 × 10^10 erg/(cm²·s). The CGS form is familiar in astrophysics papers. When using a formula from a CGS source with SI data, convert the constants and the input quantities together, not just the answer, so the units remain consistent through the algebra.
From flux to power
Heat flux describes a rate per area. To get total power, multiply by the area over which the flux applies. A flux of 5 W/m², which is 5,000 erg/(cm²·s), applied over 2 m² delivers 10 W. In CGS terms, the same area is 20,000 cm², and 5,000 erg/(cm²·s) × 20,000 cm² equals 10^8 erg/s, which is 10 W since 1 W equals 10^7 erg/s. A flux alone does not give the area, which matters because the same flux can correspond to very different powers. A flux of 1,000 erg/(cm²·s) over a 1 cm² thermal sensor is 1,000 erg/s, or 0.0001 W, while over 100 m² it is 100 W. Always record the area and the direction of heat flow with the flux. Energy over a period needs a further multiplication by time, so total energy equals flux times area times duration.
Flux versus flux density and terminology
Terminology differs between fields. Engineers speak of heat flux density or simply heat flux for energy per area per time. Astronomers use flux for the energy crossing a unit area per time and flux density for flux per unit frequency or wavelength, with units such as erg/(cm²·s·Hz). The jansky, a radio-astronomy unit, equals 10^-23 erg/(cm²·s·Hz), which is 10^-26 W/(m²·Hz). Those spectral quantities carry an extra denominator and do not convert with the plain factor of 0.001. The plain heat-flux quantity has no spectral denominator. If a source writes erg/(cm²·s·Å) or erg/(cm²·s·Hz), the extra component marks a different quantity, and converting it as ordinary heat flux would be wrong. Compare the full unit string before applying the factor.
A worked example from reading to power
Suppose a laboratory report from a CGS-trained group lists a surface heat loss of 3,200 erg/(cm²·s) for a panel with an area of 1.5 m². First convert the flux: 3,200 × 0.001 = 3.2 W/m². Then multiply by the area: 3.2 × 1.5 = 4.8 W. In energy over an hour, 4.8 W × 3,600 s equals 17,280 J, or 17.28 kJ. Checking in CGS terms, 1.5 m² is 15,000 cm², and 3,200 × 15,000 equals 4.8 × 10^7 erg/s, which is 4.8 W. A second case, an incoming radiation flux of 8.0 × 10^5 erg/(cm²·s), equals 800 W/m², a plausible value for sunlight on a clear day with the sun well above the horizon. The figures here are illustrative and do not come from a specific experiment. Both calculations rely only on exact powers of ten.
Heat flux in practice
Heat flux sensors, sometimes called heat flux gauges or thermopile plates, output a voltage proportional to the flux through the sensor, and calibration constants relate volts to W/m² or, in older equipment, to other units. Building science uses W/m² for envelope losses. Industrial furnace and combustion studies commonly use kW/m² or MW/m², and spacecraft thermal protection uses values of W/cm². The CGS unit is mostly in older literature and in astrophysics. Whatever unit applies, the measured flux depends on the surface temperature, emissivity, convection and the sensor mounting, and a unit conversion does not touch any of those. When reading an old paper, convert the numbers once, keep both versions in your notes and mark the original unit, so any later check against the source can be done by direct comparison.
Notation and precision
The unit can be written erg/(cm²·s), erg cm^-2 s^-1 or erg/cm²/s. The parenthesized form is the clearest because it makes both denominator parts explicit, and it keeps both denominator components visible. Without parentheses, erg/cm²·s is ambiguous, since a reader might take the s as a multiplier in the numerator. The symbol erg is lowercase, and the plural is the same as the singular. In spreadsheets, put the unit in the column header or a separate field. The factor of 0.001 is exact, so the conversion adds no uncertainty. The result has the same significant figures as the input: 3,200 erg/(cm²·s) with two significant figures becomes 3.2 W/m², and writing 3.200 W/m² would overstate precision. Source flux precision should be retained, and rounding to display should come only at the end.
Why astronomers still use CGS flux
Astrophysics grew up around CGS units, and large archives, catalogs and textbooks still quote luminosity in erg/s and flux in erg/(cm²·s). The IAU nominal solar luminosity is 3.828 × 10^33 erg/s, equal to 3.828 × 10^26 W. Spreading that luminosity over a sphere of radius one astronomical unit, 1.495978707 × 10^13 cm, with area 4πd² of about 2.812 × 10^27 cm², gives a flux of 3.828 × 10^33 divided by 2.812 × 10^27, which is 1.361 × 10^6 erg/(cm²·s). That is the same 1,361 W/m² that the SI form gives, so the two systems agree once the factor of 1,000 is applied. Reading older papers therefore requires conversion of every constant and data column, not only the headline numbers. Keeping a short table of the exact factors, such as 10^-7 J per erg and 10^-4 m² per cm², avoids rederiving them for each document.
Precision and checking
- Keep source flux precision.
- Retain both denominator components.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Heat flux density converter
- Ergs per square centimeter second to Watts per square meter converter
- Ergs per square centimeter second to Kilowatts per square meter converter
- Ergs per square centimeter second to Watts per square centimeter converter
- Ergs per square centimeter second to Milliwatts per square centimeter converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.