A CGS unit meets a practical one
The erg per square centimeter per second belongs to the centimeter-gram-second system of units, which dominated physics and astronomy before the SI took over. Older papers on radiation, solar physics and heat transfer still quote fluxes in it. The milliwatt per square centimeter is a practical modern unit that appears on the data sheets of photodiodes, UV lamps, solar simulators and laboratory radiometers. This converter bridges the two. You enter a flux in erg/(cm²·s), and the result is the same flux in mW/cm². Both units have square centimeters in the denominator, so the area never needs converting. Only the power part changes, from ergs per second to milliwatts. Because the relationship is a clean power of ten, the conversion is exact, and the tool is mainly a safeguard against putting the decimal point in the wrong place when a paper from the 1960s meets a 2020s instrument manual.
How the factor 0.0001 arises
The erg is the CGS unit of energy, defined as one dyne acting through one centimeter. The dyne is 10 to the minus 5 newton and the centimeter is 10 to the minus 2 meter, so one erg equals 10 to the minus 7 joule exactly. One erg per second is therefore 10 to the minus 7 watt, which is 10 to the minus 4 milliwatt. The area is the same in both units, so nothing else changes, and 1 erg/(cm²·s) equals 0.0001 mW/cm². Going the other way, 1 mW/cm² is 10,000 erg/(cm²·s). A second route through SI units gives the same answer: 1 erg/(cm²·s) is 0.001 W/m², and 1 mW/cm² is 10 W/m². The default of 10 erg/(cm²·s) therefore converts to 0.001 mW/cm², or 0.01 W/m². The unit definitions come from the BIPM and NIST tables cited on the page.
Solar irradiance as a worked example
Sunlight gives a familiar benchmark. The nominal total solar irradiance above the atmosphere, adopted by the IAU in its 2015 resolution on nominal solar values, is 1,361 W/m². In CGS units that is 1,361,000 erg/(cm²·s), and converting with this tool gives 136.1 mW/cm². At the ground, with the sun overhead and a clear sky, the irradiance reaches roughly 1,000 W/m², the reference level used for testing photovoltaic panels. That equals 100 mW/cm² and 1,000,000 erg/(cm²·s). Entering 1,000,000 returns 100, which makes a handy reference point. A solar cell test report quoting 100 mW/cm² and a 1960s astrophysics paper quoting 10 to the 6th erg/(cm²·s) describe the same standard sun. The values are rounded benchmarks, and actual irradiance varies with latitude, season, altitude and weather.
Human heat output and building surfaces
Heat flux numbers on a human scale show why milliwatts per square centimeter is a handy size. A resting adult produces on the order of 100 W of heat over about 1.8 m² of skin, which is roughly 55 W/m². That is 5.5 mW/cm², or 55,000 erg/(cm²·s). The figures are illustrative averages and individuals differ. Building walls carry far less in steady conditions. A well-insulated wall may lose only a few watts per square meter, which is a few tenths of a milliwatt per square centimeter. In the CGS unit those values look like thousands of ergs, which hints at why the system was replaced for engineering work: the numbers are large and unfamiliar. The conversion makes the same data readable in the unit people see on instrument displays.
Reading a radiometer or UV meter
Many radiometers display irradiance in mW/cm² or µW/cm², and their calibration certificates sometimes list the factor in other units. A UV curing lamp might be specified at 500 mW/cm² at a working distance, a figure that equals 5,000,000 erg/(cm²·s). A lower reading of 0.25 mW/cm² corresponds to 2,500 erg/(cm²·s). The converter is useful when a standard or protocol written in one unit has to be checked against an instrument that reports in another. Remember that radiometers are sensitive over a limited wavelength range and are calibrated against a particular source, so the reading is the flux in the sensor band, not the total power across all wavelengths. The unit conversion does not change that limitation.
Energy dose versus power flux
Power per area and energy per area are different quantities, and mixing them is a common mistake in exposure work. Multiplying the flux by time gives the dose, or fluence. A flux of 2 mW/cm² applied for 30 seconds delivers 60 mJ/cm². In CGS units, the same dose is 600,000 erg/cm². Exposure limits and curing requirements are often expressed as doses in mJ/cm² or J/cm², while lamps and sensors report flux. The converter changes only the flux unit. To get a dose, you must multiply by the exposure time yourself. Writing the units next to every number keeps the distinction clear: if the unit has seconds in the denominator, it is a rate, and if it does not, it is an amount.
The erg and the CGS system
The CGS system was promoted in the 1870s by the British Association for the Advancement of Science and came to dominate scientific literature for decades. Its energy unit, the erg, takes its name from the Greek word for work. The system is convenient in electromagnetism and astrophysics, where values on the scale of ergs match natural quantities, and it persists in astronomy, where luminosities are often given in erg/s and fluxes in erg/(cm²·s). A typical star such as the Sun has a luminosity of about 3.8 times 10 to the 33rd erg/s, a number that would be 3.8 times 10 to the 26th W in SI. Because many classic papers use these units, a converter to practical units is a regular need for students reading the older literature.
Rounding and scale
The factor of 0.0001 is exact, so the result is limited only by the precision of your input. Because the output unit is 10,000 times larger than the input unit, results are small. A flux of 50 erg/(cm²·s) is 0.005 mW/cm². If you prefer a scale that avoids many zeros, convert to µW/cm² by multiplying the mW/cm² value by 1,000, so that 0.005 mW/cm² becomes 5 µW/cm². Keep the same number of significant figures as the source: if the original paper gave a flux as 3.2 times 10 to the 5th, the converted value of 32 mW/cm² has two significant figures. Extra digits would suggest a measurement quality that the data do not have.
Converting a value from an older paper
Suppose a laboratory report from the 1970s lists a surface heat flux of 4.2 times 10 to the 4th erg/(cm²·s). Enter 42000 and the converter returns 4.2 mW/cm². In SI terms that is 42 W/m², since 1 mW/cm² is 10 W/m². A second value in the same paper, 7,500 erg/(cm²·s), becomes 0.75 mW/cm² and 7.5 W/m². Working through a table like this takes a minute, but the real benefit is consistency: every entry gets the same factor, so the relative sizes of the values are preserved and any suspicious entry stands out. Keep the original CGS figures in a column next to the converted ones when you cite such a source, so that a reader can trace the number back to the page of the paper where it appeared.
Fluxes in astronomy
Astronomers still report bolometric fluxes, the total energy per area per time across all wavelengths, in erg/(cm²·s). The Sun delivers about 1.361 times 10 to the 6th erg/(cm²·s) at Earth's distance, which matches the 1,361 W/m² nominal value. Faint stars and galaxies appear in the literature with fluxes of 10 to the minus 12 or 10 to the minus 14 erg/(cm²·s). Converting such a value to mW/cm² gives 10 to the minus 16 or 10 to the minus 18, numbers that illustrate how small the signals are. A different family of units describes flux per unit frequency or wavelength, such as the jansky, which is 10 to the minus 26 W/(m²·Hz). Those are spectral quantities, and this converter does not handle them. It converts a total flux in power per area.
Quick mental rules
Three shortcuts cover most checks. To get W/m² from erg/(cm²·s), divide by 1,000. To get mW/cm² from W/m², divide by 10. Chaining them, divide the erg figure by 10,000 to get mW/cm², which is the factor of 0.0001 in the converter. For 30,000 erg/(cm²·s), the steps give 30 W/m² and 3 mW/cm². For 2,000,000, they give 2,000 W/m² and 200 mW/cm², about twice the standard sun. If the result of a conversion is not about one ten-thousandth of the input, an error has crept in. A reading error of this kind is easy to make when handling data copied from a table in a scanned paper, where exponents are small and a superscript can be misread. Rechecking one value with the shortcut takes seconds and can save a long debugging session later.
Radiometer limits the unit change cannot fix
The converter changes one unit of power per area into another and does nothing beyond that. It does not compute heat transfer through a wall, estimate radiative heating, apply exposure limits or compare a reading with any safety guideline. It also does not correct a radiometer reading for wavelength, angle or distance. Results describe the same flux in a different unit. Questions about thermal comfort, building compliance, optical safety or installation limits need the relevant standards and a qualified person, and the page makes no claim about them.