Twelve orders of magnitude on one page
A kilowatt is the scale of a heater or an induction hob, and a nanowatt is the scale of a chip asleep. Datasheets for some microcontrollers and wireless chips list standby draw in the nanowatt range, and engineers who compare a design with the mains equipment around it need both in one unit. This page multiplies by one trillion and shows the result. The default of 10 kW gives 10,000,000,000,000 nW. The page also works backward, so a sleep figure of 750 nW can be written as 0.00000000075 kW, which shows in a vivid way how small the figure is against any household load.
Building the factor in two steps
Go from kilowatts to watts first, which multiplies by 1,000, then from watts to nanowatts, which multiplies by 1,000,000,000 because nano means 10^-9. The product is 10^12, so nW = kW × 1,000,000,000,000. NIST SP 811 lists the SI prefixes, and the BIPM SI Brochure is the primary source. The result of a conversion with this factor is exact in decimal terms. Standard double-precision numbers in spreadsheets hold about 15 to 16 significant digits, which is enough here because the inputs are short decimals, but results above 9 quadrillion exceed the range where every whole number can be stored exactly in such formats.
Ratio thinking: heater against sleeping sensor
Take a 1.5 kW heater and a sensor that sleeps at 750 nW. In nanowatts the heater is 1,500,000,000,000 nW, and dividing by 750 gives a ratio of 2,000,000,000. The heater draws two billion times as much power as the sensor in sleep. Looking at both in one unit makes this obvious in a way that 1.5 kW against 0.00000000075 kW does not. When an engineer reports that sleep power fell by half, from 750 nW to 375 nW, the saving is 375 nW, a quantity that fits on a line of a spreadsheet, whereas in kilowatts it would be written with many zeros and easily misread.
Reading a datasheet figure
Low-power datasheets specify conditions next to the sleep figure: supply voltage, temperature, which memory is retained and whether a clock is running. A value in nanowatts without those conditions is hard to use. Some sheets list current in nanoamps instead, and then power equals current times voltage. For example, 250 nA at 3 V is 750 nW. The page does not use current. If you have nanoamps, multiply by the supply voltage first, then enter the nanowatt result with the nanowatt unit selected, and convert to the other unit of your choice. Keeping the conditions with the number keeps comparisons honest between chips. Two sheets that both claim a few hundred nanowatts may differ in what stays powered, so a note on retained memory or a running clock is part of the figure. When you build a comparison table for a project, add a column for these conditions and fill it from the datasheet text before you convert any entry.
Energy over a year at nanowatt draw
Small powers can still add up over long times, and the numbers are instructive. A device that draws 750 nW continuously uses 750 × 10^-9 W × 8,760 hours, which is 0.006570 Wh in a year, or 6.57 mWh. A typical small coin cell stores hundreds of milliwatt-hours, so such a draw leaves most of its capacity untouched, and self-discharge of the cell becomes the limit instead. The page helps by putting the power in the same units as the datasheet. The energy step needs a time, which you multiply in separately, and an energy converter handles the unit change from there.
Harvested energy and indicators
Energy harvesting from small solar cells, vibration or radio waves delivers microwatts in many cases and, for the weakest sources, nanowatts. A source of 500 nW cannot run most circuits continuously, but a storage capacitor can collect that power over minutes and release it in a short burst. A designer compares the source average with the load average, and both must be in the same unit. If you have a panel rated in kilowatts and a small harvester in nanowatts, the page links the two and shows how far apart they are. Real harvesters depend on lighting and conditions, so a figure should always come with its test setup.
Prefix traps with nano
Nano (n, 10^-9) is easy to confuse with micro (µ, 10^-6) because both appear in small-signal electronics. A thousand nanowatts make one microwatt. Another trap is the uppercase N, which is not a power unit symbol at all and is used for newtons. Because nW values are so small, a mistake of three orders of magnitude matters, so check the unit label on the result before copying it. When you transcribe a datasheet figure into a spreadsheet, include the prefix in the column header rather than relying on memory. The converter menu lists nanowatts and microwatts separately for this reason.
Precision and verification
The converter keeps the factor at full precision and rounds only the displayed result, to at most 12 significant digits. To verify a result by hand, move the decimal point twelve places to the right, which for 1.5 kW gives 1,500,000,000,000 nW. To reverse, move twelve places to the left or set nanowatts as the source and kilowatts as the target. For instance, 5,000 nW is 0.000000005 kW. If you feel unsure about the count of zeros, convert in two stages through watts and compare, since 5,000 nW is 0.000005 W and 0.000005 W is 0.000000005 kW.
Limits of the number
A nanowatt figure belongs to a particular device state, and the page cannot tell which. It does not model supply voltage, duty cycle, leakage over temperature or any conversion losses between a battery and the chip. Measuring nanowatt power in practice needs specialized instruments, because ordinary meters have resolution far coarser than that. When you compare two datasheet values, check that both were measured under similar conditions. Use the page to align units and to check arithmetic, and rely on the manufacturer documentation and on your own measurement for design decisions. A practical habit is to record the unit prefix in the name of every spreadsheet column, such as sleep_nW or heater_kW, so that no later formula multiplies a nanowatt figure by a value that assumed microwatts. That one habit prevents most of the errors that appear in small-power budgets.