Neighbors on the prefix ladder

Femto and pico are adjacent in the sequence of thousands, so this is the smallest jump a femtocoulomb converter can make. It is also one of the most frequently needed. Charge amplifiers for piezoelectric sensors report sensitivity in picocoulombs per newton or per g of acceleration, while the noise and offset of the electronics are given in femtocoulombs. Partial discharge testers for cables and transformers display apparent charge in picocoulombs. A technician who sees 3,000 fC on one screen and 3 pC on another needs to know they match, and this converter confirms it. A factor of one thousand is the kind of gap where a slip is easy to make and hard to spot.

Definition and exact factor

The coulomb is the SI unit of electric charge and equals one ampere second, as set out in the SI Brochure. Pico denotes 1e-12 and femto denotes 1e-15, both exact. Therefore 1 pC is exactly 1,000 fC and 1 fC is exactly 0.001 pC. The page formula, pC = fC × 0.00100000000000, expresses the same relation with trailing zeros. Because the factor is a pure power of ten, the conversion is lossless on paper: moving the decimal point three places to the left converts fC to pC, and three places to the right converts pC to fC. Any odd-looking digits that appear in a result are the output of floating point arithmetic.

Default result for 10 fC

With 10 fC entered, the output is 0.010000000000000002 pC. The trailing 2 at the seventeenth digit is floating point noise, and the intended answer is 0.01 pC. A value of 0.01 pC is small even for sensitive equipment. A partial discharge measurement typically needs a resolution of a pC or better, so 10 fC would sit well below the useful range of a high-voltage test set, whereas a charge amplifier built around a low-noise FET input can resolve it. The converter gives the number, and the context of your instrument tells you whether that number is meaningful. Charge amplifiers are usually rated for a full-scale range such as 10,000 pC, and the same chip may resolve a few fC, so a three or four digit exponent separates its smallest and largest useful values.

Sensor cables and charge leakage

Piezoelectric charge signals are delicate because insulation resistance bleeds them away. A cable with a leakage of 1 pA removes 1 pC every second, which equals 1,000 fC per second. In a low-frequency vibration measurement, that drift can be larger than the signal itself, so charge amplifiers include a long time constant and specify a lower frequency limit. Expressing the loss in the same unit as the signal, using this page, turns the question into a simple comparison of 1,000 fC lost per second against a signal of a few thousand fC per cycle.

Example from a piezoelectric accelerometer

Piezoelectric accelerometers are rated by charge sensitivity, often in the range of a few to a few hundred pC per g. Take an illustrative sensor with 2.5 pC per g. A vibration of 0.5 g then produces 1.25 pC, which is 1,250 fC. If the charge amplifier has an input-referred noise of 20 fC, the signal-to-noise ratio is 62.5, or about 36 decibels in amplitude terms. Entering 2,500 fC into this converter returns 2.5 pC, confirming the sensitivity figure. The numbers here are illustrative, and a real sensor will have its own calibration certificate listing its sensitivity at a stated frequency.

Going from picocoulombs to femtocoulombs

The reverse conversion multiplies by 1,000. A reading of 0.8 pC equals 800 fC, 5 pC equals 5,000 fC, and 120 pC equals 120,000 fC. It is helpful to convert the larger unit down whenever you need to compare against a noise floor listed in femtocoulombs, because comparing whole numbers is less error-prone than comparing decimals with leading zeros. In a partial discharge test, the IEC 60270 method specifies calibration with a known charge injected into the test object, with the result quoted in picocoulombs. A reading of 5 pC on the tester is 5,000 fC, which makes its relation to a 20 fC amplifier noise figure visible at a glance. The ratio of 250 to 1 between them shows the tester signal sits well above the amplifier noise floor.

Significant figures and stray digits

The factor of 1e-3 is exact, but binary arithmetic cannot represent 0.001 exactly, which is why the default result ends in a stray digit. When you read the result, keep as many significant figures as your input had. Ten femtocoulombs has two, so 0.010 pC is a fair rendering, and 0.0100000000 is not. In reports, state the unit and the number of significant figures in the original measurement. That makes the converted number easy to check and prevents later readers from assuming the precision of the instrument is higher than it is.

pC versus pF

The symbols pC and pF are one letter apart and measure different things. A picocoulomb is a quantity of charge, a picofarad is a capacitance, and the two are linked by voltage: Q = C × V. A 1 pF capacitor charged to 1 V holds 1 pC, which is 1,000 fC. This relation helps check that a result is plausible, because a 5 pF stray capacitance at the input of an amplifier that sees 10 mV swings carries 50 fC. The two units look alike on a printed schematic, so confirm which one the source gives before entering a value. This page converts charge only and cannot convert farads.

Sensor calibration and partial discharge claims

The page converts a quantity between two prefixes of the same unit. It does not calibrate a sensor, certify a partial discharge reading, or compare a result with a test standard. The sources behind the unit definitions are the SI Brochure and NIST SP 811, and neither says anything about instrument performance. If your measurement feeds a compliance report, take the acceptance limits from the relevant standard or the equipment manufacturer. The converter is intended for restating a known value in the prefix that fits the document, and for catching a factor of 1,000 error before it spreads through a calculation. Because the two prefixes are neighbors, it is also a convenient first step before a longer chain such as fC to nC or fC to mC on the related converters.