Charge amounts under one picocoulomb
Analog switches, sample-and-hold circuits and small sensors move charge in quantities of fractions of a picocoulomb, and their data sheets quote the value in femtocoulombs. A CMOS switch might list a charge injection of 0.5 pC in one place and 500 fC in another. This page multiplies the picocoulomb value by 1,000 so that a measurement from a charge amplifier can sit next to a specification written in fC. It is aimed at circuit designers, lab technicians and students who read data sheets from several makers and have to line up their units before comparing parts. Mixing pC and fC in a parts shortlist is a common reason for ranking a worse switch above a better one, so the conversion is worth doing before any table is shared. Write the unit in the column header and keep the cells numeric, so a later sort puts 40 fC ahead of 2,500 fC as it should.
0.5 pC is 500 fC and 750 fC is 0.75 pC
Pico is 10^-12 and femto is 10^-15 in the SI Brochure (BIPM) and NIST SP 811, so 1 pC is exactly 1,000 fC. The formula is fC = pC × 1,000. Move the decimal point three places to the right: 0.5 pC is 500 fC, 2.5 pC is 2,500 fC and 0.04 pC is 40 fC. In the other direction, 750 fC is 0.75 pC. The result is always larger than the input because the femtocoulomb is the smaller unit. If the page shows a shrinking number, the menus are the wrong way round. The default displays 9,999.999999999998 in some views, which is a floating-point artifact and means 10,000 fC.
Ten picocoulombs in femtocoulombs
The default of 10 pC gives 10,000 fC. That is a plausible size for charge injection in a general-purpose analog switch, which is often in the single or double digits of picocoulombs. The best low-injection parts specify under 1 pC, which is under 1,000 fC. A smaller case is a detector pulse of 0.2 pC, which is 200 fC. Entering both values in the same unit lets you rank parts quickly. If your list spans from 50 fC to 12 pC, converting everything to fC gives a column from 50 to 12,000 that is easy to sort and compare, without a mixture of decimals and whole numbers.
Q = C × V for small capacitors
Charge equals capacitance times voltage. A 1 pF capacitor at 1 V holds 1 pC, which is 1,000 fC. A 10 fF capacitor, typical of a node in an integrated circuit, holds 10 fC at 1 V, and 33 fC at 3.3 V. A 100 fF parasitic capacitance charged to 1.8 V stores 180 fC. Designers use this relation to estimate how much charge a switch or a gate moves when it changes state. The page does not compute the product, but it gives a quick way to move between pC and fC once you have it. Keep the voltage with the number, since the charge depends on it. For a 2 pF load at 2.5 V the stored charge is 5 pC, which is 5,000 fC, and a switch injecting 500 fC would disturb it by one tenth of that amount, a useful ratio to estimate before layout.
Charge injection in analog switches
When a transistor switch turns off, some of the charge in its channel and some charge coupled through its gate capacitance ends up on the load. The resulting step in voltage equals the injected charge divided by the holding capacitor. With 500 fC injected into a 1 nF hold capacitor, the step is 500 fC ÷ 1 nF = 0.5 mV. With a 10 pF capacitor, the same charge produces 50 mV, a hundred times more. That is why sample-and-hold circuits use larger capacitors when accuracy matters, at the cost of speed. Data sheets list injection in pC or fC for a given test condition, which you should compare using the same unit.
Counting electrons
The elementary charge is 1.602176634 × 10^-19 C exactly. One femtocoulomb corresponds to about 6,241 electrons, and one picocoulomb to about 6.24 million. A detector pulse of 200 fC therefore carries about 1.25 million electrons. Image sensors and radiation detectors describe signals in electrons, and charge amplifiers in fC. The conversion between the two is a division by the elementary charge, which the page does not perform, but knowing the scale helps you judge noise: a readout noise of 100 electrons is about 0.016 fC. These are illustrative numbers for a generic device and the data sheet gives the real ones.
Piezoelectric and capacitive sensing
A piezoelectric film or crystal produces charge when it deforms, and tiny forces generate charges of femtocoulombs. A sensor of 2 pC/N pressed with 0.1 N makes 0.2 pC, or 200 fC. Charge amplifiers turn that into a voltage, and leakage through cable insulation can swamp the signal. Capacitive sensors work similarly: a change of 1 fF at 3.3 V moves 3.3 fC. Seeing signals in fC makes it clear how small the margin is and why shielding and guarding are needed. The conversion is simple, and the design effort goes into keeping the input node clean. Guard traces, short leads and a stable temperature all help, and so does waiting for the signal to settle before reading it, because charge settles slowly in high-impedance nodes.
Reporting small charges
In a report or a table, give charge in the unit that keeps numbers between 1 and 1,000. Values such as 0.0003 pC should be written 0.3 fC. If a table includes entries across several decades, add a note about the unit in the header and avoid mixing pC and fC in one column. Round to the number of digits the measurement supports: a reading from a meter with 0.1 pC resolution should not be reported as 2,347 fC. When you convert 2.3 pC, the result 2,300 fC is acceptable, and a string like 2,347.000 fC suggests precision that does not exist.
Charge from capacitance and voltage is a step before this one
The page restates a charge in another unit, and the factor of 1,000 is the same for every value you type. It does not compute charge from capacitance and voltage, estimate injection, calibrate an amplifier or judge whether a switch meets a requirement. Take those answers from the data sheet, your test setup and the circuit analysis.