Field strength in reports and test plans

A field-strength meter or a site survey for a radio transmitter often reports in millivolts per meter, and a product test plan or an equipment datasheet states immunity levels in volts per meter. A technician who needs to know whether a measured field is above or below the level a device was tested at needs both numbers in the same unit. This page divides the mV/m value by 1,000 and shows V/m. The unit itself is the SI unit of electric field strength, a voltage per unit length, and the prefix is all that changes. For many people this page is the only step needed between a meter display and the line in a specification.

Why 1,000 mV/m make 1 V/m

The milli prefix means 10^-3, so 1 mV/m is 0.001 V/m and the page divides by 1,000. The equivalence with newtons per coulomb follows from the definition of the volt, so electric field can be stated in either unit. Only the measured field strength carries uncertainty, not the factor of 1,000. To check a result, move the decimal point three places left: 750 mV/m is 0.75 V/m and 12 mV/m is 0.012 V/m. In reverse, 3 V/m is 3,000 mV/m. If the converted number is larger than the input, the direction was chosen wrongly. The page also lists volts per centimeter and kilovolts per meter for sources that use another scale.

Ten millivolts per meter in volts per meter

With 10 mV/m the page returns 0.01 V/m. A field of 500 mV/m is 0.5 V/m, a value of 0.25 mV/m is 0.00025 V/m, and 3,200 mV/m is 3.2 V/m. In the reverse direction 10 V/m equals 10,000 mV/m. The numbers show how quickly the scales separate: typical immunity test levels of a few volts per meter are hundreds or thousands of times the levels of weak broadcast signals. Keep results with leading zeros in exponent form when copying them into a database, so that 2.5 × 10^-4 V/m cannot lose a digit in transit.

EMC immunity levels

Standards for electromagnetic compatibility, such as IEC 61000-4-3 for radiated immunity, specify test field levels in volts per meter. Common levels are 1, 3 and 10 V/m, with higher levels for harsh environments. A product that passes at 3 V/m has been exposed to a field of 3,000 mV/m during the test, and one tested at 10 V/m saw 10,000 mV/m. A site survey that finds 40 mV/m near a transmitter, which is 0.04 V/m, shows a field far below those test levels. Whether a product is suitable for a site depends on the standard and the frequency range, which this page does not evaluate.

Reading broadcast field strength

Coverage maps for FM and TV services list field strength in dBµV/m, and receivers are specified by the field they need. Converting between dBµV/m and V/m uses a logarithm: the level in µV/m is 10 raised to the dB value divided by 20. A value of 60 dBµV/m is 1,000 µV/m, which is 1 mV/m or 0.001 V/m. A strong local signal of 100 dBµV/m is 100,000 µV/m, or 0.1 V/m. The page works only with linear units, so convert from dB first and then use it for the prefix change. Remember that coverage values are usually given at a fixed height above ground, for example 10 m, and the antenna at a house is likely to see a different value.

From field strength to antenna voltage

A short antenna in a uniform field picks up a voltage roughly equal to the field times the effective length. In a field of 10 mV/m, an antenna with an effective length of 1.5 m would give about 15 mV open circuit, and 0.01 V/m times 1.5 m is 0.015 V. This is an idealized estimate that ignores matching, ground effects and the loss in the cable. It helps to see why receivers need low-noise amplifiers when fields are only a few millivolts per meter. Treat the example as illustrative, since real antennas have gain patterns and efficiencies that change the result substantially, and no unit conversion can supply them.

Converting volts per meter back to millivolts per meter

To convert the other way, select volts per meter as the source and millivolts per meter as the target. A reading of 0.04 V/m equals 40 mV/m, 1 V/m equals 1,000 mV/m, and 30 V/m equals 30,000 mV/m. The page multiplies by 1,000. A field of 100 V/m, close to the fair-weather atmospheric field near the ground, is 100,000 mV/m. Using the volts per centimeter option, 1 V/cm is 100 V/m. Always record the unit with the value, since a log that mixes mV/m and V/m can look consistent while being off by 1,000.

RMS, peak and field components

Field strength reports for sinusoidal signals can be given as RMS or peak values, which differ by a factor of about 1.414. EMC standards usually quote the unmodulated RMS level, and may require amplitude modulation on top, which raises the peak. A three-axis probe reports the resultant of three components, while a single-axis antenna reports one. Before comparing a survey value in mV/m with a test level in V/m, check which of these a source uses. The conversion between prefixes is identical in all cases, but the comparison only holds if both values mean the same thing.

A small table for a test report

A test report may list the field at a site in several units so that readers with different backgrounds can follow it. For an illustrative value of 250 mV/m, the table would read 0.25 V/m, 0.0025 V/cm and 0.00025 kV/m. For a test level of 10 V/m it would read 10,000 mV/m, 0.1 V/cm and 0.01 kV/m. Prepare such rows in one pass with the page and check each against the original by moving the decimal point. Keep a note of the measurement height and antenna polarization, since the same transmitter can give very different readings at different heights. The conversion is exact, so the result has the significant digits of the entry. Field probes carry uncertainties of a few dB at best, which is tens of percent, so a result such as 0.01000 V/m claims too much. The page does not convert from dBµV/m, does not estimate field strength from transmitter power and distance, and does not determine product compliance. It changes the prefix of an electric field value and nothing else.