Measurement basis
This quantity retains voltage per length.
Definition conventions
Prefixes use SI decimal powers. The selections remain within the electric-field quantity.
Conversion method
Keep V/m unchanged for the reference; use a target field factor for another unit.
Reference equivalent of V/m
1 V/m = approximately 1 V/m.
Recorded scale factors: 1 for V/m; 1 for V/m.
Worked example
Known input: 10 V/m. Reference equivalent: 10 V/m. The return conversion gives approximately 10 V/m.
The example retains the per-meter component.
Common reference values
| Input (V/m) | Reference equivalent (V/m) |
|---|---|
| 1 | 1 |
| 5 | 5 |
| 10 | 10 |
| 25 | 25 |
| 50 | 50 |
| 100 | 100 |
Compare one V/m with other units
| Target unit | Equivalent of 1 V/m | Definition guide |
|---|---|---|
| Volts per centimeter (V/cm) | 0.01 | Read definition |
| Kilovolts per meter (kV/m) | 0.001 | Read definition |
| Kilovolts per centimeter (kV/cm) | 0.00001 | Read definition |
| Millivolts per meter (mV/m) | 1000 | Read definition |
The SI unit of electric field strength
The volt per meter, V/m, is the coherent SI unit of electric field strength. It equals one newton per coulomb, N/C, so a field of 1 V/m pushes a charge of 1 coulomb with a force of 1 N. In base units it is kg m s⁻³ A⁻¹. Between two parallel plates the field is the voltage divided by the spacing, so 12 V across a 2 mm gap gives 6,000 V/m, which is 60 V/cm. An electron in a field of 1 V/m feels a force of 1.602 x 10^-19 N, the elementary charge times the field. The unit measures a field in space and says nothing about the voltage source that creates it. A reading of 6,000 V/m can come from a small supply across a tiny gap or from a very high voltage across a large one.
Natural and man-made fields
The fair-weather atmospheric field near the ground is about 100 to 150 V/m, directed downward, which means the potential rises by roughly 130 V for each meter of height near the surface. A person standing outdoors does not feel that 130 V from head to feet, because the body is a conductor and distorts the field around it. Under thunderstorms the field at the ground can reach many kilovolts per meter. Under high-voltage transmission lines the field at ground level is typically a few kV/m. Reference levels for public exposure to 50 Hz electric fields in international guidance are in the range of 5 kV/m. These values vary with the standard and its edition, so the original document should be consulted. A converter turns 5 kV/m into 5,000 V/m or 50 V/cm.
Radio waves and power density
For a plane wave in free space, the power density equals the square of the electric field divided by the impedance of free space, about 376.73 ohms. So S = E² / 376.73 in W/m². A field of 1 V/m corresponds to 2.65 mW/m², a field of 10 V/m to 0.265 W/m², and a field of 61.4 V/m to about 10 W/m². This applies to far-field propagating waves and does not hold for static fields or very close to antennas. Transmitter coverage maps and safety assessments use these relations, but the assessments have their own methods and limits, which a unit page cannot replace.
Field strength in decibels
Radio engineering quotes field strength in decibels relative to 1 microvolt per meter, dBµV/m. A field of 1 µV/m is 0 dBµV/m, 1 mV/m is 60 dBµV/m, and 1 V/m is 120 dBµV/m. A test field of 3 V/m is 129.5 dBµV/m. The decibel scale is logarithmic, so doubling the field adds 6 dB and a factor of ten adds 20 dB. Broadcast coverage contours are drawn at stated levels such as 60 dBµV/m. A converter that works on linear V/m values will not read a dB figure, and the dB value must first be turned back into microvolts per meter with 10 raised to the power of the dB value divided by 20.
Immunity testing of electronics
Electromagnetic compatibility standards test equipment by exposing it to a radiated field. IEC 61000-4-3 defines test levels of 1, 3 and 10 V/m, with higher levels such as 30 V/m for harsh environments. A product tested at 3 V/m is exposed to a field of 0.003 kV/m, or 0.03 V/cm. The test field is normally amplitude modulated at 80 percent with a 1 kHz tone, and the frequency range runs from 80 MHz up into the gigahertz range. The standard sets the field, the test layout and the performance criteria. The converter changes only the unit in which the field is expressed, and the test conditions remain those of the standard in force.
Millivolts per meter, kilovolts per meter and neighbors
The site lists conversions between V/m and V/cm, kV/m, kV/cm and mV/m, and the neighboring pairs. One V/m equals 0.01 V/cm, 0.001 kV/m, 0.00001 kV/cm and 1,000 mV/m. A sensor reading of 250 mV/m is 0.25 V/m, and a field of 12 kV/m is 12,000 V/m. A test system showing 0.5 kV/cm shows 50,000 V/m. A mistake that appears often is confusing kV/m with kV/cm, which differ by a factor of 100. Writing the unit in full on the first mention in a report helps readers who work in a different sub-field.
Static, low-frequency and radio-frequency fields
The meaning of a field value depends on frequency. A static or 50 Hz field couples to the body through surface charge, and measurement uses field meters that have to be held away from the observer, who distorts the field. A radio-frequency field couples as an electromagnetic wave and requires calibrated antennas and probes. A quoted 5 V/m could therefore describe a very different exposure at 50 Hz and at 900 MHz. For alternating fields the number may be an RMS value, a peak value or the magnitude averaged over time, and the source has to say which. The conversion between volts per meter and other field units is unaffected.
Relation to voltage and distance
A field in V/m can be turned into a voltage over a path only if the field is known along the path. In a uniform field, V = E x d, so 200 V/m over 0.5 m is 100 V. In a non-uniform field the voltage is the integral of the field along the path, which requires the geometry. A field of 3 MV/m, near the breakdown strength of dry air, over a 1 cm gap corresponds to 30 kV, which is why sparks jump across such a gap at about that voltage under ideal conditions. Humidity, electrode shape and altitude move that threshold, and the number is not a design value.
Notation and reading sources
Write V/m with a capital V, a slash and a lowercase m. The quantity symbol is E, and bold E or an arrow indicates a vector. Many sources give only the magnitude, and the direction is implied by the setup. A figure labeled V/m with no frequency or detector type is incomplete for radio work. Spell out kilovolts per meter when a report might be misread, since kV/m and kV/cm are one letter apart. For comparison across sources, convert everything to V/m first, then check that all values are the same kind, RMS or peak, before drawing conclusions.
Precision and checking
- Keep measured field precision.
- Retain the length denominator.
Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.
Use a working converter
- Electric field strength converter
- Volts per meter to Volts per centimeter converter
- Volts per meter to Kilovolts per meter converter
- Volts per meter to Kilovolts per centimeter converter
- Volts per meter to Millivolts per meter converter
Source and verification scope
The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.