MEASUREMENT & METHODS

Millivolts per meter (mV/m): electric field unit guide

mV/m expresses electric field with millivolts.

Measurement basis

One mV/m corresponds to 0.001 V/m.

Definition conventions

Prefixes use SI decimal powers. The selections remain within the electric-field quantity.

Conversion method

Multiply mV/m by 0.001 for the reference field.

Reference equivalent of mV/m

1 mV/m = approximately 0.001 V/m.

Recorded scale factors: 0.001 for mV/m; 1 for V/m.

Worked example

Known input: 10 mV/m. Reference equivalent: 0.01 V/m. The return conversion gives approximately 10 mV/m.

The calculation preserves a per-meter field quantity.

Common reference values

Input (mV/m)Reference equivalent (V/m)
10.001
50.005
100.01
250.025
500.05
1000.1

Compare one mV/m with other units

Target unitEquivalent of 1 mV/mDefinition guide
Volts per meter (V/m)0.001Read definition
Volts per centimeter (V/cm)0.00001Read definition
Kilovolts per meter (kV/m)0.000001Read definition
Kilovolts per centimeter (kV/cm)1e-8Read definition

Field strength in thousandths of a volt per meter

Electric field strength, written E, is the force per unit charge at a point. Its SI unit is the volt per meter (V/m), which is identical to one newton per coulomb. A millivolt per meter (mV/m) is 0.001 V/m, a scale that fits weak radio signals, atmospheric measurements and sensor specifications. The label contains two letters m. The first is the prefix milli, and the second, after the slash, is the meter, so the full label must be read before any conversion is chosen. A field of 1 mV/m is what would exist across a 1 meter gap with a potential difference of 1 millivolt, if the field were uniform, which gives the unit its physical meaning in everyday terms.

Converting mV/m to V/m, V/cm and kV/m

The site converters cover these relationships. Volts per meter to Millivolts per meter multiplies by 1,000, and Millivolts per meter to Volts per meter by 0.001. Volts per centimeter to Millivolts per meter multiplies by 100,000, because a centimeter is a hundredth of a meter and a volt is 1,000 millivolts. Kilovolts per meter to Millivolts per meter multiplies by 1,000,000, and Kilovolts per centimeter to Millivolts per meter by 100,000,000. In the other direction, Millivolts per meter to Volts per centimeter multiplies by 0.00001, to Kilovolts per meter by 0.000001, and to Kilovolts per centimeter by 1×10⁻⁸. Every factor is a power of ten, so errors usually come from the direction, not the arithmetic.

Field strength examples in mV/m and V/cm

A field of 150 mV/m equals 0.15 V/m. A reading of 500 mV/m is 0.5 V/m, or 0.005 V/cm. In the other direction, 3 V/m is 3,000 mV/m, and 1 V/cm, which equals 100 V/m, is 100,000 mV/m. A dielectric test field of 2 kV/m corresponds to 2,000,000 mV/m, and 1 kV/cm is 100,000,000 mV/m. Dry air at ordinary pressure breaks down only near 3 MV/m (about 30 kV/cm), far above any of these figures. Checking is simple: the millivolt per meter number must be larger than the same field in V/m by a thousand, and smaller numbers should accompany larger units like kV/m.

Broadcast and radio field strength

Radio engineers describe received signal strength as a field strength, often in decibels relative to 1 µV/m. A level of 0 dBµV/m equals 1 µV/m, or 0.001 mV/m, and each 20 dB multiplies the field by ten, so 40 dBµV/m is 100 µV/m or 0.1 mV/m, and 60 dBµV/m is 1 mV/m. Coverage specifications for broadcasting and navigation systems state minimum usable field strengths at this scale, which can be far smaller than a volt per meter. The decibel form converts to mV/m by taking the antilog: 54 dBµV/m corresponds to about 0.5 mV/m. Radio astronomers and long-wave stations also work in this range, where the signal competes with atmospheric noise.

Natural and environmental fields

The Earth carries a fair-weather electric field at the ground that averages roughly 100 to 130 V/m, which is 100,000 to 130,000 mV/m. During thunderstorms the local field can swing by orders of magnitude and reverse sign. Sferics, the radio emissions of lightning, are measured in mV/m at distance. Biological tissues respond to much weaker internal fields: electric fields in the body from external sources fall far below the external value, because tissue is conductive and screens the interior. Weak ambient fields in the tens of mV/m range are encountered under overhead power lines at large distances, and values depend heavily on voltage, geometry and height above ground.

Exposure limits and immunity tests

Standards quote field strength in V/m, so mV/m figures are usually converted first. ICNIRP reference levels for the general public in the 1998 guidelines are around 41 V/m near 900 MHz, which is 41,000 mV/m. Product immunity testing under IEC 61000-4-3 applies radiated fields of 1, 3, 10 or 30 V/m, equal to 1,000, 3,000, 10,000 or 30,000 mV/m. A field of a few hundred mV/m, by comparison, is below these levels by a factor of ten or more. These reference values are published by the named bodies and are given here only for scale. A conversion does not show whether a measurement complies with a given standard.

Measuring weak fields

Antennas and field probes convert field strength into a voltage using an antenna factor, in dB per meter, so the receiver reading must be adjusted before the result is stated in mV/m. Calibrated probes in a screened room can resolve down to roughly the mV/m range, but ambient interference often sets the floor. Probes respond to the component along their axis, and a three-axis probe sums the components. Readings at a few frequencies are not comparable unless the bandwidth and detector type, such as peak or RMS, are given. Because fields near antennas change quickly with distance, a position error of a few centimeters can change the result significantly.

Electric field versus other field quantities

The label mV/m names the electric field. Magnetic field strength, written H, is measured in amperes per meter, and flux density B in teslas. In a free-space radio wave the ratio of E to H is about 377 ohms, so an electric field of 377 mV/m would be accompanied by a magnetic field of about 1 mA/m, but the relation applies only in the far field, not close to an antenna or in a static case. Power density combines them: an electric field E in a plane wave carries E squared divided by 377 watts per square meter, so 1 V/m gives about 2.65 mW/m². The conversion on this page converts only units of electric field.

Reading the label correctly

Case and position matter in mV/m. The lowercase m before V is milli, the capital V is volt, and the m after the slash is meter. MV/m with a capital M would be megavolts per meter, a factor of 10⁹ larger, which is the scale of accelerator cavity fields. Writing mV/m for a value that is actually mV/cm drops a factor of 100, so keep the denominator exactly as the source shows it. A source that gives dBµV/m is not in the same unit as mV/m until converted. Copy the symbol with its case and denominator intact when moving a value between documents.

Precision and checking

  • Keep measured field resolution.
  • Retain lowercase m on V.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →