Pulses compared with a battery label
The label of a small battery gives capacity in milliampere-hours. The datasheet of a wireless sensor lists the charge of one measurement or one transmission in nanocoulombs or microcoulombs. To estimate how many pulses a cell can deliver, both must be in the same unit. This page multiplies the nanocoulomb value by about 2.77778e-10 and returns milliampere-hours, so a 10 nC pulse reads as about 2.78e-9 mAh. The result is minute, and that is the point: it tells you that single events hardly use the cell, and only their repetition matters. The page helps makers of sensor nodes, students working on unit exercises and anyone who must reconcile a charge budget with a printed capacity.
How 3.6 coulombs make a milliampere-hour
A milliampere-hour is one thousandth of an ampere flowing for 3,600 seconds, so 1 mAh = 3.6 C. A nanocoulomb is 10^-9 C, so 1 nC is 10^-9 / 3.6 mAh, which is about 2.7778 × 10^-10 mAh. The BIPM SI Brochure defines the coulomb as an ampere-second and accepts the hour for use with the SI. The page applies this chain through its base unit. A fast check is to remember that 1 mAh holds 3.6 billion nanocoulombs, so a pulse in nanocoulombs is divided by 3.6 × 10^9 to get milliampere-hours.
Ten nanocoulombs in milliampere-hours
The default of 10 nC returns about 2.7778e-9 mAh. A pulse of 1,000 nC, or 1 µC, is about 2.7778e-7 mAh, and 45,000 nC is about 1.25e-5 mAh. In reverse, 1 mAh equals 3,600,000,000 nC, and 220 mAh equals 7.92 × 10^11 nC. The exponents are the useful part: for a pulse in the thousands of nanocoulombs, the result has an exponent of about minus seven or smaller. A result near 1 mAh for a nanocoulomb input means the page was set to the wrong unit pair.
A radio burst over a year
Take an illustrative wireless sensor that transmits for 3 ms at 15 mA each time. The charge is 15 mA × 3 ms = 45 µC, which is 45,000 nC, or about 1.25e-5 mAh. If it reports every 5 minutes, that is 288 transmissions a day, so 0.0036 mAh a day and about 1.31 mAh in a year. A 220 mAh coin cell would then spend under 1 percent of its capacity on the radio bursts, and other drains such as sleep current, the sensor and self-discharge matter more. The figures are made-up round numbers to show the method, and the actual consumption depends on the device and its firmware.
Sleep current as charge
Charge accumulates continuously, even when nothing happens. A sleep current of 1 µA over a day moves 86,400 × 10^-6 C, which is 0.0864 C or 86,400,000 nC. In milliampere-hours that is 0.024 mAh a day, about 8.8 mAh a year, which is four percent of a 220 mAh cell. Comparing this with the radio bursts above shows that the quiet periods cost several times more than the transmissions, and that reducing sleep current by a factor of two saves more than reducing the burst length by a tenth. The page turns each term into the unit of the battery label, so the terms can be added and compared.
Coulomb counting in fuel gauges
Battery fuel gauge chips estimate remaining charge by integrating current over time and storing the total in small steps. The step size is often listed in microcoulombs or nanocoulombs per count, and the host software reports the result in milliampere-hours. A gauge that counts in steps of 1,000 nC adds about 2.78e-7 mAh per count, so a drain of 100 mAh needs about 360 million counts. These numbers show why the chips use wide counters, and they help when you read a register map that lists a charge per count. The values are illustrative and the data sheet of your gauge lists the real resolution. A USB power meter that shows accumulated charge while a phone charges is another everyday case. If it reads 1,500 mAh, the charge that passed is 5,400 C, which is 5.4 × 10^12 nC. The meter integrates current at the USB voltage, which differs from the voltage of the cell inside the phone, so its figure does not equal the charge added to the battery.
From milliampere-hours back to nanocoulombs
To go the other way, select milliampere-hours as the source and nanocoulombs as the target. A value of 2 mAh equals 7.2 × 10^9 nC, and 0.5 mAh equals 1.8 × 10^9 nC. Multiply by 3,600,000,000. The result is a very large number, so exponent form is easiest to copy. This direction is useful when a battery capacity needs to be compared with pulse charges listed in a datasheet, and you want to know how many pulses fit into the capacity, found by dividing the capacity in nanocoulombs by the charge per pulse.
Ideal capacity versus delivered capacity
The rated milliampere-hours of a cell are measured under specified conditions, such as a stated discharge current and end voltage. A cell asked for short, strong pulses delivers less than the label, because internal resistance drops the voltage during each pulse, and cold weather reduces the figure further. The conversion here treats charge as charge, and it cannot know how much of it the cell will release at a given load. Use the converted numbers as the demand side of an estimate and the discharge curves in the cell datasheet for the supply side. Pulse loads need extra attention with coin cells, whose internal resistance can be tens of ohms. A 15 mA burst through 20 ohms drops 0.3 V, so a cell that reads 3.0 V at rest sags to 2.7 V during the burst, and a processor with a brownout level near 2.7 V may reset while the cell still holds most of its charge. Designers add a capacitor of a few hundred microfarads to carry the pulse, so that the cell supplies a smaller and steadier current.
Turning a charge into battery life
The page converts the unit of a charge. It does not estimate battery life, select a cell or check safety. A real estimate needs the average current, temperature, self-discharge, the cutoff voltage of the electronics and a margin. Use the converter for consistent units and the datasheets for the behavior of the parts. Keep the unit symbol mAh next to every converted number, because a bare figure could be read as mA, the unit of current, and the difference between a charge and a current is the most common source of confusion in battery budgets.