Putting viscosity into SI formulas

Fluid formulas written in SI units expect viscosity in pascal-seconds, the same as kilograms per meter per second. Product data sheets for coolants, oils, inks and syrups quote it in millipascal-seconds or centipoise. Before the number goes into a Reynolds number, a pressure-drop formula or a pump calculation, it has to be converted. This page divides the millipascal-second value by 1,000 and gives pascal-seconds, so 85 mPa·s becomes 0.085 Pa·s. Skipping the step produces an error of a factor of 1,000 in the result, which is large enough to flip a flow from laminar to turbulent in a calculation and send the design in the wrong direction.

The exact factor

Milli means one thousandth, so 1 mPa·s is 0.001 Pa·s, and 1,000 mPa·s make 1 Pa·s. The pascal-second is the coherent SI unit of dynamic viscosity, and the prefix rules are listed in the BIPM SI Brochure and in NIST SP 811. The factor is exact. The default of 10 mPa·s gives 0.01 Pa·s, and 1.002 mPa·s, a value for water at 20 degrees Celsius, gives 0.001002 Pa·s. A mixer spec of 850 mPa·s reads 0.85 Pa·s in SI form. To check a result, multiply by 1,000 and compare with the number you started with. Any difference beyond rounding means a digit was mistyped.

A Reynolds number for a water pipe

The Reynolds number is Re = ρ × v × D / μ, with density ρ in kg/m³, speed v in m/s, diameter D in meters and dynamic viscosity μ in Pa·s. For water at 20 degrees Celsius, with ρ of about 998 kg/m³, a speed of 1 m/s in a 25 mm pipe and a viscosity of 1.002 mPa·s, which is 0.001002 Pa·s, the result is 998 × 1 × 0.025 / 0.001002, about 24,900. That is turbulent flow. Entering the viscosity as 1.002 instead of 0.001002 would give a Reynolds number of 24.9, a laminar result and a completely different design. The page supplies the converted viscosity for the formula.

Thick fluids and the laminar regime

Syrups, glycerol and heavy oils flow in the laminar regime at ordinary speeds, which makes the unit step matter even more. Glycerol near 20 degrees Celsius has a viscosity of roughly 1,400 mPa·s, which the page turns into 1.4 Pa·s. Pushing it at 0.5 m/s through a 20 mm pipe with a density of about 1,260 kg/m³ gives a Reynolds number of 1,260 × 0.5 × 0.02 / 1.4, about 9. The flow is strongly laminar, and the pressure drop follows the Hagen-Poiseuille relation, which is proportional to viscosity. A thicker fluid therefore needs a proportionally larger pressure for the same flow, which is why heated lines and larger pumps appear in plants that move syrups and resins.

Values you may meet on a data sheet

Typical ranges help to judge a number. Water is about 1 mPa·s at 20 degrees Celsius, whole milk a little above 2, olive oil in the range of 80 mPa·s, and many honeys several thousand. Air is only about 0.018 mPa·s. These are approximate and depend on temperature, so use them only as a sanity check. If a data sheet for engine oil lists 100 mPa·s, the page gives 0.1 Pa·s, and a value of 100,000 mPa·s for a paste gives 100 Pa·s. A check against these orders of magnitude finds most typing errors before they reach a calculation. For a kitchen or food-lab example, a sauce listed at 3,000 mPa·s is 3 Pa·s, and the value tells you it will flow slowly in a pipe, so a positive-displacement pump is a more natural fit than a centrifugal one.

Converting pascal-seconds back to millipascal-seconds

Select pascal-seconds as the source and millipascal-seconds as the target to multiply by 1,000. A viscosity of 0.0008 Pa·s gives 0.8 mPa·s, close to water at 30 degrees Celsius, and 2.5 Pa·s gives 2,500 mPa·s. Use this direction when a simulation or a textbook table gives SI values and your viscometer reads in mPa·s or centipoise. Round the result to the digits that the instrument supports, usually two or three, and note the temperature with the number, for example 0.8 mPa·s at 30 degrees Celsius for water. A viscometer reading is valid only at the temperature and shear rate of the test.

Shear rate and non-Newtonian fluids

A single viscosity figure describes a Newtonian fluid, such as water or mineral oil, whose viscosity does not depend on how fast it is sheared. Paints, ketchup, blood and polymer melts are non-Newtonian, and their apparent viscosity depends on shear rate. A data sheet may therefore give a value at a stated spindle speed or shear rate. Converting that number from mPa·s to Pa·s keeps the figure valid for the same condition, but using it in a formula for another flow rate can mislead. A paint listed at 400 mPa·s at one speed, or 0.4 Pa·s, may read 150 mPa·s at a higher speed, and the lower figure is the one that governs brushing or spraying. Look for a flow curve or at least two readings at different speeds before sizing equipment for such fluids.

Units that look similar

Pa·s, N·s/m² and kg/(m·s) are the same unit written three ways, and the page uses Pa·s. The older cgs unit, the poise, is 0.1 Pa·s, and the centipoise is one millipascal-second. Kinematic viscosity is a different quantity, in m²/s or centistokes, and needs a density to become dynamic viscosity. Mixing these up leads to errors of a factor of 10, 1,000 or the density, and the symbols are close enough to cause slips. Write the full unit next to each viscosity and check that the quantity in the formula is dynamic viscosity before entering the number.

Fluid behavior the factor cannot supply

The page converts one unit of dynamic viscosity to another. It does not look up viscosity for a substance, correct for temperature or shear rate, compute a Reynolds number or pressure drop, or choose a pump. Those steps need the density, the geometry and the operating conditions. Use the converted figure in the correct formula and take the fluid data from your supplier or a measurement at the actual working temperature.