Skin sensors and other low-level conductance readings

Electrodermal activity sensors, used in biofeedback and sleep or stress research, report skin conductance in microsiemens, with values of a few µS being common. The electronics behind them, such as the front-end of a data acquisition board, may list resolution or noise in nanosiemens. A researcher who needs to say that a board resolves 20 nS on a signal of 4 µS has to put both figures in one unit. This page divides the nanosiemens value by 1,000 and returns the microsiemens figure. It also suits hobbyists who build probes, students in a lab course, and technicians who read meters with different ranges and want a consistent column in a log. In a report, a line such as noise 20 nS (0.02 µS) against a signal of 4 µS makes the ratio of 200 to 1 obvious.

Dividing by 1,000

Nano is 10^-9 and micro is 10^-6, so one microsiemens equals 1,000 nanosiemens. The formula is µS = nS × 0.001. The prefix definitions come from the BIPM SI Brochure and NIST SP 811, and the factor is exact. By hand, move the decimal point three places to the left. 2,500 nS becomes 2.5 µS, 750 nS becomes 0.75 µS and 45,000 nS becomes 45 µS. Because the shift is only three places, the result is easy to confirm by eye, and the page is mostly a guard against slips when many values pass through a spreadsheet. Going the other way multiplies by 1,000, so 0.5 µS is 500 nS and 12 µS is 12,000 nS.

A probe that reads 18,000 nS dry and 62,000 nS humid

The page opens with 10 nS and gives 0.01 µS. The decimal is short enough to read directly, yet it still shows why keeping fractional microsiemens matters. A rounded answer of 0 µS would suggest no conductance at all, though 10 nS is a real, measurable value in an insulation test. A reading of 750 nS is 0.75 µS and a reading of 2,500 nS is 2.5 µS. A sensor that reports 45,000 nS is at 45 µS, a larger conductance that would draw a clearly measurable current at a few volts. Keep two or three decimals in the µS column of a log so that the smallest readings do not disappear. A bench check might go like this: a probe shows 18,000 nS in dry air and 62,000 nS after a humid hour. In microsiemens those are 18 and 62, so the change is 44 µS, a figure easier to enter in a notebook than a difference of nanosiemens.

Conductance is not the same as conductivity

Handheld water meters used for aquariums, hydroponics and drinking-water checks report conductivity in microsiemens per centimeter, written µS/cm. That unit describes a property of the liquid and includes a length. The conversion on this page concerns conductance in siemens, a property of a particular sample or component, with no length in the unit. A reading of 500 µS/cm cannot be entered here as 500 µS and then used as a conductance of a cell. If you have a conductivity reading, keep its per-length unit through your work. This page applies when the quantity really is a conductance, such as the value measured between two electrodes at a fixed geometry.

From conductance to resistance

Resistance is the reciprocal of conductance, and the numbers are easy once the units are in microsiemens. One microsiemens is 1 MΩ. A reading of 2.5 µS corresponds to 400,000 Ω, which is 400 kΩ, and a reading of 0.01 µS, the default result, corresponds to 100 MΩ. If a multimeter offers a conductance range, it can resolve resistances that its ohm range cannot, because the display shows the reciprocal with useful digits. The page will not take the reciprocal for you. Convert nS to µS first, then divide one by the conductance in siemens or work in megohms using the one-to-one relation. For a meter that reads 0.35 µS, the resistance is about 2.86 MΩ, which you can confirm by entering 350 nS on this page and taking the reciprocal of the result.

Combining several parallel paths

Conductances in parallel add directly, which is the main reason people prefer them to resistances in some calculations. Three leakage paths of 250 nS, 750 nS and 2,000 nS together give 3,000 nS, which the page converts to 3 µS. Adding in nanosiemens and converting at the end avoids rounding in the middle. In series, the reciprocals add, so conductances do not simply sum. Be sure that the circuit is really a parallel arrangement before adding. The converter does not check the topology and does not know whether your paths interact, so it is a unit tool and not a circuit model. Mixed ranges are common as well. A reading of 1.2 µS added to 900 nS needs one unit before summing: 900 nS is 0.9 µS, so the total is 2.1 µS.

mho, siemens and the symbol µ

The siemens is the SI unit of conductance, equal to one ampere per volt. Older literature calls the same unit the mho, which is ohm spelled backward, and some meter dials show an inverted omega symbol for it. The prefix micro uses the Greek letter µ. Text systems that cannot show it sometimes print u, so uS in a plain file means microsiemens. Confusing the lowercase µ with a lowercase m, which is milli, changes the value by a factor of 1,000. Check a printed column with a value you can verify, and keep the full unit name in the header of any table you share with other people.

Resolution and what the digits mean

Dividing by 1,000 does not add precision. A conductance read as 750 nS on a meter with a resolution of 10 nS is known to about two digits, so 0.75 µS is the sensible figure and 0.7500000 µS suggests precision that does not exist. The page shows up to twelve significant digits, which is a limit of the display and not a claim about the measurement. If the display flickers between 740 nS and 760 nS, the honest figure is 0.75 µS with an uncertainty of about 0.01 µS. Report the result with the resolution of the instrument, and mention conditions that shift conductance readings, such as temperature and electrode contact. The converter restates a value in another unit and does not check equipment limits, safety, material behavior or compliance with any rule.