Picowatts belong to measurement, BTU/h to buildings
A picowatt is one trillionth of a watt. Optical power meters, photodiodes and radio receivers often work down in this range, because the signals they detect are faint. A BTU per hour is the language of furnaces and air conditioners. A person who needs both usually works in instrumentation inside a building, for example judging whether a heat leak from equipment could disturb a sensitive detector, or reading an American specification of heat dissipation that has to be compared with a detector noise floor quoted in watts. The default, 10 BTU/h, converts to 2,930,710,701,722.222 pW, close to 2.93 trillion picowatts, which is just 2.93 W written in a very small unit.
The multiplier step by step
One International-table BTU equals 1,055.05585262 J, so one BTU per hour is 1,055.05585262 divided by 3,600, or 0.29307107017222 W. The prefix pico is 10^-12, so a watt equals 10^12 pW. The product is 293,071,070,172.22 pW per BTU/h, which the formula on this page rounds to 293,071,070,172. Going back, one picowatt is 3.4121e-12 BTU/h. The source for the BTU definition is NIST SP 811 and the prefix table is in the BIPM SI Brochure. The factor is exact in principle, and the converter returns the product in double-precision floating point, so you may see digits beyond the twelfth that mean nothing physically.
Fractions of a BTU per hour
Instrument-scale heat flows are minute in BTU terms. A flow of 0.000001 BTU/h, one millionth, is 293,071.07 pW, which is 0.29 microwatts. A flow of 2.5 BTU/h is 7.3268e11 pW, about 0.73 W, the order of a small LED lamp. The first of these is the kind of power that a sensitive meter could resolve with averaging in a quiet lab. The point of the comparison is to show how much range a single unit chain can cover without rewriting constants. All of these figures come from the same multiplier, applied to different inputs.
Converting a detector figure into BTU per hour
Reverse the menus for a figure from a datasheet. A light level of 50 pW, which is in the range of a weak signal reaching a photodiode, corresponds to 1.7061e-10 BTU/h. One picowatt alone is 3.4121e-12 BTU/h. These values are so small that a heating or cooling load calculation would never include them. The reason to compute them is to check scale. If a thermal analysis shows a stray heat load of 0.001 BTU/h on a detector housing, the page tells you that is 293 million picowatts, which dwarfs a 50 pW signal by a factor of about six million. That comparison motivates thermal isolation and shielding, and shows why signal power and heat load must be considered together.
Pico, nano and femto mix-ups for BTU/h
The step from nano to pico is a factor of 1,000, and a slip of one prefix is the most common error. Here 1 BTU/h is 293,071,070,172 pW or 293,071,070.172 nW. Both numbers look similar to a quick reader, so write the unit next to the value every time. Pico is 10^-12, femto 10^-15, and nano 10^-9. The symbol is pW, with lowercase p and capital W. Capital P would mean peta, a thousand trillion, which would make an error of 27 orders of magnitude. In plain text the letter p alone often means pico in electronics, but P alone should not be used for it.
Power versus energy at this scale
Because pW is a rate, the energy delivered depends on how long the flow lasts. A source delivering 50 pW for one hour supplies 180 nanojoules, since 50e-12 W times 3,600 s equals 1.8e-7 J. Detectors integrate over time to build up a measurable signal, so the useful quantity is often energy collected rather than power. BTU per hour is also a rate, and the matching energy unit is the BTU. If you mix the two, for example by comparing a power in pW with an energy in BTU, no unit conversion can repair the comparison. State a duration first, convert the rate to energy, and then compare like with like.
Rounding in a chain of conversions
When you report a result near the noise floor of a measurement, the uncertainty of the instrument usually dominates the uncertainty of the conversion. The factor 293,071,070,172 is accurate to better than a part in a billion for the International-table BTU, so keep the instrument significant digits, such as 2.9e11 pW from a two-digit input. Avoid converting through intermediate units such as microwatts and rounding each step. If you have a result in nanowatts from another page, go back to the original BTU/h value rather than multiplying the nanowatt answer by 1,000, because small rounding errors multiply along with the number.
Wireless signal levels in picowatts
Radio receivers in routers, phones and Bluetooth devices report signal strength in dBm, and the power behind a weak reading is in the picowatt range. A level of -90 dBm is 1 pW, and -73 dBm is 50 pW, since each 10 dB step is a factor of ten. A network technician comparing a router datasheet in dBm with a thermal specification in BTU/h can put both in watts first. One picowatt is 3.4121e-12 BTU/h, so even a strong radio signal at that level adds no measurable heat, and the heat that a router case sheds, a few BTU/h, is many orders larger than the signal it handles. When you log signal levels for a site survey, record the dBm reading and the converted watts side by side so a later reader can check the step.
The full range from a window air conditioner
To see the whole span of the unit chain, take a one-ton air conditioner, rated at 12,000 BTU/h of cooling. The page returns 3.5168e15 pW, the same as 3,516.85 W. Compare that with a 50 pW optical signal and the ratio is about seventy trillion to one. A converter that handles both ends accepts the same multiplier, so the only care needed is in reading exponents and keeping prefixes straight. The ton here is the refrigeration ton, defined as 12,000 BTU/h, not a unit of weight. Because the multiplier is applied identically to every input, the result for a sum of loads equals the sum of the converted results, which helps when you total several small heat sources. Because the largest term dominates any such sum, a single warm component usually decides the result, and the picowatt-scale terms only matter when everything else has been removed or cooled.