What viscosity measures
Viscosity is a fluid's resistance to flowing. Honey is more viscous than water, and cold oil flows more slowly than warm oil. In a simple shear flow, a layer of fluid is dragged over another, and the force per unit area needed to maintain that motion, the shear stress, grows with the rate at which layers slide past each other, the shear rate. Dynamic viscosity is the ratio between the two. This page takes a shear stress and a shear rate from a measurement or a problem statement and returns the viscosity in Pa·s. It is the starting point for flow in pipes, lubrication films and mixing.
Newton's law of viscosity
For a Newtonian fluid, shear stress is proportional to shear rate: τ = μ × γ̇. Solving for the viscosity gives μ = τ / γ̇, which is what the page computes. Shear stress is in pascals, shear rate is in reciprocal seconds, and the quotient has the unit Pa·s, equal to kg/(m·s). A fluid is Newtonian if this ratio stays constant as the shear rate changes. Water, air, mineral oils and many simple liquids behave this way over wide ranges. Paints, ketchup, blood and polymer solutions do not, and their ratio depends on how fast they are sheared.
Shear stress of 2 Pa at 100 per second
The default entry is a shear stress of 2 Pa and a shear rate of 100 per second. Dividing gives 0.02 Pa·s, which is 20 mPa·s or 20 centipoise. That is about twenty times the viscosity of water and similar to a light oil or a thin syrup. The example illustrates the proportions: for the same stress, a thicker fluid shears more slowly, so a lower shear rate for the same stress means a higher viscosity. The reverse also holds, and doubling the stress for the same rate doubles the viscosity.
Water and thicker liquids
Water at 20 °C has a dynamic viscosity of about 1.0 mPa·s, or 0.001 Pa·s. A shear stress of 0.1 Pa producing a shear rate of 100 per second matches that value. Thicker liquids need more stress: 50 Pa at a shear rate of 10 per second gives 5 Pa·s, an illustrative number in the range of honey at room temperature, while glycerol at 20 °C is around 1.4 Pa·s. A stress of 12 Pa at 60 per second gives 0.2 Pa·s, comparable to a cool engine oil. Air, by contrast, is about 1.8 × 10⁻⁵ Pa·s, tens of thousands of times less viscous than water.
Units: pascal seconds, poise and centipoise
The SI unit is the pascal second. The older CGS unit is the poise, where 1 P = 0.1 Pa·s, and the centipoise, which equals exactly one millipascal second, remains common in industry. Water near 20 °C is about 1 cP, which makes the centipoise a handy anchor. Kinematic viscosity is a different quantity: dynamic viscosity divided by density, in m²/s, with the stokes and centistokes as CGS units. A report that says a fluid has a viscosity of 50 without a unit can be off by a factor of 1,000, so always check whether a value is dynamic or kinematic and which unit it uses.
Getting stress and rate from a measurement
A rotational viscometer shears a fluid between a spinning surface and a stationary one, and the instrument reports torque and rotational speed, which convert to stress and rate based on its geometry. For parallel plates, shear rate equals the plate speed divided by the gap, and shear stress equals the force divided by the plate area. A plate of 0.01 m² dragged with 0.2 N has a stress of 20 Pa. If the top plate moves at 0.05 m/s over a 1 mm gap, the rate is 50 per second, and the page gives 0.4 Pa·s. Geometry mistakes are the largest source of error here.
Temperature and Newtonian assumptions
Viscosity depends strongly on temperature. Liquids thin as they warm: water drops from about 1.8 mPa·s at 0 °C to 0.28 mPa·s at 100 °C, and an oil can change by a factor of ten over a modest range. Gases do the opposite, becoming slightly more viscous when heated. Always note the temperature of a measurement alongside the result. The page also assumes a Newtonian fluid. For a shear-thinning material, repeating the calculation at different shear rates will give different values, which is a sign that the single number is only an apparent viscosity.
Using the result in flow calculations
Once you have the viscosity, you can estimate flow behavior. Poiseuille's law gives the flow of a viscous liquid through a narrow tube, and the Reynolds number compares inertial to viscous forces to indicate whether flow is smooth or turbulent. In both, viscosity appears in the denominator or as part of a ratio, so an error in the viscosity carries directly into the flow estimate. In lubrication, the viscosity sets the load a thin oil film can carry and the friction it adds, which is why engine oils are graded by viscosity at both cold-start and operating temperatures. In food and cosmetics, a target viscosity controls how a sauce pours or a lotion spreads. In medicine, blood plasma and whole blood have different viscosities, and the viscosity of the fluid in a syringe affects the force needed to inject it. Quality control labs often measure viscosity at a fixed temperature and shear rate so that batches compare fairly, and the stated conditions matter as much as the number. A paint that reads 0.5 Pa·s at 25 °C and one that reads 0.5 Pa·s at 40 °C are not equivalent. Record the temperature, the instrument and the shear rate with the result. A fluid ten times more viscous needs ten times the pressure difference to flow through the same tube at the same rate under laminar conditions.
Newtonian fluids in simple shear only
The calculation is a scalar educational model for a Newtonian fluid in simple shear. It does not handle non-Newtonian fluids, turbulent or viscoelastic behavior, temperature variation along the sample, or wall slip. It makes no assertion about instrument calibration or safety. For design work with real fluids, use measured viscosity curves or supplier data at the relevant temperatures and shear rates.