From heat statistics to the power bill
Fuel and heat are tallied in joules and their multiples, while electricity is sold in kilowatt-hours. When an energy agency reports that a plant consumed so many terajoules of fuel, or that a region used a given number of terajoules of electricity, a reader who thinks in kWh needs a bridge. This page converts a terajoule value to kilowatt-hours by multiplying by 10^12 and dividing by 3.6 million. Enter the TJ figure and keep kilowatt-hours as the target. National electricity reports use TWh, and one TWh is 3,600 TJ, so a country that consumes 250 TWh in a year has used 900,000 TJ. The result is a plain count of kWh that can be compared with a bill, a battery rating or a generation report.
Dividing by 3.6 million joules
A kilowatt-hour is one kilowatt acting for 3,600 seconds, which is 3,600,000 J. So kWh = TJ × 10^12 ÷ 3,600,000, which equals TJ × 277,777.78. The 3,600 is a count of seconds in an hour, so the factor is exact. The kilowatt-hour is not an SI unit, but it is accepted for use with it, and NIST SP 811 gives its joule value. By hand, divide the TJ figure by 0.0036 or multiply by 277,778: 0.5 TJ is 138,889 kWh. Going the other way, kWh times 0.0000036 gives TJ, so 100,000 kWh is 0.36 TJ. For a rough check, remember that 1 GWh is 3.6 TJ, so 36 TJ is 10 GWh.
Ten terajoules as 2.78 gigawatt-hours
The page opens with 10 TJ and returns about 2,777,777.78 kWh, which is 2.78 GWh. A household that uses 10,000 kWh a year, an illustrative figure close to many national averages, would take 278 years to use that much, so the default equals the yearly use of 278 such households. A wind turbine rated at 3 MW running at a capacity factor of 35 percent produces about 9,198 MWh a year, so the default is roughly the output of a third of a year from one such turbine. These comparisons are for scale only, and real output varies by site.
Battery packs and charging
A battery rated at 60 kWh holds 216 MJ, which is 0.000216 TJ. One terajoule is thus the capacity of about 4,630 such packs. A home battery of 13.5 kWh stores 48.6 MJ. Rated capacity is not the same as usable capacity, since packs reserve a margin and lose energy in charging. The converter treats the rating as an energy and does not account for losses. When comparing a vehicle pack with a fuel total in terajoules, include the efficiency of the drivetrain separately, because an electric motor and an engine turn stored energy into motion with different efficiencies. At the other end of the scale, a 15 Wh phone battery holds 54,000 J, so 1 TJ equals about 18.5 million full charges.
Power plants and capacity factor
A 100 MW plant at full output for one hour delivers 100 MWh, which is 360 GJ or 0.36 TJ. Running for 10 hours, it delivers 3.6 TJ. Capacity factor, the share of the year at full output, turns a rating into annual energy: 100 MW at 40 percent for 8,760 hours gives 350,400 MWh, or about 1,261 TJ. This page performs the unit step. The load profile, outages and efficiency stay with the data source. When statistics list fuel input in terajoules and electricity output in kilowatt-hours, the ratio between the two converted figures gives the plant efficiency. Reading a log in reverse works too: 1,261 TJ of annual output corresponds to about 350 GWh.
Thermal input versus electrical output
A power plant that burns 10 TJ of fuel has used 2,777,778 kWh of heat energy, but it does not deliver that much electricity. If the electrical efficiency is 40 percent, the output is about 1,111,111 kWh. Statistics offices therefore report primary energy and final electricity separately. Using the page on both sides of the plant makes the loss visible: convert the fuel input and the metered output into the same unit and compare them. Combined heat and power plants return some of the rest as useful heat, which this page cannot model.
Gasoline and electricity side by side
The US Environmental Protection Agency counts a gallon of gasoline as 33.7 kWh of energy content, which is 121.3 MJ. At that value, 1 TJ is about 8,244 gallons of gasoline, and 277,778 kWh. Comparing the energy content of fuel with electricity from a plug is useful, but vehicles use energy at different efficiencies, so an electric car covers more distance per kWh of electricity than a gasoline car per kWh of fuel. Distance per energy is a vehicle property and does not come from this page.
Kilowatt-hours against kilowatts
A kilowatt measures power, and a kilowatt-hour measures energy. A 2 kW heater running for 3 hours uses 6 kWh, which is 21.6 MJ. A bill states kWh, and a nameplate states kW, so confusing them changes the answer by the number of hours. An electric vehicle charger rated at 11 kW fills a 60 kWh pack in about 5.5 hours at best, and the energy delivered, not the rating, is what the meter bills. When a report gives an annual terajoule figure and you want the average power, divide the kWh by 8,760 hours to get kW: 10 TJ per year is 2,777,778 kWh and an average of about 317 kW. The converter gives the energy figure, and the division is a separate step. A refrigerator that averages 50 W uses 438 kWh in a year, which is about 1,577 MJ.
Reporting grid-scale numbers
Large energy figures read better in GWh or TWh than in kilowatt-hours, so 2,777,778 kWh is normally written as 2.78 GWh. Keep the digits to the precision of the source and state the period, since a total without a year or a month is hard to compare. If two reports disagree after conversion, look at whether one uses gross and the other net values, and whether one counts heat while the other counts electricity. The factor of 3.6 million is fixed, so the usual cause is a difference in what was measured. For quick checks, 36 TJ is 10 GWh and 360 TJ is 100 GWh. Sales and tariff documents sometimes quote MWh, so 1 MWh is 3.6 GJ and 10 TJ is 2,778 MWh.