MEASUREMENT & METHODS

Energy: units and measurement guide

Use energy units to express a known quantity transferred as work or heat.

Measurement basis

Energy can be transferred through work or heat. Rescaling a known energy amount does not identify which physical process produced it.

Definition conventions

Calories use the thermochemical convention, BTU uses the International Table definition and foot-pounds mean foot-pounds force.

Conversion method

Use the recorded energy-factor ratio and retain any named calorie or BTU convention.

Choose the conversion direction

Confirm the source energy unit, including its definition, before choosing the target.

The joule and its many relatives

Energy is the capacity to do work, and the SI unit is the joule (J), the energy transferred when a force of one newton acts through one meter. The same unit equals one watt second, so 1 kWh is 3.6 MJ. The joule is named after James Prescott Joule, who established the mechanical equivalent of heat in the 1840s. Because energy appears in mechanics, heat, electricity, chemistry and nuclear physics, many other units remain in use: the kilowatt hour on utility bills, the calorie in nutrition, the British thermal unit in heating, the electronvolt in atomic physics and the foot pound-force in US engineering. The page supports 17 of them, and every conversion reduces to a fixed factor against the joule.

Kilowatt hours and electricity bills

Electric utilities sell energy in kilowatt hours. One kWh is the energy used by a 1 kW load running for an hour, equal to 3,600,000 J, 3.6 MJ or 1,000 Wh. A 60 W lamp left on for 5 hours uses 300 Wh, which is 0.3 kWh or 1.08 MJ. The unit is written kWh, and kW/h is wrong, since that would be a power per time. The kilowatt hour is accepted in practice though not an SI unit. A household using 900 kWh in a month consumed 3.24 GJ. Seeing the figure in joules shows how small a joule is and why consumer energy is quoted in larger units.

Calories and the food Calorie

The thermochemical calorie is defined as exactly 4.184 J, and the kilocalorie is 4,184 J. Nutrition labels in the United States use the Calorie, written with a capital C, which equals a kilocalorie. Europe lists both kcal and kJ. A 2,000 kcal day is 8,368 kJ, or 8.368 MJ, which is 2.324 kWh. An apple of about 95 kcal supplies roughly 400 kJ. Other calories exist: the International Table calorie is 4.1868 J, and the 15 °C calorie is about 4.1855 J, so the difference between versions is under 0.1 percent for the common ones and rarely matters on food labels. The page uses the thermochemical value, 4.184 J. A convenient check is that 1 kcal is 4.184 kJ, so a 250 kcal snack is 1,046 kJ and 0.29 kWh.

British thermal units and therms

The British thermal unit is the heat unit of US heating and air conditioning. The International Table BTU is 1,055.05585262 J, about 1,055 J, and the thermochemical BTU is 1,054.35 J, a small difference. One kWh equals 3,412.14 BTU, a factor used when comparing electric heaters with gas furnaces rated in BTU per hour. A furnace rated 80,000 BTU/h is about 23.4 kW. A therm is 100,000 BTU, roughly 105.5 MJ, and natural gas bills in the United States are sometimes in therms. A 10 kWh daily load is 34,121 BTU, or 0.34 therm. Check which BTU a document uses if precision to a part in a thousand matters.

The electronvolt in atomic and particle physics

The electronvolt is the energy an electron gains crossing a potential difference of one volt. Since the 2019 SI redefinition it equals exactly 1.602176634 × 10⁻¹⁹ J, because the elementary charge is exact. Photons of visible light carry roughly 1.6 to 3.3 eV, chemical bond energies are a few eV, X-ray photons range up to hundreds of keV, and particle accelerators work in GeV and TeV. One joule is about 6.241509 × 10¹⁸ eV. The unit is practical for individual particles and impractical for everyday amounts: a 1 kWh quantity holds about 2.25 × 10²⁵ eV. Converting between joules and eV involves exponents, so be careful with the power of ten.

Foot pound-force and mechanical work

The foot pound-force is the work done by a force of one pound-force over one foot. It equals 1.3558179483 J, since the pound-force is 4.4482216152605 N and the foot is 0.3048 m. A weight of 10 lb lifted 3 ft involves 30 ft·lbf of work, which is 40.7 J. US engineers specify torque in lbf·ft, the same dimension but a different physical quantity, so a figure of 100 lbf·ft of torque must not be treated as 135.6 J of energy. The newton meter has the same confusion: it is torque when it measures a moment and joule when it measures work. Context tells which, since the symbol is shared.

Fuels, explosives and everyday benchmarks

Benchmarks help judge whether a conversion is reasonable. Gasoline contains roughly 32 to 34 MJ per liter, which is about 9 kWh. One ton of TNT is defined by convention as 4.184 GJ, a standard unit for large explosions, and a megaton of TNT is 4.184 × 10¹⁵ J. A typical alkaline AA cell stores on the order of 10 kJ. A person at rest uses about 80 W, which is 6.9 MJ per day, in line with a 1,650 kcal daily basal need. Annual world energy use is of the order of 600 EJ. The prefixes here, kilo through exa, span fifteen orders of magnitude.

Energy, power and torque are not interchangeable

A watt is energy per time, so a rate cannot be converted to an amount of energy without a duration. A 2 kW heater running for 30 minutes uses 1 kWh, equal to 3.6 MJ. The kWh is a count of energy and the kW a rate, which is why the label kW/h misleads. Heat quantity in joules and temperature in kelvin are also different, linked by the heat capacity of the material. For example, warming 1 kg of water by 1 K takes about 4,184 J, or about 1.16 Wh. Always check that the original quantity is energy before using these units. Kinetic energy follows ½mv², so a 1,200 kg car at 25 m/s carries 375 kJ, about 0.104 kWh, which is the amount a braking system turns into heat in a stop.

Authoritative factors and scope

The joule and the electronvolt are defined in the BIPM SI Brochure. NIST SP 811 gives the thermochemical calorie as 4.184 J, the International Table calorie as 4.1868 J, and the BTU values mentioned above. These are fixed conventions, so the factors in a converter are exact or rounded from exact definitions. The converter changes units for an energy you already know. It does not estimate how much energy a task requires or its cost, and it makes no claims about efficiency. For billing, use the figures printed by your utility, and for nutrition, those on the product label.

Precision and checking

  • Keep the precision justified by the original energy amount.
  • A similarly named calorie or BTU definition may have another factor.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Choose a unit definition

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources

Read the calculation and sourcing methodology →