MEASUREMENT & METHODS

watt hours (Wh): energy unit guide

The Wh selection is an energy unit.

Measurement basis

A watt-hour corresponds to 3,600 joules in the recorded definitions.

Definition conventions

Calories use the thermochemical convention, BTU uses the International Table definition and foot-pounds mean foot-pounds force.

Conversion method

Multiply Wh by 3,600 to read J. The hour is already part of this energy-unit definition.

Reference equivalent of Wh

1 Wh = approximately 3600 J.

Recorded scale factors: 3600 for Wh; 1 for J.

Worked example

Known input: 10 Wh. Reference equivalent: 36000 J. The return conversion gives approximately 10 Wh.

The worked value compares energy without supplying an instantaneous power reading.

Common reference values

Input (Wh)Reference equivalent (J)
13600
518000
1036000
2590000
50180000
100360000

Compare one Wh with other units

Target unitEquivalent of 1 WhDefinition guide
Joules (J)3600Read definition
Kilojoules (kJ)3.6Read definition
Kilowatt-hours (kWh)0.001Read definition
Thermochemical calories (cal)860.420650096Read definition
International-table BTU (BTU IT)3.41214163313Read definition
electronvolts (eV)2.24694326681e+22Read definition
foot pounds (ft·lbf)2655.2237374Read definition
kilocalories (kcal th)0.860420650096Read definition

Energy of one watt over one hour

A watt hour, symbol Wh, is the energy transferred by a power of one watt acting for one hour. Since an hour has 3,600 seconds, 1 Wh = 3,600 J exactly, which is 3.6 kJ or 0.0036 MJ. The hour is not an SI unit but is accepted for use with the SI, and NIST SP 811 lists the watt hour with this value. The kilowatt hour, kWh, equals 1,000 Wh and 3.6 MJ, and it is the usual billing unit for electricity. Because the unit multiplies power and time, 60 W for 2 hours and 120 W for 1 hour are both 120 Wh. Ten 100 W lamps lit for an hour use 1 kWh, the same as one 1 kW heater.

Converting to joules, kilowatt hours and calories

The site lists watt hours against joules (x 3,600), kilojoules (x 3.6), megajoules (x 0.0036), kilowatt hours (x 0.001), thermochemical calories (x 860.42), kilocalories (x 0.86042), international-table Btu (x 3.41214), electronvolts and foot-pounds (x 2,655.22). A 100 Wh battery holds 360 kJ, 0.1 kWh, 86.04 kcal and 341.2 Btu. A food energy label of 2,000 kcal equals about 2,325 Wh, or 2.32 kWh. Going from kWh to Wh multiplies by 1,000, and the reverse divides. All the electrical and thermal factors are tied to the joule, so energy comparisons across heating, cooking and electricity can be done by converting through joules.

From milliamp hours to watt hours

Battery capacity on a label is often in milliamp hours, which is charge and not energy. Energy equals charge times voltage, so Wh = mAh x V / 1,000. A 5,000 mAh phone battery at a nominal 3.7 V stores 18.5 Wh. A power bank of 20,000 mAh at 3.7 V holds 74 Wh, and one of 27,000 mAh at 3.7 V holds 99.9 Wh. A 12 V, 100 Ah battery stores 1,200 Wh, or 1.2 kWh, which is 4.32 MJ. Two batteries with the same mAh can differ greatly in energy if their voltages differ. The nominal voltage is part of the specification, and a figure without it cannot be converted.

Air travel limits for lithium batteries

International aviation rules for lithium-ion batteries are expressed in watt hours. Spare batteries and power banks up to 100 Wh can be carried in cabin baggage without airline approval, and those from 100 to 160 Wh normally need the approval of the airline, with a limit on the number of spares. Larger ones are generally not allowed in passenger aircraft, and spare batteries must travel in the cabin with their terminals protected. A 27,000 mAh pack at 3.7 V is 99.9 Wh and sits just under the first threshold. If a label gives only mAh, the Wh figure can be calculated using the cell voltage, but airlines may want it printed. Rules vary by carrier and country, so check the current guidance.

Run time from stored energy

Dividing energy by power gives time. A 1,200 Wh battery feeding a 300 W load would run for 4 hours in the ideal case. Real systems cannot use all of the stored energy, and inverters waste some, so at 80 percent usable capacity and efficiency the run time is 3.2 hours. A 74 Wh power bank charging a 15 Wh phone could deliver about 4.9 full charges in theory, with conversion losses reducing that to about four. Cold weather lowers the usable energy of lithium-ion cells as well. Labels for power banks refer to energy at the cell voltage, while the output is at 5 V or higher. At an illustrative 85 percent efficiency, 74 Wh gives 62.9 Wh at 5 V, or about 12.6 Ah.

Electricity use in kWh

Electric utilities bill in kilowatt hours. A 1.5 kW heater running for 2 hours uses 3 kWh. A refrigerator averaging 60 W consumes 1.44 kWh a day, and 525.6 kWh in a year of 8,760 hours. An illustrative household using 10,000 kWh per year averages 27.4 kWh a day, or 1.14 kW around the clock. In watt hours these are 3,000 Wh and 1,440 Wh, which are easier to compare for small devices. Electric vehicles are rated in kWh per 100 km or per mile. A 60 kWh pack consuming an illustrative 18 kWh per 100 km would cover about 333 km, before allowing for reserve.

Not the same as watts or amp hours

Dropping the h turns an energy into a power. A 500 Wh battery and a 500 W device are different quantities, and relating them needs a time interval. A watt hour also differs from an amp hour, which measures charge. A figure such as 100 Ah means nothing for energy until the voltage is known. The unit symbol is Wh, or W h or W·h, and a slash such as W/h is wrong because that would mean a rate of change of power, which is a different quantity altogether. Writing out watt hours on first mention in specifications, and keeping both mAh and Wh for battery products, gives readers the information to check one against the other.

Home batteries and the usable fraction

Home storage systems are sold by capacity in kWh, and typical residential units hold around 5 to 15 kWh. The stated figure may be the total or the usable capacity, and the two can differ by 10 percent or more, since batteries are kept away from full discharge to protect life. A 13.5 kWh battery with 90 percent usable capacity supplies 12.15 kWh, which would run a 500 W load for 24.3 hours. The conversion to Wh, 12,150, is trivial. The harder part is deciding which capacity applies, and the datasheet usually specifies whether it is nominal, usable or measured at a given discharge rate.

Notation and sources

Spell the unit as watt hour or watt-hour and write the symbol Wh with a capital W and a lowercase h. The prefix k belongs in front, so kWh is correct and KWH is not standard. A space separates the number from the unit, as in 18.5 Wh. Tables that list kW for power beside kWh for energy should label the columns clearly. The SI Brochure accepts the hour for use with SI units, and NIST SP 811 gives 1 kW h = 3.6 x 10^6 J. State the battery voltage or the load next to any Wh figure, so that a later reader can check the arithmetic.

Precision and checking

  • Keep source energy precision.
  • Retain h in Wh.

Reference numbers are displayed with up to twelve significant digits. That display does not add precision to a rounded measurement. Keep source and target quantities compatible, confirm symbol case and regional conventions, and round the final result to precision justified by the input. Factors involving π or repeating fractions use finite numerical precision.

Use a working converter

Source and verification scope

The reference values and examples use the versioned unit definitions shared with the linked converters. Source dates identify the stated access or verification scope. A reverse calculation checks arithmetic and direction, but it does not independently verify a definition. Computandum is independent of the cited organizations, and the citations do not imply endorsement of this guide or a real application.

Sources