Permits in lb/h, models in g/s
Air permits and emission inventories in the United States commonly list pollutant rates in pounds per hour, and the dispersion models used to assess them, AERMOD among them, take emission rates in grams per second. An environmental consultant who moves a stack rate from a permit table to a model input does this conversion many times. The same need arises with fuel feeds, test-stand flows and process streams specified by American vendors for equipment run on metric instruments. This page multiplies lb/h by 0.125997880556 to give g/s. The result is a mass flow of the substance in question, so it applies to any material. Check the model documentation for the unit it expects. Some tools accept grams per second per area for area sources, and that is a different quantity again, so confirm whether the field wants the total rate for the source or a rate spread over its footprint before you type the converted figure.
How 0.125998 is built
The international pound is exactly 453.59237 g, and an hour has 3,600 s. Dividing gives 0.12599788 g/s per lb/h, so the formula is g/s = lb/h × 0.125997880556. NIST SP 811 lists the pound, and the SI Brochure accepts the hour. By hand, divide by 8, which is a slight underestimate: 0.125 against 0.126. A better shortcut is to divide by 7.94, since 1 g/s is 7.9366 lb/h. A rate of 1 lb/h is 0.126 g/s, 2.5 lb/h is 0.315 g/s and 100 lb/h is 12.6 g/s. The page keeps the full stored factor, so repeated conversions do not drift. If you convert a whole table of sources, a spreadsheet formula that multiplies by 0.125997880556 gives the same answers, and a couple of spot checks against this page confirm that the column was filled correctly.
Reading 1.26 g/s for the 10 lb/h default
The page opens with 10 lb/h and returns 1.25998 g/s. That is a bit more than a gram every second, or about the weight of a paperclip arriving each second. In a permit, 10 lb/h of a pollutant is a sizeable hourly rate, and the model would treat it as 1.26 g/s steady, with no variation across the hour unless the input file describes one. If a result is larger than your input, the menus are reversed, since the second is far shorter than the hour and the gram far smaller than the pound, the net effect being a reduction to about one eighth. As a check, the g/s figure must be close to 12.6 percent of the lb/h figure.
A stack example
Suppose a boiler stack has a permitted emission limit of 45 lb/h for a pollutant. In a model input that is 5.67 g/s. A smaller source emitting 2.5 lb/h is 0.315 g/s, and a larger one at 250 lb/h is 31.50 g/s. A common slip is to enter the lb/h value directly into a field that expects g/s, which overstates the rate by a factor of about eight. Another is to use a daily or annual limit without dividing by the operating hours. These are illustrative figures for the arithmetic only, and the actual limits and the modeling method come from the permit and the governing agency guidance. Stack parameters such as height, temperature and exit velocity matter as much as the rate itself in a dispersion run, and none of them changes with the unit of the emission rate.
From an hourly rate to a yearly total
A source that runs continuously at 1 lb/h emits 8,760 lb in a 365-day year, which is 4.38 US short tons. The same source at 0.126 g/s emits about 3,973 kg over that period. Inventory reports list annual tons per year, while models need a short-term rate in g/s, so one source is often expressed three ways, and the conversions must agree with one another. If the source runs only part of the year, scale by hours of operation. The conversion on this page changes only the units of the instantaneous rate. It says nothing about how many hours a source operates, and the totals depend on the permit conditions and the operating records.
Timing a flow with a stopwatch
Small flows from a lab burner, a gas generator or a hand feeder are sometimes measured over a few seconds. If a feeder delivers 12.6 g in 10 seconds, the rate is 1.26 g/s, which is 10 lb/h. A delivery of 31.5 g in 5 seconds is 6.3 g/s, or about 50 lb/h. Short windows have large reading errors from the starting and stopping of the timer, so use the longest interval that does not drain the supply, and repeat the test. This page does the arithmetic, and it assumes that the measurement behind the number is sound. A converted figure carries the same uncertainty as the original timed weighing. Weigh on a scale whose resolution is a small fraction of the collected mass, and tare the container before the test so that the reading is the material alone.
Grams per second back to pounds per hour
To convert the other way, select grams per second as the source and pounds per hour as the target. One gram per second is 7.9366 lb/h. A rate of 5 g/s equals 39.68 lb/h, 0.5 g/s equals 3.97 lb/h and 12 g/s equals 95.24 lb/h. A model result in g/s that has to be compared with a permit limit in lb/h goes through this step. Round the answer to the precision of the limit, which is commonly two or three significant digits. If you report both, say the unit with each figure and mention the factor, 0.125998 g/s per lb/h, so that the reviewer can verify the arithmetic without opening the model file.
Concentration is a different quantity
A mass flow in g/s says how much of a substance leaves a source each second. It is not a concentration in the air, which a model computes from the flow, the stack conditions and the weather. Readings in ppm or mg/m³ are separate quantities, and converting between them needs gas volume, temperature and molar mass. This page does none of that. It takes a mass per time and states it in another mass per time. When someone asks for the rate in g/s, they want the mass of the pollutant, not the mass of the stack gas, so make sure you start from the right stream before you convert.