Two systems of units in one literature search
Biophysics and cell biology papers today report forces in piconewtons, but a good deal of the earlier work in cell mechanics, colloid science and fluid physics was written in the centimeter-gram-second system, where force is measured in dynes. A student reading both has to put the numbers on one scale before comparing a cell adhesion figure from an older review with a single-molecule measurement from a current article. This page converts piconewtons into dynes in one step. It also helps with textbooks that carry over the cgs convention, where surface tension appears in dynes per centimeter and viscosity in poise, and it keeps the exponent right when the numbers are tiny. It is equally handy for a lab course that asks students to repeat a calculation from an older paper, where the original table lists dynes and the instrument in the room reports piconewtons.
Ten million piconewtons in a dyne
The dyne is the force that gives a mass of one gram an acceleration of one centimeter per second squared, which works out to 10^-5 N. The piconewton is 10^-12 N, so a dyne holds 10^7 pN. The formula is dyn = pN × 10^-7. The newton and the SI prefixes are defined in the BIPM SI Brochure, and NIST SP 811 lists the dyne as a cgs unit with 1 dyn = 10^-5 N. The factor is exact. By hand, move the decimal point seven places to the left: 6 pN is 6 × 10^-7 dyn, and 65 pN is 6.5 × 10^-6 dyn. The dyne is a small unit by everyday standards, and the piconewton is smaller still.
Reading 1e-6 dyn for the default
The page opens with 10 pN and returns 0.000001 dyn, that is 1 × 10^-6. Other inputs scale the same way: 100 pN is 1 × 10^-5 dyn, and 250 pN is 2.5 × 10^-5 dyn. The values are small because a dyne is already a tiny force next to the weight of a coin, and a piconewton is a ten-millionth of that. When the result prints with an exponent, copy the exponent and the unit, not a rounded decimal with a string of zeros. As a quick test, any piconewton input below ten million must produce a dyne value below one, and a result above the input means the From and To units were swapped.
Forces of single molecules in dynes
Molecular motors that move along filaments are reported to produce forces of several piconewtons, and stretching a DNA molecule until it overstretches takes a force near 65 pN, according to the single-molecule literature. In dynes those figures are 6 × 10^-7 and 6.5 × 10^-6. They are listed here as typical orders of magnitude and not as values for any particular experiment, since results depend on the molecule, the buffer and the instrument. Converting them lets you compare an older paper that quoted nanodynes or microdynes with a newer one that quotes piconewtons. A force of 0.002 dyn, for example, is 2 × 10^4 pN, or 20 nN, which falls in the range of whole-cell measurements.
Spring constants and Hooke's law at the nanoscale
Instruments such as the atomic force microscope convert a measured deflection into force with Hooke's law, F = kx. A cantilever with a spring constant of 0.05 N/m that deflects by 2 nm exerts 0.05 × 2 × 10^-9 = 10^-10 N, which is 100 pN, or 10^-5 dyn. The cgs form of the same spring constant is 50 dyn/cm. Older data sheets and papers use dynes per centimeter, so a converter helps when the spring constant and the deflection come from different sources. Calibration of the spring constant is the main source of uncertainty in such a measurement, and the unit change does not remove it.
Surface tension and other dyne-based quantities
The dyne survives in a few places outside biophysics. Surface tension of liquids is still listed in dyn/cm in some handbooks and on tensiometer displays, and one dyn/cm equals one mN/m. Water at room temperature is near 72 dyn/cm, which is 72 mN/m. Coating, printing and cleaning specifications often state the surface energy of a substrate in dyn/cm. These are forces per length, so a force in piconewtons does not convert to them without a length. The dyne itself is a force, and this page changes only the unit of a force. Keep the length in the denominator when you read a data sheet. A tensiometer that reports 45 dyn/cm for a cleaning solution is reporting 45 mN/m, and a printing specification that asks for a substrate at 38 dyn/cm is asking for 38 mN/m, so no factor of ten million is involved in those cases, unlike a conversion of a bare force.
Dynes back to piconewtons
Choose dynes as the From unit and piconewtons as the To unit to reverse the direction. One dyne is 10^7 pN, and 0.002 dyn is 2 × 10^4 pN. The page multiplies by ten million, so the decimal point moves seven places to the right. Use the reverse direction when you meet a force in a classic paper and want to compare it with modern instrument ranges, which are usually quoted in piconewtons. Optical and magnetic tweezers typically operate from a fraction of a piconewton to tens or hundreds of piconewtons, depending on the trap and the bead, and the converted figure shows quickly whether an old value falls in that range. A value of 3 × 10^-6 dyn, for instance, is 30 pN, comfortably inside the working range of a typical trap, while 3 × 10^-3 dyn is 30,000 pN, or 30 nN, which would call for a stiffer cantilever or a micropipette setup.
Quoting a trap force to one or two digits
Single-molecule forces are usually quoted to one or two significant figures, and the calibration of a trap or a cantilever limits the accuracy to a few percent at best. A converted value should carry the same number of digits. Writing 6.5 × 10^-6 dyn is honest, and writing 0.0000065000 dyn is not. The conversion factor is exact, so it adds no uncertainty. If a program prints a tail such as 9.999999999999999e-7, the extra digits come from binary arithmetic. Read them as 1 × 10^-6, and round before the figure goes into a report or a slide.
Surface tension in dyn/cm needs a length too
Carrying a trap force into cgs units changes the number and leaves the experiment as it was. It does not calibrate an instrument, convert a force per length such as surface tension without that length, or judge whether a force is physiologically meaningful. A force on a molecule depends on the loading rate and the direction, and the same number can mean different things in different experiments. Use the methods section of a paper and the manufacturer calibration notes for those decisions. The converter keeps the powers of ten consistent when you carry numbers from one system of units to another.