Two units from different centuries of physics

The dyne belongs to the centimeter-gram-second system that physicists used before the SI took over, and the piconewton belongs to biophysics laboratories that measure the pull of single proteins. They rarely meet in one document, which is why a conversion page is useful when they do. A review article that compares an old surface-force measurement with a modern optical tweezers result has to put both on one axis, and the gap is seven orders of magnitude. One dyne contains ten million piconewtons, so even a force of 1e-6 dyn, which looks negligible in CGS units, is already 10 pN, a force that matters a great deal to a motor protein walking along a filament.

How 1e7 is derived

The dyne is defined as one gram centimeter per second squared, which is 1e-5 N in SI. The prefix pico means 1e-12, a trillionth, as set out in the BIPM SI Brochure, so a piconewton is 1e-12 N. Dividing 1e-5 by 1e-12 gives 1e7, and the formula on the page is pN = dyn × 10,000,000. Going back, one piconewton equals 1e-7 dyn. The factors are exact because both units are defined through the newton. A common error is to confuse pico (1e-12) with nano (1e-9) or micro (1e-6). Each step is a factor of 1,000, so writing nN where the source says pN changes a force by 1,000 times and turns a gentle protein pull into a bond-breaking load.

What the default 10 dyn looks like in piconewtons

The page opens with 10 dyn, which converts to 100,000,000 pN, or 1e8 pN. That is a force of 100 µN, vastly larger than anything a single molecule can exert, so the default is a test number and not a biophysical value. It does show the scale gap clearly: a result with eight digits for a force that a human hand would not feel. If you want a molecular-scale case, try 0.000001 dyn, which gives 10 pN. Entering very small dyne values is where the page earns its keep, since the exponents get long and a slip of one place changes the force tenfold. Read the output carefully if it appears in scientific notation, and check the sign of the exponent.

Motor proteins and stall forces

Single-molecule experiments report forces in piconewtons because that is the size of the effect. Kinesin-1 stalls at about 6 pN under load in optical trap experiments, and myosin motors produce a few piconewtons per step. RNA polymerase can generate forces in the range of 20 to 30 pN before stalling. In dynes, 6 pN is 6e-7 dyn, and 25 pN is 2.5e-6 dyn. These values come from published experiments and vary with conditions such as ATP concentration, so quote the specific paper when you rely on them. The page does not model any biology. It restates a force you already know on a different scale, which helps when a classic mechanics source gives results in dyn and a molecular biology source gives them in pN.

Stretching DNA and unfolding proteins

Force-extension experiments on DNA show an elastic regime at tens of piconewtons and an overstretching transition near 65 pN, a value widely reported for double-stranded DNA. Protein domains such as titin immunoglobulin modules unfold at forces of order 150 to 300 pN in atomic force microscopy pulling experiments. In dynes, 65 pN equals 6.5e-6 dyn and 200 pN equals 2e-5 dyn. For comparison, the weight of a single bacterium of about 1 pg is roughly 0.01 pN, so even the weakest molecular forces dwarf gravity at this scale. The numbers are typical, not fixed, because pulling speed and buffer conditions shift them, and any paper you rely on should be consulted for its own values.

Optical traps, calibration and noise

Optical tweezers trap a bead in a focused laser beam and act as a spring with a stiffness of roughly 0.01 to 0.1 pN per nanometer. A bead displaced by 100 nm in a trap with 0.05 pN/nm stiffness feels 5 pN, which equals 5e-7 dyn. Calibration uncertainties of 5 to 10 percent are normal, and thermal motion adds fluctuations that set a noise floor of a fraction of a piconewton in typical bandwidths. The unit conversion cannot improve any of that, and quoting dyn values to many digits would suggest precision the experiment lacks. When you report a force, give the stiffness calibration method and the sampling bandwidth alongside the number, whichever unit you choose.

Reverse direction and worked arithmetic

To turn piconewtons into dynes, divide by 10,000,000, or multiply by 1e-7. A force of 5 pN is 5e-7 dyn, 0.8 pN is 8e-8 dyn, and 150 pN is 1.5e-5 dyn. Going forward, 3e-7 dyn becomes 3 pN, and 0.002 dyn becomes 20,000 pN. Writing the exponent form is safer than counting zeros, and this page accepts decimal input, so enter 0.0000005 for 5e-7 if scientific notation is not convenient. After converting, compare the result with a known anchor, such as the 6 pN kinesin stall. If your force comes out near 6 million piconewtons, the exponent has slipped by a factor of a million somewhere between the source and the page.

Choosing between pN, nN and dyn in a paper

Readers in biophysics expect pN, and expect nN once forces exceed a few hundred piconewtons, because 1,000 pN is 1 nN. Using dyn in a modern biophysics paper would look odd, but a chemistry or materials audience may still encounter it in older surface force literature. A dyne is 10,000 nN and 10,000,000 pN, so a result of 1e-4 dyn is 1 nN and also 1,000 pN. Keep one unit through a table and convert only at the edges. If your audience includes both groups, give the SI value first and the dyne value in parentheses, which makes comparison with older data possible without forcing every reader to convert.

Work per step against thermal energy

Forces in piconewtons are easiest to judge by the work they do over molecular distances. One piconewton acting over one nanometer does 1e-21 J, which is written as 1 pN·nm. Thermal energy at room temperature, kT, is about 4.1 pN·nm. A kinesin step of roughly 8 nm against a 6 pN load therefore costs about 48 pN·nm, or 4.8e-20 J, close to twelve times kT. The same force of 6 pN is 6e-7 dyn, and 8 nm is 8e-7 cm, so in CGS terms the work is 4.8e-13 erg, which equals the same 4.8e-20 J. Working the problem in either system gives one answer, and the conversion on this page is the bridge between them. The numbers are typical published magnitudes, and any specific motor needs its own source.