Per-bit and per-switch energy figures
Integrated circuit and photonics papers quote the energy of an operation in picojoules or femtojoules, depending on how small the figure is. A logic gate switching, a memory cell write or a modulator driving one bit may be listed at a fraction of a picojoule, and the same table can switch to femtojoules for the better entries. Comparing two parts means reading both columns in one unit. This page multiplies the picojoule value by 1,000, so that 0.35 pJ becomes 350 fJ and the default of 10 pJ becomes 10,000 fJ. Designers, reviewers and students can use it to line up numbers from different sources. Because the factor is only a thousand, the page is most useful as a check on a long column that was converted by a script or by hand.
Multiplying by a thousand
Femto is 10^-15 and pico is 10^-12, so one picojoule contains 1,000 femtojoules. The formula is fJ = pJ × 1,000. The BIPM SI Brochure and NIST SP 811 define the prefixes, and the ratio is exact. The decimal point moves three places to the right: 2.5 pJ becomes 2,500 fJ, and 0.04 pJ becomes 40 fJ. In the other direction, 800 fJ is 0.8 pJ. The page works in floating point, so the default 10 pJ may appear as 9999.999999999998 fJ. That is 10,000 fJ, and rounding to the number of figures in your data removes the trailing digits.
Sorting a mixed-unit table by the converted numbers
The default of 10 pJ returns 9999.999999999998 fJ on the page. A value of 1 pJ gives 1,000 fJ, 0.35 pJ gives 350 fJ, and 47 pJ gives 47,000 fJ. Going back, 120 fJ equals 0.12 pJ, and 5,000 fJ equals 5 pJ. A good habit is to check whether the output has three more digits before the decimal point than the input, or three fewer after it, which is the signature of a factor of 1,000. When a table mixes units, sorting by the converted numbers puts the entries in true order, while sorting the raw text would not.
Link power from energy per bit
Electrical and optical links are compared by the energy they spend per transferred bit. Power equals energy per bit times bit rate, so 5 pJ per bit at 10 Gb/s is 5e-12 × 1e10 = 0.05 W, which is 50 mW. A link that reaches 500 fJ per bit, which is 0.5 pJ, uses 5 mW at the same speed. A switch or a processor with hundreds of such lanes multiplies these amounts, and the heat adds up quickly. The values in this paragraph are illustrative and do not describe a specific product. The converter handles the unit step, and a data sheet gives the real energy per bit under stated conditions.
Optical pulses and photon counts
A short optical pulse can carry an energy in the femtojoule range. At 550 nm, a photon has about 2.25 eV, which is 3.6 × 10^-19 J or 3.6 × 10^-4 fJ. A pulse of 100 fJ therefore contains about 277,000 photons. Photodiode and image sensor pixels collect pulses of this size, and the number of photons sets the shot noise. A pulse measured at 0.1 pJ is the same 100 fJ, and the page confirms the equivalence in one step. If you work with sensitivity specifications, check whether the sheet states energy per pulse, per pixel or per area, because the quantity is not interchangeable.
Memory and logic energy tables
Energy tables for memory arrays and logic gates list a write or switch energy per cell or per gate, and papers may express the numbers in fJ for small cells and in pJ for larger structures such as an SRAM access or a register file read. A hypothetical gate that spends 2 fJ per switch and toggles 10^9 times a second burns 2e-15 × 1e9 = 2 µW. If a block has a million such gates and half of them toggle at a time, the power is around a watt in total, though real activity factors are much lower. The page converts the energy unit and does not estimate activity or leakage.
From femtojoules to picojoules
Choose femtojoules as the From unit and picojoules as the To unit to scale up a small figure. A value of 75 fJ is 0.075 pJ, 2,400 fJ is 2.4 pJ, and 10 fJ is 0.01 pJ. When a report lists energies of many components, converting everything to the larger unit keeps the numbers near one and easier to compare, as long as no value becomes a long string of zeros. A target of two or three digits before the decimal point is a reasonable guide. If one entry in a table sits far below the rest, a different unit for that row can hide its importance, so consider using one unit for the whole table. If a figure must be given in both units for a reader, put the second one in parentheses and keep the first as the primary value.
Notation and mixed prefixes
In plain text, fJ and pJ look alike in small fonts, and typing a capital F or P changes the meaning of the symbol. The symbol FJ is not a valid SI unit, and a capital P would stand for peta, a factor of 10^15. Spreadsheets that auto-capitalize the first letter of a cell can introduce the error silently. A habit that helps is to spell the unit in the header of every column and to keep an unconverted source column next to the converted one. Reviewers can then compare against the paper that the figure came from, and a prefix slip stands out as a factor of 1,000 between two columns.
Supply voltage hides the gap between two papers' energies
The page changes only the unit of an energy. It does not compute the energy of an operation from circuit parameters, estimate the power of a system or judge whether a figure is competitive. Reported energies depend on supply voltage, temperature, process, workload and what is included in the count, such as drivers and clocking. Two numbers from different papers may not be comparable even after the conversion. Read the measurement conditions in each source, and treat the converter as a way to avoid arithmetic mistakes when you place the numbers side by side. Supply voltage is the usual cause of a hidden gap, since switching energy scales roughly with its square.