Fifteen orders of magnitude in one step
A nanowatt is the power scale of the faintest signals that a receiver can pick up. A megawatt is the power scale of a wind turbine, a locomotive or a large industrial plant. The ratio between them is a one followed by fifteen zeros, which is more than any everyday conversion has to bridge. People reach this page for a few reasons. Some are checking exponent handling in a script or a spreadsheet. Some are working through a textbook problem about the range of power in engineering. Others are comparing two published numbers, one from a radio or sensor context and one from an energy context, and want to see how far apart they are. The converter changes only the unit. A watt is one joule per second, and the conversion leaves the power exactly as supplied. It does not estimate the power of any device.
The factor and the default result
The page formula is MW = nW × 10^-15. With the default input of 10 nW, the result is 1 × 10^-14 MW, which written as a decimal is 0.00000000000001, with thirteen zeros after the point before the 1. The converter may print it as 1e-14. The factor is exact. Both the nano and the mega prefixes are defined as powers of ten in the International System of Units, and NIST Special Publication 811 lists them. A value of 250 nW converts to 2.5 × 10^-13 MW, and a value of 4,000 nW, which is 4 µW, converts to 4 × 10^-12 MW. In the opposite direction, 1 MW is 10^15 nW, a number with sixteen digits, and 3.5 MW is 3,500,000,000,000,000 nW.
Climbing the prefix ladder
The route from nano to mega passes through every common power prefix, and each step is a factor of 1,000. Nanowatts to microwatts divides by 1,000, microwatts to milliwatts by 1,000, milliwatts to watts by 1,000, watts to kilowatts by 1,000, and kilowatts to megawatts by 1,000. That is five steps and a factor of 10^15 in all. Going through the intermediate units is a good way to check a result by hand. For 250 nW the steps give 0.25 µW, 0.00025 mW, 0.00000025 W, 0.00000000025 kW and 0.00000000000025 MW, which is 2.5 × 10^-13 MW. The converter lists all of these units, so you can follow the chain by changing the target unit one step at a time and confirm that the direct result matches.
How large a megawatt is
One megawatt is a million watts. A modern onshore wind turbine is commonly rated at a few megawatts. A large diesel-electric locomotive has an engine of a few megawatts, and a big data center can draw tens of megawatts. A conventional power station may have a capacity of hundreds of megawatts, and the largest plants exceed a thousand. In mechanical units, 1 MW is about 1,341 mechanical horsepower, since one mechanical horsepower is 745.7 W. These are general orders of magnitude from engineering practice. They help to place the megawatt, but they are not figures for any specific installation. A power rating is a statement about the maximum rate of energy conversion, and it does not say how much energy is produced over time.
How small a nanowatt is
A nanowatt is a billionth of a watt, and it is the scale of very weak signals. In radio engineering, a level of minus 60 dBm is 1 nW, because 0 dBm is 1 mW and each 10 dB is a factor of ten. A received signal in the range of minus 90 to minus 60 dBm is typical of a wireless link at moderate distance, which is between 1 pW and 1 nW. Signals from navigation satellites arrive at the ground at about minus 130 dBm, which is 10^-16 W or 10^-7 nW. Thermal noise in a 1 MHz bandwidth at room temperature is about 4 × 10^-15 W, or 4 × 10^-6 nW. These values show that a nanowatt is already a strong signal in some contexts. The converter does not model any of those systems and treats the input as a bare power.
A second example from a sensor node
Suppose a wireless sensor node sleeps at 250 nW and wakes for brief periods at 30 mW. In megawatts, the sleep power is 2.5 × 10^-13 MW and the active power is 3 × 10^-8 MW. The ratio of active to sleep power is 30 mW divided by 250 nW, which is 30,000,000 nW divided by 250 nW, or 120,000. The average power depends on the duty cycle. If the node is active for 0.1 percent of the time, the average is 0.001 × 30 mW plus 0.999 × 250 nW, which is about 30,000 nW plus 250 nW, so around 30,250 nW. The sleep power is then less than 1 percent of the average. The values are invented for illustration. The example shows why a conversion to a common unit matters before a comparison is made.
Power versus energy
Megawatts and nanowatts both describe rates. A device that draws 1 MW for one hour has used one megawatt-hour, which is 3.6 gigajoules. A device that draws 250 nW for one hour has used 250 nW times 3,600 s, which is 0.0009 J, or 900,000 nJ. The units used on utility bills, kilowatt-hours and megawatt-hours, measure energy, while the units on this page measure power. Mixing them is a common error, for example saying that a plant produces 100 MW per hour. The correct statement is that it produces 100 MW of power, or 100 MWh of energy per hour. The converter handles only the power. If you have an energy figure and a time, divide to find the average power before you convert.
Negative exponents in results
The result for most inputs on this page is a number with a large negative exponent. That is expected, because the nanowatt is so small compared with the megawatt. Do not read it as zero. A result of 1e-14 means 1 × 10^-14, which is small but not zero, and the full digits are preserved by the computer. Spreadsheet programs may round or display zero for very small numbers if the cell format is set to a fixed number of decimals. Change the format to scientific notation, or use a smaller target unit for display. When writing the result in a document, give the exponent in the form 10^-14 and the unit symbol MW. A trailing digit such as in 1.0000000000000001e-14 is a binary rounding artifact and carries no meaning.
Common mistakes
Prefix case is the biggest source of error. A lowercase m means milli and an uppercase M means mega, so mW and MW differ by a factor of 10^9. The page labels use MW for megawatts, and the unit list also includes mW for milliwatts. Another error is to confuse megawatts with megajoules or megawatt-hours. A third is to forget a step on the ladder and use 10^12 or 10^18 instead of 10^15. A fourth is to use a comma and a period incorrectly in a long number, which turns 3,500,000,000,000,000 into a different quantity. Writing the number in scientific notation, as 3.5 × 10^15, avoids that problem. Finally, check that the input really is a power in nanowatts and not a level in dBm, which needs a logarithmic conversion first.
Optical power meters and the bottom of the range
Optical power meters used in fiber networks read in dBm, microwatts or nanowatts. A transmitter might launch 1 mW into a fiber, which is 0 dBm, and after a long link with losses of 30 dB the receiver sees 1 µW, which is 1,000 nW. A weak received signal of minus 40 dBm is 100 nW, and one of minus 50 dBm is 10 nW, the default value on this page. Expressed in megawatts, 10 nW is 10^-14 MW, a number that no fiber technician would use, but converting it shows how the optical budget compares with the power of the laser driver supply, which might be a few watts. The loss in decibels between two points is 10 times the base-10 logarithm of the power ratio, so a drop from 1 mW to 10 nW is 50 dB. The numbers are illustrative, not the specification of any link.
Checking a result with a one-line script
Because the factor is a pure power of ten, you can verify any result with a single line in a spreadsheet or a script. Multiply the nanowatt value by 1e-15 and compare with the converter. For 250 nW the product is 2.5e-13. For 4,000 nW it is 4e-12. For 30,000,000 nW, which is 30 mW, it is 3e-8 MW. The agreement is exact up to floating-point rounding in the last digit. Tests of this kind are useful when you build your own tool and want to confirm that the exponent is applied in the right direction. A common bug is to multiply by 1e15 when the intent was to divide, which turns a tiny value into an enormous one. Printing both the input and the output with their unit symbols in a log line makes such a bug obvious at once.
Scope and sources
The page converts a known power between SI-prefixed units and other power units. It does not estimate the power of a device, the output of a plant or the strength of a signal. It makes no statement about safety, licensing or regulatory limits, which depend on the application and the jurisdiction. The prefix values and the watt come from NIST Special Publication 811 and the BIPM SI Brochure. The conversion is exact up to floating-point representation. For engineering decisions, use the rated power from the manufacturer and the standards that apply, and use this page as a quick check of the scale.