A small error against a full supply

Calibration labs, electronics students and engineers who specify voltage references all end up comparing a very small number with a very large one. A reference that outputs 2.5 V may drift by a few hundred nanovolts over a day, and a data sheet states that drift in nanovolts. To see what fraction of the output it is, both values must share a unit. This page divides the nanovolt value by one billion and gives volts. A 250 nV drift becomes 2.5e-7 V, a figure that sits comfortably next to 2.5 V in a spreadsheet and lets you compute the relative change directly.

1,200 nV as 0.0000012 V and 5,000,000,000 nV as 5 V

Nano is 10^-9, so a nanovolt is a billionth of a volt. The formula is V = nV × 10^-9. NIST SP 811 and the BIPM SI Brochure define the prefix, and the factor is exact. Written out, 1,200 nV needs nine places and ends as 0.0000012 V, while 5,000,000,000 nV is a plain 5 V. A shortcut is to go through microvolts and millivolts, in three steps of 1,000 each. Counting nine places in a long string is error-prone, so the page prints small results in scientific notation, where the exponent shows the shift. If the output is bigger than the input, the units are set backward.

A 250 nV reference drift against a 2.5 V reference

The page starts with 10 nV and returns 1e-8 V, which is 0.00000001 V. In e notation the exponent of minus eight shows at a glance that the value is ten times a billionth. Other examples are a 1,200 nV thermal offset, which gives 1.2e-6 V, and a 250 nV reference drift, which gives 2.5e-7 V. Divide the drift by a 2.5 V reference and the relative change is 1 × 10^-7, or 0.1 part per million. That kind of comparison, a tiny voltage as a fraction of a large one, is the main reason to convert to volts rather than to a smaller unit.

ADC step size and the volt scale

A 16-bit converter with a 3.3 V reference has 65,536 steps, and one step is 3.3 divided by 65,536, about 5.0354 × 10^-5 V. In nanovolts that is roughly 50,354 nV. A designer who needs a resolution of 10,000 nV from a sensor will see at once that this converter cannot deliver it without an amplifier ahead of it. The same comparison works for any bit depth and reference: compute the step in volts, convert to nanovolts or microvolts to see it in the unit of the signal, and decide on the gain. The page handles the unit shift for the number you type and leaves the amplifier choice to you.

Everyday voltages in nanovolts

Putting familiar voltages into nanovolts shows how large the unit is when it is small. A 1.5 V AA cell is 1,500,000,000 nV, a 3.3 V logic supply is 3,300,000,000 nV and a 5 V USB rail is 5,000,000,000 nV. A household outlet at 120 V is 1.2 × 10^11 nV. Nobody measures these in nanovolts, but a database or a teaching exercise may use them. Choose volts as the From unit and nanovolts as the To unit to reverse the direction. The page multiplies by one billion, and for outlet voltages the result is a number with twelve digits, which is easy to check by counting.

Thermoelectric offsets in sensor wiring

When two dissimilar metals join, a thermoelectric voltage appears, and a gradient of a few degrees across a connector can produce microvolts. In a circuit that measures a few millivolts, that is a small error, but in a circuit that measures hundreds of nanovolts it is the dominant one. Technicians expect it, minimize it with matched materials and covers over the terminals, and cancel the rest by reversing the source polarity. If a test shows an offset of 1,200 nV, or 1.2 × 10^-6 V, against a signal of 5 mV, the error is about 0.024 percent. That calculation is the type of check this page supports.

Parts per million from nanovolts

Reference and calibrator specifications often state stability in parts per million of the output. To turn a drift in nanovolts into that form, convert it to volts and divide by the output voltage. A 250 nV change on a 2.5 V reference is 2.5 × 10^-7 V divided by 2.5 V, which is 1 × 10^-7, or 0.1 ppm. A 1,200 nV offset on a 5 V supply is 2.4 × 10^-7, or 0.24 ppm. A 10 µV drift on a 10 V reference is 1 ppm. These numbers show why precision references are specified in nanovolts and microvolts even though they output several volts. The conversion on this page supplies the numerator, and the division by the output is a separate step you do yourself.

Significant figures and spreadsheet habits

A reading of 10 nV with a meter that resolves 1 nV has two significant figures, so 1.0 × 10^-8 V is the honest way to write it. Spreadsheets may show 0.00000001, 1E-08 or 0 depending on the cell format, and a fixed format with two decimals would hide the whole value. Set the cell to scientific notation or keep the data in nanovolts and convert only for display. When you share a file, label each column with the unit so that a later reader does not have to guess whether 10 means 10 nV or 10 V. A conversion that has been done once and clearly labeled does not have to be repeated. If a colleague later asks how a number was obtained, the stated factor of 10^-9 answers the question in one line.

Beyond the unit change

The page restates a voltage in volts. It does not tell you whether a nanovolt value is within the accuracy of your meter, whether it is a peak or RMS figure, or whether it is an offset, a signal or noise. It also does not cover safety for the circuit where the voltage appears. For those matters, rely on the instrument manual, the data sheet of the reference or sensor and the procedures at your workplace. The converter is a check on the arithmetic of the powers of ten, and it works with any number you enter, so confirm that the source value is the one you mean. If the figure came from a data sheet, note the conditions listed beside it, such as temperature and load.