Neighboring prefixes on a bench
Nanocoulombs and microcoulombs are the two prefixes you meet most often when you work with small capacitors, test pulses and static charge. A 100 nF capacitor charged to 5 V holds 500 nC, while a 1 µF capacitor at the same voltage holds 5 µC, and documents list them in whichever prefix looks convenient. This page divides the nanocoulomb value by 1,000, which is the same as multiplying by 0.001, and shows microcoulombs. A reading of 10 nC becomes 0.01 µC. Because the step is only a factor of one thousand, the common error is to shift the decimal point by two or four places instead of three, and the page avoids that.
One thousand nanocoulombs per microcoulomb
Nano is 10^-9 and micro is 10^-6, so a microcoulomb is 1,000 nanocoulombs. The BIPM SI Brochure defines the prefixes, and the coulomb is the charge moved by one ampere in one second. The conversion is exact: move the decimal point three places to the left to go from nC to µC, and three to the right for the reverse. The micro sign µ looks like a letter u, and in plain text a charge may be written as uC. In handwritten notes, nC and µC are easy to confuse, so write the unit in full the first time you use it.
Ten nanocoulombs as microcoulombs
With 10 nC entered, the page returns 0.01 µC. A pulse of 250 nC is 0.25 µC, and 1,800 nC is 1.8 µC. In the other direction, 3.3 µC equals 3,300 nC, and 0.47 µC equals 470 nC. A check is the digit count: the microcoulomb value has the same digits as the nanocoulomb value with the decimal point shifted three places. If the page returns a number a million times smaller than the input, the target unit was set to millicoulombs. Landmarks help too: 1,000 nC is one microcoulomb, and 1,000,000 nC is one millicoulomb.
Capacitor charge at different sizes
The relation Q = C × V gives the charge of a capacitor. A 220 nF part at 12 V holds 2,640 nC, which is 2.64 µC. A 4.7 µF part at 3.3 V holds 15.51 µC, which is 15,510 nC. Power supply designers compare these numbers with the charge the load takes per switching cycle, and a value written in the wrong prefix leads to a capacitor that is a thousand times too small or too large. The values are example components and not recommendations. The page converts the charge, and the choice of a capacitor depends on ripple, temperature, voltage rating and the datasheet of the part. Charge also tells you how long a capacitor can carry a load. The 4.7 µF part holds 15.51 µC at 3.3 V, so a steady 1 mA draw would empty it in 15.5 ms. A design that tolerates a sag of only 0.1 V can use 0.47 µC, which is 470 nC, and that lasts 0.47 ms at 1 mA.
Static discharge and test pulses
The human body model of electrostatic discharge uses a 100 pF capacitor, and at 2,000 V it holds 200 nC, which is 0.2 µC. A larger discharge from a charged plastic object may reach several microcoulombs, though real objects vary. Test generators for surge and discharge standards quote charge in nC or µC for the impulses they apply. When a test report says 0.2 µC and a device specification says 200 nC, they are the same charge, and the page confirms it in a second. The numbers describe a common test model and not a measurement of any person. Charge matters most at an amplifier or logic input. A 0.2 µC discharge into a 10 nF node raises its voltage by Q/C, which is 20 V, enough to damage an unprotected input, while the same charge into a 1 µF node gives only 0.2 V. That is why protection circuits add capacitance or clamp diodes at exposed connectors.
Photodiodes and integrators
A light sensor that integrates photocurrent on a capacitor accumulates charge over the exposure time. A photocurrent of 50 nA over 20 ms gives 1,000 pC, which is 1 nC, or 0.001 µC. At 5 µA over the same time the charge is 100 nC, or 0.1 µC. Integrating converters use this to turn light, or a sensor current, into a number. If the datasheet lists the full-scale charge in microcoulombs while your calculation yields nanocoulombs, the converter keeps the two aligned. Check the exposure time and the unit of current before any conversion, since an error there is larger than any prefix slip.
Going from microcoulombs to nanocoulombs
To convert in the other direction, select microcoulombs as the source and nanocoulombs as the target. A value of 2.2 µC equals 2,200 nC, and 0.05 µC equals 50 nC. Multiply by 1,000. If your meter reads in microcoulombs and your simulation expects nanocoulombs, this is the step to use. A sanity check is that the nanocoulomb number is always the larger of the two. Keep both numbers in your notes when you transfer data between programs, so that you can see which unit each program expects.
Rounding and tolerance
Because the factor is a power of ten, the converted value has the same significant digits as the input. Capacitors have tolerances of 5 or 10 percent, and many are worse for some dielectrics at bias voltage, so the computed charge of a real part is only approximate. Quote two or three digits, such as 2.6 µC for 2,640 nC. Rounding in the page happens at display time, and the underlying result keeps full precision, so repeated conversions do not accumulate error. If you tabulate charges from several capacitors, convert each value first and add them afterward, then round the total once. Adding rounded microcoulomb values can leave a total that differs from the sum of the original nanocoulomb values in the last digit, which is a common reason two reviewers of the same spreadsheet disagree.
Capacitor ratings and discharge hazards
The page converts a charge to another unit. It does not compute capacitor voltage ratings, discharge currents or the energy of a pulse, and it does not determine whether a discharge is hazardous. Use datasheets, standards for electrostatic control and your own design analysis for those questions, and use the converter for consistent numbers.