Capacitor charge next to battery capacity

Batteries are rated in ampere-hours or milliampere-hours, while the charge stored in a small capacitor, a sensor or a static discharge is measured in nanocoulombs. Putting the two in one unit shows how little a capacitor holds compared with even the smallest cell. This page multiplies the nanocoulomb value by about 2.77778e-13 and shows ampere-hours. A reading of 10 nC becomes about 2.78e-12 Ah, a number so small that the main information is its exponent. The page helps students who work through a unit exercise, designers of energy-harvesting circuits who compare a pulse with a battery budget, and anyone who wants to see in one table why a capacitor cannot replace a cell.

Coulombs, hours and the factor 3,600

The coulomb is the SI unit of charge, one ampere-second, and the ampere is fixed through the elementary charge as described in the BIPM SI Brochure. An ampere-hour is one ampere flowing for 3,600 seconds, so 1 Ah = 3,600 C. A nanocoulomb is 10^-9 C, so 1 nC = 10^-9 / 3,600 Ah, about 2.7778 × 10^-13 Ah. The factor combines a power of ten and a division by 3,600. For a check, convert to coulombs first by multiplying by 10^-9, then divide by 3,600. The page does both in one step through its base unit and rounds only the displayed result.

Ten nanocoulombs in ampere-hours

With 10 nC entered, the page shows about 2.7778e-12 Ah. A charge of 100 nC is about 2.7778e-11 Ah, and 5,000 nC, which is 5 µC, is about 1.3889e-9 Ah. In milliampere-hours, which battery labels use, multiply by 1,000: 5,000 nC is about 1.39e-6 mAh. These values are far below anything a battery label states. As a landmark, a 1 mAh battery holds 3.6 C, which is 3.6 billion nanocoulombs, so a charge of 10 nC is under three parts in a billion of one milliampere-hour.

Static discharge and the human body model

Electrostatic discharge tests use a model in which a person is a 100 pF capacitor charged to a few kilovolts. With Q = C × V, 100 pF at 1,000 V holds 100 nC, which is 1 × 10^-7 C. In ampere-hours that is about 2.78e-11 Ah. The charge is minuscule, yet the discharge can reach several amperes for a few nanoseconds and damage a chip, which shows that damage depends on current and voltage, not on total charge. The figures are the standard illustration of the model and are not measurements of any person or device. The page converts the charge only and cannot tell you how much a device can survive.

Pulses and coulomb counting

A fuel gauge chip in a phone or a power tool counts charge by integrating current. A pulse of 10 mA lasting 1 ms transfers 10 µC, which is 10,000 nC, and equals about 2.78e-9 Ah. Added over a day of such pulses, 86,400,000 of them, the total reaches 0.24 Ah, which a battery gauge would register as a real drain. This explains why short pulses still matter: the small numbers add up. Converting a per-pulse charge into ampere-hours lets you compare it with the capacity rating and with the daily budget. The numbers are illustrative and the page performs only the unit conversion.

Capacitors and energy storage

A capacitor of 1 µF charged to 5 V holds 5 µC, or 5,000 nC, which is about 1.39e-9 Ah. The same battery-style figure for a 3,000 mAh phone battery is 3 Ah, or 10,800 C. The battery holds more than two billion times the charge. Charge is not the same as energy, however. The stored energy of the capacitor is half of C × V², here 12.5 µJ, while a battery at 3.7 V and 3 Ah holds about 40 kJ. The page compares charge only, which answers questions such as how long a pulse can be sustained, not how much work can be done. A designer who wants a capacitor to carry a 2 mA load for 10 ms needs 20 µC, which is 20,000 nC, and a capacitor that holds that charge while its voltage falls only slightly, so the capacitance has to be large compared with the charge divided by the allowed voltage drop.

From ampere-hours back to nanocoulombs

To go the other way, select ampere-hours as the source and nanocoulombs as the target. One ampere-hour equals 3.6 × 10^12 nC, and 1 mAh is 3.6 × 10^9 nC. Multiply by 3,600 and by 10^9. The results are long numbers, so exponent form is easiest to read. If you enter the capacity of a coin cell, say 0.225 Ah, the answer is 810 C, or 8.1 × 10^11 nC. Comparing that with a pulse of 1,000 nC shows that the cell could supply about 810 billion such pulses, ignoring all losses. A larger example is a power bank rated at 10,000 mAh, which is 10 Ah, 36,000 C, or 3.6 × 10^13 nC. Rated capacity is also measured at the cell voltage, not at the 5 V output, so a power bank delivers fewer ampere-hours at 5 V than its label states. The charge unit hides that voltage conversion, which is one more reason to check what the label figure refers to.

Reading very small exponents

Results with exponents of minus ten or smaller are easy to misread. 2.78e-12 means 0.00000000000278. The exponent tells you the order of magnitude, which is usually the important part, and the leading digits tell you the detail. When you copy a value into a report, keep it in exponent form and attach the unit. If a result appears as 0 on a spreadsheet, the display format is rounding it away, so switch the cell to scientific format rather than assuming the charge vanished. Programming languages print the same numbers as 2.7777777777777777e-12, with more digits than the input supports, and rounding to the digits of the original reading keeps reports tidy. Ampere-hours of this size appear mainly in textbook comparisons, since no one rates a part in picoampere-hours.

Battery runtime needs load, age and temperature

The page converts a charge between units. It does not calculate battery runtime, discharge efficiency, capacitor leakage or the energy of a pulse, and it does not check any rating. Real batteries depend on temperature, load and age. Use the converter for consistent units and the datasheets for the behavior of actual parts.