Fractional motors and tiny power figures
Horsepower is the traditional rating for motors, pumps and engines in the United States, while electronics and small actuators list their power in milliwatts. Both appear when someone replaces a miniature motor, selects a small fan or compares a hobby motor with a shop tool. A vibrating motor in a phone might draw a few hundred milliwatts. A fractional-horsepower motor on a bench grinder is rated in hundreds of watts. Converting the small figure to horsepower, or the large one to milliwatts, gives you a common scale. The page is for that comparison, and the results are small decimals for most milliwatt inputs, which is expected.
The mechanical horsepower definition
One mechanical horsepower, also called imperial or British horsepower, is 550 foot-pounds-force per second. Using the exact definitions of the foot, the pound and standard gravity, NIST SP 811 gives it as 745.6998715822702 watts, about 745.7 W. In milliwatts, that is 745,699.87 mW. The page applies the formula hp mech = mW × 0.0000013410220896. The factor is long because a milliwatt is a very small part of a horsepower. Do not confuse this unit with the 746 W figure often used for electrical motor ratings, or with the metric horsepower of 735.49875 W, which has its own converter. When a catalog lists only hp without a type, convert with this page first, then compare against a second source if the result matters for a purchase.
What 10 mW comes to
With the default of 10 mW, the page returns 0.0000134102 hp. Written in scientific notation, that is about 1.341 × 10^-5 hp. Other readings: 250 mW gives 0.000335256 hp, and 1,000 mW, which is 1 W, gives 0.00134102 hp. A 500 mW micro motor converts to 0.000670511 hp. These values show why horsepower is rarely used at this scale. Nobody describes a sensor motor in hundred-thousandths of a horsepower. The conversion is useful to confirm a unit when a dataset or an old specification mixes the two systems, or when a program needs every power in one unit.
From horsepower down to milliwatts
The other direction is common for people who start from a motor nameplate. A one-twentieth horsepower motor, typical for a small fan or a pump in a fish tank, is 0.05 hp, which equals 37,284.99 mW or about 37.3 W. A quarter horsepower, used on small workshop tools, is 186,424.97 mW, or 186.4 W. Those watt figures are mechanical output at the shaft. The electrical power the motor draws is higher, since the motor has losses, so use the nameplate current and voltage for any electrical load calculation. The page converts the shaft rating only. For a quick plausibility check, remember that one horsepower is about three quarters of a kilowatt, so a motor listed at 0.5 hp should land near 373 W, which is 372,850 mW. If the result is far from that, the From and To selections are probably reversed.
Mechanical, electrical and metric horsepower
The word horsepower covers more than one unit. Mechanical horsepower is 745.6998715822702 W, the one this page uses. The electrical horsepower used in some motor and generator ratings is defined as 746 W. Metric horsepower, abbreviated PS or CV, is 735.49875 W. The three differ by less than 1.5 percent, which matters little for rough sizing but does for comparing two published ratings. If a specification does not name the type, it is usually either mechanical or metric depending on the country and the product, so check the standard or label. The page names its unit as hp mech, to make the choice visible.
Output power versus input power
A horsepower rating on a motor nameplate states shaft output, so the electrical input is higher by the efficiency loss. For example, a motor with an output of 37.3 W and an efficiency of 60 percent draws about 62 W from the supply. An air compressor, a vacuum cleaner or a power tool may state horsepower on the box in ways that follow marketing practice rather than a measured output. When a consumer product claims peak horsepower, a conversion to watts can help you compare with another model that lists watts, but only if both numbers describe the same thing. Check the test conditions listed in the manual.
Writing 0.0000134102 hp as 1.34 × 10^-5
The result of the default example has many leading zeros, so count digits carefully. Write 0.0000134102 hp as 1.34 × 10^-5 hp if you only need three significant figures. Rounding to a fixed number of decimal places can erase the entire value in a table, turning a small motor into zero horsepower. Keep scientific notation or switch to milliwatts or watts for small values, and use horsepower only for values near one. If you convert back to milliwatts from a rounded horsepower number, expect a small difference from the original input because of the rounding in the middle.
Motor sizing needs torque and speed, not just this conversion
The page converts a power value from one unit to another and nothing more. It does not compute torque, speed, efficiency, starting current or the power a load needs. Horsepower, in this form, is a rate of mechanical work, and it says nothing about whether a motor suits a pump or a fan. For those choices you need the load curve, the duty cycle and the manufacturer data. Use the converter to keep units consistent while you compare ratings, and use the product documents to decide what fits the job. Shop-tool and appliance labels often state peak or locked-rotor figures, which a conversion cannot turn into continuous output, so read the footnotes on the label before comparing two products.
Hobby motors and small appliances
Hobby builders meet this conversion when they choose a motor for a model, a small pump or a camera slider. The motor is listed in watts, milliwatts or sometimes horsepower on older stock, and the supply or battery is listed in volts and amps. A 3 W motor is 3,000 mW, which is 0.00402307 hp. A 20 W fan is 20,000 mW, or 0.0268204 hp. A one-eighth horsepower motor, 0.125 hp, is 93,212 mW, which is about 93.2 W. Putting everything in watts is simplest for design work, and horsepower is useful only to read a label. Remember that the labeled number is shaft power and the electrical draw will be higher.