A billionfold change

Milli is 10⁻³ and pico is 10⁻¹², so the two prefixes differ by a factor of one billion. The formula on the page is pF = mF × 10⁹, which turns the default 10 mF into 10,000,000,000 pF. It is rare to compare these two units directly, but it happens when a design includes both a big energy-storage capacitor and RF or timing parts listed in picofarads. Having the conversion on one page shows how many picofarad-sized parts equal the big one and gives a sense of the scale gap. A mistake of a single digit in this conversion changes the answer tenfold, which is why many engineers prefer to move through an intermediate unit. A student working through a problem set can also use it as an answer check: if a worksheet result in picofarads does not match the page for the same millifarad input, the mismatch tells you to retrace the steps before handing in the work.

Crystal load capacitors

Quartz crystal oscillators need load capacitors that are specified in picofarads, usually between a few and about 30 pF. A crystal rated for a load capacitance of 12 pF is typically matched with two capacitors of around 22 pF each, once stray capacitance is included. Those values are tiny next to a 10 mF supply capacitor on the same board, which is 10 billion picofarads. The page does not choose crystal capacitors or calculate the load, which depends on the layout. The usual rule of thumb is that each of the two capacitors sees the other in series, so two 22 pF parts act like 11 pF, to which the stray capacitance of the board, often a few picofarads, is added. Datasheets for the crystal and the microcontroller give the target load and the recommended procedure. It shows the size of the numbers when parts from the two ends of the range appear in one bill of materials.

Cables and oscilloscope probes

Coaxial cables such as RG-58 have a capacitance of about 100 pF per meter, so a 10 m run contributes around 1,000 pF, which is 1 nF. A typical passive oscilloscope probe presents an input capacitance in the range of 10 to 15 pF to the circuit. These values can load a sensitive node, which is why probes are compensated and why long cables affect fast signals. Converting a value from a datasheet in millifarads to picofarads is rarely needed here, but the page lets you compare a probe's 12 pF with a 10 mF reservoir and see the gap, which is roughly 800 million to one.

Working with tiny millifarad inputs

To get a picofarad result in the range of real RF parts, the millifarad input must be a very small decimal. A capacitance of 100 pF is 0.0000001 mF, and 20 pF is 0.00000002 mF. Typing that many zeros invites errors, so use exponent notation such as 1e-7. If you start from a part marked 22 pF, it is faster to use the picofarad to farad pages than this one. The conversion from millifarads is useful when the starting number is a computed value in millifarads, for example the result of a simulation or a spreadsheet, and you want to read it in picofarads.

How picofarads relate to the neighbors

The prefixes between milli and pico are micro (10⁻⁶) and nano (10⁻⁹). One millifarad is 1,000 µF, 1,000,000 nF and 1,000,000,000 pF. Each rung multiplies by 1,000. A useful memory aid is that 1 nF is 1,000 pF and 1 µF is 1,000 nF, so 1 µF is 1,000,000 pF. When a value looks wrong by a factor of 1,000 or a million, rewrite it at each rung and see which one matches the context. For instance, a capacitor of 100 pF cannot also be 0.1 µF, because 0.1 µF is 100,000 pF.

Ceramic capacitor marking codes

Small ceramic capacitors are often marked with a three-digit code that gives the value in picofarads: the first two digits are the significant figures and the third is the number of zeros. A part marked 104 is 10 followed by four zeros, or 100,000 pF, which is 100 nF or 0.1 µF. A part marked 473 is 47,000 pF, which is 47 nF. A part marked 221 is 22 followed by one zero, or 220 pF, and one marked 102 is 1,000 pF, which is 1 nF. The code is a convenient way to fit a value on a part only a few millimeters across, and it explains why the same capacitor appears as 100 nF in one list and 104 in another. Entering 0.0001 in this page converts 0.0001 mF to 100,000 pF, matching the 104 code. The page does not decode markings, but it confirms conversions you derive from them.

Reading very large results

A result like 10,000,000,000 is easy to misread. The same value is 1 × 10¹⁰ pF, and the page may show it as 1e10. For spreadsheets, enter the exponent form and format the cell to display the whole number, or switch to scientific notation. When you write the value in a document, add the unit in every cell and align the decimal points or exponents. Two numbers in a column that differ by a factor of 1,000 should look different at a glance, and exponents make that happen.

Back to millifarads

Swap the menus to divide by 10⁹. A capacitor of 100 pF equals 0.0000001 mF and 1,000 pF equals 0.000001 mF. The result for a 22 pF crystal capacitor is 0.000000022 mF, a number with seven zeros after the decimal point that is much harder to read than the original value, which is the clearest argument for using the unit that matches the part. These results are so small that the millifarad is clearly the wrong unit for them, and picofarads or nanofarads give a better description. The reverse conversion is useful for checking a calculation done in base units: 100 pF is 1 × 10⁻¹⁰ F, and 0.0000001 mF is also 1 × 10⁻¹⁰ F, so the two forms agree.

Limits of the page

The page converts the unit of a capacitance and nothing more. It does not account for tolerance, temperature coefficient, voltage dependence, parasitic inductance or the stray capacitance of a board, and it does not evaluate installation limits, equipment ratings, protection or compliance. Capacitance values at the picofarad level are sensitive to layout and measurement conditions, so consult data sheets and measure the circuit when precision matters.