Old tables, new numbers

The poise is the CGS unit of dynamic viscosity, named for Jean Léonard Marie Poiseuille, and it stayed in use long after the SI took over. Gas viscosity tables in older handbooks, vacuum technology texts and instrument manuals list air at about 1.81 × 10⁻⁴ P. A modern source gives the same property as 18.1 µPa·s. A reader holding both has to be sure they agree, and this page performs the conversion, so 18.1 µPa·s returns 0.000181 P. That value matches the old tables, which confirms that the two sources describe the same gas under the same conditions, and not two different measurements that merely look alike.

The factor and its origin

One poise is defined as one dyne second per square centimeter, which equals 0.1 Pa·s. A micropascal second is 10⁻⁶ Pa·s, so one poise holds 100,000 µPa·s. The formula is P = µPa·s × 0.00001, and the decimal point moves five places left. A value of 22.3 µPa·s becomes 0.000223 P, and 8.8 µPa·s becomes 0.000088 P. The SI Brochure notes that CGS units such as the poise are outside the SI, though they remain in use in some fields. The default of 10 µPa·s gives 0.0001 P, shown in raw form as 0.00009999999999999999 because of floating-point storage.

Micropoise in old gas tables

Because the poise is large for gases, older tables use the micropoise, 10⁻⁶ P. One micropoise equals 0.1 µPa·s, so a table value of 181 micropoise is 18.1 µPa·s. The default 10 µPa·s is 100 micropoise, or 0.0001 P. When a table lists hydrogen at 88 micropoise and air at 181, the corresponding SI values are 8.8 and 18.1 µPa·s. Converting both ways through this page helps you spot whether a listed number is in poise, micropoise or micropascal seconds, which look alike when printed without a unit. A value near 181 is almost certainly micropoise, and one near 18 is almost certainly µPa·s.

Comparing a table in poise with a data logger in SI

A laboratory may run a gas flow experiment with a modern instrument that reports viscosity in µPa·s and compare it with a classic reference that gives poise. Say the data logger shows 17.6 µPa·s for nitrogen at room temperature. The page converts it to 0.000176 P. The classic table lists 1.76 × 10⁻⁴ P, which is the same value. If they differed by a factor of ten, the culprit would be a misread micropoise entry, since 1 micropoise is 0.1 µPa·s and not 1. Keeping a conversion check on hand avoids rebuilding the lookup each time, and it reveals whether an apparent discrepancy is real or just a unit slip. If the two sources still disagree after conversion, compare the stated temperature and gas purity next, since a few degrees or a trace of humidity moves the value by a fraction of a percent.

Poise, centipoise and the pascal second

The relationships are easy to chain. 1 P equals 100 cP and 0.1 Pa·s. So 1 cP equals 1 mPa·s, 0.01 P and 1,000 µPa·s. Water at 20 °C is about 1 cP, which is 0.01 P and 1,002 µPa·s. The default of 10 µPa·s is 0.01 cP and 0.0001 P. When a source gives a viscosity in poise, converting through pascal seconds is the safest route: multiply by 0.1 to reach Pa·s, then by one million to reach µPa·s. This page shortcuts the last link in that chain for readers who start from micropascal seconds and want poise.

Vacuum technology and rarefied gases

Vacuum references still quote gas properties in CGS units. The viscosity of the residual gas matters when a pressure gauge or a flow element relies on viscous flow, which holds at moderate pressures and gives way to molecular flow at low ones. A text that lists argon at 2.2 × 10⁻⁴ P corresponds to 22 µPa·s. When a modern simulation package expects SI input, the conversion goes in the opposite direction, from poise to Pa·s, but a researcher checking a table against the software often needs the micropascal second figure too. The page handles the direction from µPa·s to P, and swapping the menus reverses it.

Significant digits from historical measurements

Old tables were measured with different methods, such as capillary and oscillating-disk viscometers, and sometimes carry only two or three digits. When you convert a modern value like 18.1 µPa·s to 0.000181 P, you keep three digits. Do not extend the figure to 0.00018100000 P in the hope of matching an old table digit by digit. A difference of a percent or so between sources is normal. A difference of ten percent suggests a different temperature or a different gas composition, for example humid versus dry air. The conversion does not remove that kind of mismatch, but it makes it visible by putting both values in the same unit.

Notation and labeling

Write P for poise and cP for centipoise, and avoid the lowercase p, which reads as a pico prefix or a pressure. Spell out micropoise rather than writing µP, because µP is easy to misread as a micropascal. Put the temperature next to the value. In a table that lists both SI and CGS columns, label each column with its unit and the factor between them, 1 P = 0.1 Pa·s. This stops a later reader from applying the wrong factor. The page uses the P symbol for the poise itself, with no prefix. When you quote a converted number in a report, give both forms once, for example 18.1 µPa·s (0.000181 P), so readers who know only one system can still check the value. If you work from a scanned table, zoom in to confirm whether a figure carries a micro sign or a plain u, because the page treats the number you type as micropascal seconds regardless of how the source printed it.

Keeping viscosity with its temperature

The page converts the unit of a dynamic viscosity. It does not look up gas properties, correct for temperature, or convert to kinematic viscosity in stokes. The multiplication is exact, so differences from a published table come from the digits entered. For centipoise and pascal seconds, use the sibling pages. Keep the original value, its unit and its temperature with every converted figure.