One time unit, two mass units

This conversion changes only the mass unit. A flow of kilograms per second becomes pounds per second by the same factor that converts a kilogram to a pound. That makes it a quick check of vendor data from US manufacturers against calculations in SI, such as pump sizing for water systems, fan and duct design or process flows in a plant with metric instruments. Because the per-second time unit is the same, it is the simplest of the mass-flow conversions on this site and a good one to learn first. The page also converts back, which is useful when a US figure has to enter a metric calculation.

The factor of 2.20462262

The pound is defined as exactly 0.45359237 kg, so 1 kg is 1 ÷ 0.45359237 = 2.20462262 lb. The formula is lb/s = kg/s × 2.20462262, and the reverse is kg/s = lb/s × 0.45359237. Since the reverse factor is the exact definition, going from pounds to kilograms is the cleaner direction. A convenient memory aid is that a kilogram is a bit more than two pounds, so the lb/s number is a little over twice the kg/s number. A result below twice the input signals a slip, such as using the pounds-to-kilograms factor by mistake. Entering 4 kg/s should give 8.82 lb/s, and entering 25 kg/s should give 55.12 lb/s, which are quick spot checks for any other value you try.

The default of 10 kg/s

Ten kilograms per second equals 22.0462 lb/s. A flow of 10 kg/s is large for most buildings but common in industry, such as a cooling water loop or a big air handling system. For orientation, 100 kg/s is 220.462 lb/s, and 1 kg/s is 2.20462 lb/s. The page keeps the full precision of the multiplication, so round your result to the number of significant figures in the input. If you only measured the flow to two figures, then 22 lb/s is the honest answer. Flows from a pump test are usually good to two or three figures at best, because the timing and the weighing each add a small error.

Water flows and gallons per minute

In the US, pump and sprinkler flows are quoted in gallons per minute, but a mass flow in lb/s links to that figure through the weight of water, about 8.34 lb per US gallon. A flow of 1 kg/s of water is 2.20462 lb/s, which is about 15.9 gallons per minute. A garden pond pump moving 0.5 kg/s is therefore 1.1023 lb/s, or close to 8 gpm. Use the converter for the mass step and apply the density of the liquid yourself for the volume step. The weight per gallon changes with temperature and with dissolved solids, so the rule is approximate. For a fountain or a stream feature, a pump curve gives gpm at a stated head, and converting that to lb/s with the water weight lets you compare it with a mass flow from a model. At 20 gpm the water mass flow is about 2.8 lb/s, which is 1.26 kg/s.

Air handling and ductwork

A system moving 0.75 kg/s of air has a mass flow of 1.65347 lb/s. At about 1.2 kg/m³, that is about 0.625 m³/s, or roughly 1,300 cubic feet per minute, since 1 m³/s is about 2,119 cfm. US catalogs for fans and air handlers use cfm for volume, but mass flow is the quantity that matters for heating and cooling loads, because the heat carried depends on mass and not on volume. If a vendor figure in lb/s must be compared with a design in kg/s, use this page to move between them and keep the air density in mind when switching to volume. A coil that cools 0.75 kg/s of air by 10 K removes about 7.5 kW using a specific heat near 1,005 J/(kg·K), and that heat figure follows from the mass flow with no reference to cfm.

Round numbers in pounds

Sometimes it helps to convert the other way and find which SI flow corresponds to a round US number. A flow of 10 lb/s is 4.5359237 kg/s, and 1 lb/s is 0.45359237 kg/s. Entering 4.5359237 kg/s returns 10 lb/s. In a spec, these exact relationships let you state a requirement in both systems without a rounding error: for example, a minimum flow of 4.54 kg/s (10 lb/s). Where the contract is in US units, convert the contract number and keep the original as the reference. An acceptance test then compares a measured flow in kg/s with the contract figure in lb/s through this single factor, and both parties can verify the arithmetic from the exact definition of the pound.

Pound mass in context

The pound in lb/s is a unit of mass, written lbm in thermodynamics and fluid mechanics texts. The pound-force lbf is separate, and the two are linked by gc = 32.174 lbm·ft/(lbf·s²) in US customary calculations. Converting kg/s to lb/s does not involve gc. It matters when you go on to compute a force, such as thrust or momentum flux, from a mass flow in US units, where mixing lbm and lbf is a frequent source of errors. A mass flow of 2 lbm/s at a velocity of 100 ft/s gives a momentum flow of 200 lbm·ft/s², which is 6.22 lbf after dividing by gc. The page covers only the first step of such a chain, the mass flow itself.

Presenting the result

Give both values with units when you document a conversion, for example 10 kg/s (22.05 lb/s). Match decimal places to the least precise number. Tables used by both metric and US readers are easiest to read with the same number of significant figures in both columns. Avoid abbreviating pounds per second as pps, which readers may take to mean something else. In a figure, put the SI unit on the left axis and the US unit on a secondary axis scaled by 2.20462, so both audiences read the same curve. State in the caption that the pound is the avoirdupois pound of mass.

Pump, fan and pipe flow capacity

The page converts a mass flow from one unit to another. It does not calculate installation limits, equipment ratings, protection, material response or compliance, and it does not say whether a pump, fan or pipe can carry the flow you enter.